Loading...
HomeMy WebLinkAboutPE Sealed Joel Marquette_V2.1_PLANS NEW PHOTOVOLTAIC ROOF MOUNTED SYSTEM - 23.94 KW DC/17.955 KW AC CONTRACTOR 6438 RIVERVIEW TERRACE NE, FRIDLEY, MN 55432 7 CEDAR CREEK NEW PV SYSTEM SPECIFICATIONS DC SIZE:23 9440 KW DC-(STC) SHEET INDEX CEDAR CREEK ENERGY SYSTEM SIZE: 3155 104TH LN NW, BLAINE, AC SIZE: 17.955 KW AC MODULE: (57)REC SOLAR REC420AA PURE-R PV-01 COVER PAGE MINNESOTA, 55449 INVERTER: (57)ENPHASE IQ7X-96-2-US(240V) PV-02 SITE PLAN (E) FENCE 64 1/2 WAY NE (NEAREST CROSS PV-03 ATTACHMENT PLAN&DETAILS STREET 245' APPROX) PV-04 THREE LINE DIAGRAM PHONE-(763)432-5261 PV-04.1 ONE LINE DIAGRAM LIC. NO. -20638279 PV-05 NOTES PV-06 WARNING LABELS 168'-7' PV-07 INSTALLATION RESOURCE APPLICABLE CODES EQUIPMENT DATASHEETS ATTACHED ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: - 2018 INTERNATIONAL BUILDING CODE 13'-9" - 6'-8" LEGEND 2018 INTERNATIONAL RESIDENTIAL CODE — 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL FIRE CODE ---------- PROPERTY LINE 2020 NATIONAL ELECTRICAL CODE n15'-4" FENCE LINE AS ADOPTED BY CITY OF FRIDLEY / 65'-3" n15'-4" ° °° 28'-9" DESIGN CRITERIA �Q PROJECT NAME &ADDRESS ROOF SURFACE TYPE: COMPOSITE SHINGLE JOEL MARQUETTE ROOF FRAMING: 2"X6"TRUSS @ 24"OC ° ° � BUILDING STORY: ONE STORY ° 6438 RIVERVIEW TERRACE NE, GROUND SNOW LOAD: 50 PSF ° FRIDLEY, MN 55432 WIND SPEED: 115 MPH �33'-11' WIND EXPOSURE: B 0 / �� APN#: 153024420101 RISK CATEGORY: II w AHJ: CITY OF FRIDLEY 12'-0" 0 4 1-011 ROOF ACCESS 2-3 UTILITY: XCEL ENERGY PROJECT NOTES �� POINT SYSTEM DETAILS 1.1.1 THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH THE � �� 12'_1" VICINITY MAP DC SIZE:23.940 KW DC-(STC) RELEVANT YEAR OF THE NATIONAL ELECTRIC CODE(NEC),ALL 15 -11 AC SIZE:17.955 KW AC MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS, (57)REC SOLAR REC420AA PURE-R AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY 44'-0 ' (57)ENPHASE IQ7X-96-2-US(240V) HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. _ _ — 1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND THE PV SYSTEM MUST BE INSPECTED PRIOR TO 1 Q'-1" 92'-51 REVISIONS OPERATION 1.1.3 ALL PV SYSTEM COMPONENTS; MODULES, 6438 Riverview Terrace REV DESCRIPTION DATE UTILITY-INTERACTIVE INVERTERS,AND SOURCE CIRCUIT NE,Fridley,MN 55432, w COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN United States PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC AND OTHER GOVERNING CODES NOTE: _~ 1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL I hereby certify that this plan,specification,or 