HomeMy WebLinkAbout233242 - Marquette- Rev 0.pdf-SEALED Penn FUSION
Engineering
August 31, 2023
Cedar Creek Energy
3155 104th Ln NW
Blaine,MN 55449
RE Marquette Residence
6438 Riverview Terrace NE,Fridley,MN 55432
Client Project#:14.0309
PFE Project#: 233242
On behalf of Cedar Creek Energy,Penn Fusion Engineering LLC (PFE)performed a structural analysis of the roof at
the above referenced location.The purpose of our analysis was to determine if the existing roof system is structurally
sufficient to support the new photovoltaic modules in addition to the code required design loads. Our analysis is based
on the information provided by Cedar Creek Energy and is limited only to the areas where the modules are intended to
be placed.
System Specifications
Panel Specs: (57)Rec-420AA PURE-R
Racking System: SNAPNRACK- UR
The modules are to be located on the following roof planes:
Roof
Mounting Member Member Horizontal Sheathing Roofing Roofing
Plane Size Spacing Span Type Layers
1 Truss 24" 38'-1" CDX 1/2" Asphalt Shingles 1
2 Truss 24" 38'-1" CDX 1/2" Asphalt Shingles 1
3 Truss 24" 19'-0" CDX 1/2" Asphalt Shingles 1
4 Truss 24" 28'-6" CDX 1/2" Asphalt Shingles 1
Design Criteri of
Building Code(s) Ground Snow Pq Wind Speed V
• 2021 IBC 50 psf 115 mph
• 2021 International Residential Code
•ASCE 7-16
Analysis Results
7Mounting Max Attachment Rafter
Plane Attachment Hardware Spacing Pass/Fail
1 Snapnrack L-Foot 48" Pass
2 Snapnrack L-Foot 48" Pass
3 Snapnrack L-Foot 48" Pass
4 Snapnrack L-Foot 48" Pass
Penn Fusion Engineering LLC- 152 S. Broad St. - Lansdale, PA 19446-215-361-8040
This office has determined that the existing roof as specified above will meet the structural requirements of the above
referenced codes in addition to the PV load when installed in accordance with the manufacture's instructions.
If you have any questions regarding this analysis, please feel free to contact us.
Best Regards,
Penn Fusion Engineering, LLC
Andrew D. Leone, P.E.
Principal
Digitally signed by
I hereby certify that this plan,specification,or *.pennfusioneng.com
report was prepared by me or under my direct
supervision and that I am a duly Licensed * DN: cn=*. ennfusionen com, o=Penn
Professional Engineer under the laws of the pennfusi p g
State of Minnesota ' Fusion Engineering, LLC,
An A DN R�DOMEN C LEONE email=aleone@pennfusioneng.com,
Print Name:
1=Lansdale, st=PA, c=US
Signature: oneng . com
Reason: This Document is Certified
Date License# 60316 Location: Penn FusionEng.com
Date: 31.08.2023 17:47:44 +0000