HomeMy WebLinkAboutTypical Structure Install Latham International — Universal Steel NOTES:
Notes
aL N
The Latham International, inground steel swimming pools are ` N
ntly installed for recreation use as swimming pools in residentiali I
�� L
ons with water circulated through a filter in a closed system. The it --t7
Imply with ANSI/NSPI-5 as Type 0 pools. Feet First
TYPICAL STEP �
e Latham International, inground steel wall swimming pools consist of
II panels, steel frames and supports, vinyl liners and associated C3
ries (e.g., copings, spas, skimmers, filters, plumbing, etc.)Steel wall COPING
Ire comprised of No. 14 gauge (0.066 inch, minimum) steel sheets with TYPICAL STEP
-d coating. Steel frames and supports are comprised of No. 12 guage a Support Assembly STEP ° C3
)ch) cold rolled steel. The vinyl PVC liner is a flexible material with a . CGRANULAR Z
A-FRAME
i thickness of 20 mils (O.Smm). Fasteners are 3/8 inch diameter 1 O PANEL ENDS Pei ° STEP
BRACC SUPPORT u
g, flanged hex, A307 steel bolts, JS500 coated, with matching hex OR 8'-0• O.C. MAX. STEP CHANNELS N O
)pings are extruded, painted aluminum. Steps are a co—extruded UNDISTURBED SOIL ° O U
)rmed sheet of ABS with a weatherable cap. Steps and Spas are 3'-4' •. F ° Q
)rmed sheets of Acrylic with a fiberglass backing. Specifications may CL
+/— 3% per industry standards. The Latham Manufacturing, Inc. ° O BEAM o Q
BOND
polymer swimming pools are only ICC approved and compliant when AR STAKE AT EACH
/ V
EACH BRACE
conjunction with complimenting accessories with the Latham CONCRETE
1 P 9 COLLAR
turing, Inc. identification label. If any Latham Manufacturing, Inc.,
.. .. ........
is used in conjunction with a non—Latham inground swimming pool, TYPICAL BRACE
ICC approval and compliancy is only applicable to the Latham UNDISTURBED EARTH
turing, Inc., product and not the entire entity. INSTALLATION DETAIL BRACE ASSEMBLY
e Latham International, inground steel swimming pools must be
in accordance with the manufacturer's published installation TWO WALL PANELS Support�As STEP
STEP � 0 O
ons. All plumbing, electrical and concrete decking must comply with the � 00 0
effect at the construction site. Clearances of the pools from slopes
observed as set forth in IBC Section 1805.3 or R403.1.7. A barrier N
SEE SECTIONS'A'6'B' STEP CHANNELS PVC PIPE
installed In accordance with IBC Section 3109 Or IRC Section AG105, TYPICAL DECK CROSS SLIP ROD
able. SECTION AND FOOTING PLAN ADJUSTABLE
BRACE Ln
COPING
e pool is designed to remain full of water at all times. The pool may OPTION c d-
lged if the water level is allowed to drop below the skimmer. When Z w Q
ble drawdown is noticed or if it becomes necessary to drain the pool, BOND BEAM C 0
ufacturer or builder must be contacted for instructions. . Reviewed by: O L
B CE STAKE N
I LEVELER
ltion VERTICAL RIH
e--e•MAX.SPACING Columbia Research&Testing
UNDISTURBED EARTH 10140 Starr Road,P.O.Box 9333 Q
ch pool bears a label with the name of Latham International; the POLE ASSEMBLY Windsor,CA 95492 Z L CS
turing plant location (6930 Gettysburg Pike, Fort Wayne, IN 46804); a TYPICAL PANEL Phone/Fax 707-838-1680 Z O LL
for traceability; and the evaluation report number. INSTALLATION DETAIL IAS and ICC/ES Approved Testing Laboratory � � � M on and Design
Stamp: Z O
e swimming pools may be installed without a soil investigation by a CONCRETE DECK H � QO
#12-14!d design professional, subject to the code official's approval, provided PASTE X R
9 P J PP P SELF DRILLING FASTENER S LL N
the following conditions is encountered at the site: ins„o.c.>
COPING
The existence of uncontrollable ground water within the pool EXTRUDED ALUMINUM M
excavation. = O
The existence of uncompacted fill in contact with any portion of the
p001. VINYL LINER(HUNG) n
-~ O
The existence of expansive type soils. v Q
The existence of any soil types with an angle of repose that will not POOL WALL PANEL } N
support the walls of the excavation at desired slopes. �/ > 0)
Danger to adjacent structures posed by the proposed pool location. TYPICAL PICAL CP2 COPING
The existence of any cracks or openings in soil that would not TYPICAL SPILLOVER SPA w 0)
support the pool bedding. V 0
PVC BEAD V M O
ese are generic drawings and not site specific. H S
� R/F WELD cl-
iing/Sliding equipment shall be designed for swimming pools and shall CONCRETE DECK
Iled in accordance with the diving/sliding equipment manufacturer's COPING FLEXIBLE PVC SHEET
tions. Contact Diving/sliding equipment manufacturer for their LINER RETAINER TRACK
tIOT1S. ' • ?`POOL
VINYL LINER(HUNG) WALL R/F WELD
WALL PANEL
FLOOR UGW
TYPICAL TYPICAL VINYL LINER 'hmRNATn NAL
CANTILEVER DECKING CROSS SECTION PAGE i of 2