1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV report was prepared by me or under my direct - RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS supervision and that I am a duly Licensed ONLY! REQUIRED BY THE NEC AND AHJ. Professional Engineer under the laws of the SATELLITE MAP SHEET TITLE State of Minnesota 2. ALL TESTING SHALL BE PERFORMED BY SCOPE OF WORK QUALIFIED PERSONNEL, WITH PROPER PERSONAL COVER PAGE 1.2.1 CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND Print Name: ANDREW DOMENIC LEONE SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM. PROTECTIVE EQUIPMENT THE CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTION OF Signature: ��t_L ,-) , - EXISTING ONSITE CONDITIONS TO DESIGN, SPECIFY,AND Date License# 3. THE PRODUCTION METER AND AC DISCONNECT DRAWN DATE 8/16/2023 60316 SHOULD BE LOCATED TOGETHER IN A READILY INSTALL THE ROOF-MOUNTED PHOTOVOLTAIC SYSTEM 6438 Riverview Terrace DRAWN BY DS DETAILED IN THIS DOCUMENT ACCESSIBLE LOCATION WITHIN 10' OF THE MAIN NEaFr�i�dl11 MN 55432, SERVICE METER Unit states SHEET NUMBER SCALE:/N PROPERTY PLAN 4. 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PV-01 / ` PROVIDED FOR THE METERS AND AC DISCONNECT NOTES: NO POSITION, DISTANCE AND CLEARANCE PLAN VIEW TOTAL ROOF AREA: 3578.22 FTZ 1. ROOF ACCESS POINT SHALL NOT BE LEGEND CONTRACTOR LOCATED IN AREAS THAT REQUIRE THE CONCERNS OF OVERHEAD ELECTRIC TOTAL PV ARRAY AREA: 1186.08 FT PLACEMENT OF GROUND LADDERS OVER SERVICE LINES AND/OR OTHER UTILITIES IN TOTAL%OF ROOF COVERED BY PV: 33.15% OPENINGS SUCH AS WINDOWS OR DOORS, 3 " FIRE SETBACKS AND LOCATED AT STRONG POINTS OF RELATION TO THE PV PANELS 18" 7 CEDAR CREEK BUILDING CONSTRUCTION IN LOCATIONS STRUCTURES, PATIO COVERS, AND/OR 64 1/2 WAY NE (NEAREST CROSS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD ADDITIONS BUILT WITHOUT PERMITS TO BE STREET 245' APPROX) =MECHANICAL VENT OBSTRUCTIONS SUCH AS TREE LIMBS, RESOLVED BY A SEPARATE PERMIT. CEDAR CREEK ENERGY O WIRES OR SIGNS. =FLUE/PLUMBING VENT 2. STRUCTURES,PATIO COVERS,AND/OR FTHESITE HAS 24/7 KEYLESS ACCESS TO 0=FENCE LINE 3155 104TH LN NW, BLAINE, ADDITIONS BUILT WITHOUT PERMITS TO BE RS AND UTILITY AC DISCONNECTS. MINNESOTA, 55449 MICROINVERTER(1 PER MODULE) RESOLVED BY A SEPARATE PERMIT. O (57)REC SOLAR REC420AA PURE-R PHONE-(763)432-5261 OMODULES WITH ENPHASE IQ7X-96-2-US LIC. NO. -20638279 1 (240V)UNDER EACH MODULE O (N)JUNCTION BOX(NEMA 3R) O 4 CONDUIT RUN;SURFACE MOUNTED(ACTUAL O CONDUIT RUNS TO BE DETERMINED IN FIELD) 3 5 (E)UTILITY METER(UNDERGROUND SERVICE) METER#:345014681 'O 4 O EXISITNG CT CABINET(INSIDE HOUSE) n ❑ (N)VISIBLE-OPEN TYPE,LOCKABLE,AND 7O READILY ACCESSIBLE FUSED UTILITY AC ROOF 4 DISCONNECT OAC COMBINER PANEL El O PROJECT NAME &ADDRESS ROOF ACCESS POINT O PV PRODUCTION METER JOEL MARQUETTE 6438 RIVERVIEW TERRACE NE, 2 10 MAIN SERVICE PANEL-1 (INSIDE HOUSE) FRIDLEY, MN 55432 LLI APN#: 153024420101 10.1 MAIN SERVICE PANEL-2(INSIDE HOUSE) AHJ: CITY OF FRIDLEY 0 1 hereby certify that this plan,specification,or (N)VISIBLE-OPEN TYPE,LOCKABLE,AND UTILITY: XCEL ENERGY = report was prepared by me or under my direct 11 READILY ACCESSIBLE NON FUSED PHOTOVOLTAIC AC DISCONNECT LL supervision and that I am a duly Licensed SYSTEM DETAILS Q Professional Engineer under the laws of the DC SIZE 23.940 KW DC-(STC) State of Minnesota 12 (N)ENPHASE IQ ENVOY AC SIZE:17.955 KW AC (57)REC SOLAR REC420AA PURE-R N O SLOPE 18° Print Name: ANDREW DOMENIC LEO E (57)ENPHASE IQ7X-96-2-US(240V) - AZIMUTH 260° p Signature: ��_ ROOF 1 MODULE QTY 31 L) Date License# 60316 TRUSS -2"X6"@ 24"O.C. REVISIONS SURFACE TYPE -COMPOSITE SHINGLE SLOPE 18° REV DESCRIPTION DATE AZIMUTH 80° ROOF 2 MODULE QTY -12 _ TRUSS -2"X6"@ 24"O.C. SURFACE TYPE -COMPOSITE SHINGLE SLOPE 18° AZIMUTH 170° ROOF 3 MODULE QTY -6 _ TRUSS -2"X6"@ 24"O.C. 3 ❑E] 44.0" SURFACE TYPE -COMPOSITE SHINGLE SHEET TITLE SLOPE -18' 4 AZIMUTH -1770° SITE PLAN ROOF 4 MODULE QTY -8 ROO TRUSS -2"X6"@ 24"O.C. ____1 T SURFACE TYPE -COMPOSITE SHINGLE DRAWN DATE 8/16/2023 10.1 6 68.1 DRAWN BY DS g 11 N 5 SHEET NUMBER 1'-0" p � SITE PLAN 12 7 \ , PV-02 SCALE:3/32"= 10 9 r V—O� DISTRIBUTED LOAD CALCULATIONS NOTE: LEGEND CONTRACTOR MODULE REC SOLAR REC420AA PURE-R 1. CONTRACTOR/INSTALLER TO VERIFY COMPATIBILITY OF MODULE WEIGHT 47.4 LBS ANY BRANDS OR PRODUCTS SUBSTITUTED OR USED AS -ATTACHMENT POINTS MODULE DIMENSIONS(L"x W') 68.1"x 44.0" ALTERNATES WITHIN ANY BRAND-SPECIFIC SYSTEMS. TOTAL QTY.OF MODULES 57 CONTRACTOR SHALL SUPPLY AND PRESENT I hereby certify that this plan,specification,or _ - RAIL TOTAL WEIGHT OF MODULES 2701.80 LBS CERTIFICATES OF COMPATIBILITY TO THE BUILDING report was prepared by me or under my direct 7 CEDAR CREEK TYPE OF RACKING SNAPNRACK UR-40 RAIL(172") OFFICIAL UPON INSPECTION AS NEEDED. supervision and that I am a duly Licensed -STRUCTURAL MEMBER TYPE OF ATTACHMENT SNAPNRACK ULTRA RAIL UMBRELLA L-FOOT Professional Engineer under the laws of the State of Minnesota DISTRIBUTED WEIGHT OF RACKING 0.5 PSF 2. REFER TO PV MODULE MANUFACTURER'S INSTALLATION TOTAL WEIGHT OF ARRAY 3294.84 LBS INSTRUCTIONS FOR RAIL SPACING SPECIFICATIONS CEDAR CREEK ENERGY AREA OF MODULE 20.81 SOFT. Print Name: ANDREW DOMENIC LEOI�E 3155 104TH LN NW, BLAINE, TOTAL ARRAY AREA 11186.08 SOFT. DISTRIBUTED LOAD 2.78 PSF Signature: MINNESOTA, 55449 ��t.L .T` Date License# 60316 PHONE-(763)432-5261 LIC. NO. -20638279 4'-0"OC ATTACHMENT SPACING 4'-0"OC ATTACHMENT SPACING PROJECT NAME &ADDRESS • • • • JOELMARQUETTE 6438 RIVERVIEW TERRACE NE, STRUCTURAL MEMBER @ 24"OC STRUCTURAL MEMBER @ 24"OC FRIDLEY, MN 55432 APN#: 153024420101 1 .0 TYPICAL ATTACH M ENT PLAN PORTRAIT 1 . 1 TYPICAL ATTACHMENT PLAN LANDSCAPE AHJ: CITY OF FRIDLEY PV-03 SCALE: NTS PV-03 SCALE: NTS UTILITY: XCEL ENERGY SYSTEM DETAILS DC SIZE:23.940 KW DC-(STC) AC SIZE:17.955 KW AC (57)REC SOLAR REC420AA PURE-R (57)ENPHASE IQ7X-96-2-US(240V) PV MODULE REVISIONS / SNAPNRACK INTEGRATED GROUNDING& REV DESCRIPTION DATE MID/END CLAMP PV MODULE / SNAPNRACK ULTRA RAIL SEE ENLARGEDVIEW i� SNAPNRACK L-FOOT / 1(E)COMP SHINGLE ROOF FLASHING SHEET TITLE ATTACHMENT PLAN (E)STRUCTURAL MEMBER MIN.5/16"LAG SCREW W/MIN. 2-1/2"EMBEDMENT INTO & DETAILS STRUCTURAL MEMBER (E)STRUCTURAL MEMBER DRAWN DATE 8/16/2023 DRAWN BY DS 2 ATTACHMENT DETAIL 3 ENLARGED VIEW SHEET NUMBER PV-03 Scale:NTS PV-03 Scale:NTS PV-03 MICROINVERTER SPECIFICATIONS SOLAR MODULE SPECIFICATIONS DER SYSTEM IS AMBIENT TEMPERATURE SPECIFICATIONS CONTRACTOR MANUFACTURER/MODEL# ENPHASE IQ7X-96-2-US(240V) MANUFACTURER/MODEL# REC SOLAR REC420AA PURE-R SINGLE PHASE RECORD LOW TEMP -26°C INPUT POWER RANGE 320W-46OW VMP 50.00V AMBIENT TEMP(HIGH TEMP 2%AVG.) 32°C MIN/MA STARTLACVOVOLTAGE VOLTAGE 33V/79240V( IN IMP 8.40A MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE 7/8" :��' CEDAR CREEK NOMINAL AC VOLTAGE 240V(SINGLE PHASE) VOC 59.40V m� MAX CONT.OUTPUT CURRENT 1.31A ISC 8.89A e"r9y MAX CONT.OUTPUT POWER 315W ITEMP.COEFF.VOC -0.26%/°C MAX MODULES PER STRING 112(12 MICROINVERTERS) TO UTILITY GRID L1 L2N CEDAR CREEK ENERGY LINE (E)BI-DIRECTIONAL 3155 104TH LN NW, BLAINE, UTILITY METER,400A M > RATED,1-PHASE,3-W, MINNESOTA, 55449 120V/240V ROMEX CAN BE USED IN LIEU OF CONDUIT FOR INTERIOR BUILDING AND ATTIC LOAD (UNDERGROUND RUNS ONLY.DO NOT USE ROMEX IN CONDUIT OR OUTDOOR ENVIRONMENTS. POC/RPA SERVICE) PHONE-(763)432-5261 10A OR 15A BREAKER IS (N)VISIBLE-OPEN TYPE, LIC. NO. —20638279 SUITABLE FOR USE LOCKABLE,AND READILY (N)VISIBLE-OPEN TYPE, (E)CT CABINET, N 100A DEDICATED LOCKABLE,AND READILY 400A RATED REC SOLAR REC420AA PURE-R (INSTALLED w NPMns ENCLOSURE) ( ) ACCESSIBLE PHOTOVOLTAIC (N)XCEL OWNED DER ACCESSIBLE UTILITY AC LOAD SIDE (INSIDE HOUSE io cnrewnv PV SUBPANEL, AC DISCONNECT 100A PRODUCTION METER DISCONNECT 100A FUSED, CONNECTION ) NEMA3R,UL LISTED, NON-FUSIBLE,1-PHASE, 1-PHASE,3-WIRE, 12 MICROINVERTERS IN STRING 1 (2)900A 0V,NEMPHASE, d7l wrz Ess 240V 3-WIRE,240V,NEMA3R, LOAD SIDE coMMs NEMA 3R,UL LISTED 3-WIRE 240V,NEMA 3R,UL UL LISTED INTERCONNECTION 120V/240V,200A RATED LISTED AT CT CABINET ENPHASE Q L1 L1 L1 L1 L1 CABLE(S) L2 L2 L2 L2 L2 I I EXISTING GROUNDING 15A/2P N N N N N 12 MICROINVERTERS IN STRING 2 I (N)JUNCTION BOX T GEC_ ELECTRODE SYSTEM TO 600 V.NEMA 3R G LINE G G G LINE G EARTH UL LISTED LINE — L1 20A/2P 2 2 L2 L1 2 2 12 MICROINVERTERS IN STRING 3 I L1 20A 2P L2 M L1 E L1 20A/2P LOA LOAD LOA (E)MAIN BREAKER TO (E)MAIN BREAKER TO G 20A/2P 240V,2HOUSE(FORMSP-1) HOUSE240V,2 OA/2PFOR -z) PROJECT NAME &ADDRESS 12 MICROINVERTERS IN STRING 4 L. zaov,zooArzP zaov,zooAizP 0 (E)MAIN SERVICE PANEL-1 (E)MAIN SERVICE PANEL-2 200A RATED, 200A RATED,1-PHASE,240V JOEL MARQUETTE (N)JUNCTION BOX 1-PHASE,240V 600 V,NEMA 3R 1 20Al2P (INSIDE HOUSE) (INSIDE HOUSE) UL LISTED 6438 RIVERVIEW TERRACE NE, L1 9 MICROINVERTERS IN STRING 5 N N FRIDLEY, MN 55432 L1 G G G APN#: 153024420101 G AHJ: CITY OF FRIDLEY ENPHASE IQ7X-96-2-US(240V) UTILITY: XCEL ENERGY MICROINVERTERS ONE UNDER EACH PANEL #6AWG BARE CU THE METER SOCKET INSTALLED HAS A LEVER BYPASS HANDLE PV UTILITY DISCONNECTS ARE - LOCATED WITHIN 10' OF SYSTEM DETAILS MAIN SERVICE/BILLING METER VISIBLE,LOCKABLE, DC SIZE:23.940KWDC-(STC) AC SIZE:17.955 KW AC READILY ACCESSIBLE AND 24/7 ACCESS (57)REC SOLAR REC420AA PURE-R (57)ENPHASE IQ7X-96-2-US(240V) NOTE: 1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY! 2. ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONAL PROTECTIVE EQUIPMENT 3. THE PRODUCTION METER AND AC DISCONNECT SHOULD BE LOCATED TOGETHER IN A READILY ACCESSIBLE LOCATION REVISIONS WITHIN 10' OF THE MAIN SERVICE METER PHOTOVOLTAIC AC 4. 2417 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED FOR THE METERS AND AC DISCONNECT DISCONNECT REV DESCRIPTION DATE 5. NOTE ALL THE APPLICABLE NEC CODES 6. SHOW ALL THE SYSTEMS INCLUDING STORAGE, EXISTING AND NEW(IF APPLICABLE) LABEL LOCATION:AT AC DISCONNECT 7. SERVICES<320A WILL USE SELF-CONTAINED MAIN SERVICE METERS. 320A SERVICES MUST INDICATE WHETHER THE METERING WILL BE SELF-CONTAINED OR TRANSFORMER METERED.ALL SERVICES 400A OR GREATER MUST BE UTILITY AC DISCONNECT TRANSFORMER METERED 8. PRODUCTION METER LOCATED WITHIN 10 FT OF METER LABEL LOCATION:AT AC DISCONNECT 9. WIRES LOCATED IN READILY ACCESSIBLE LOCATIONS SHALL BE GUARDED PER NEC 690.31(A) SHEET TITLE 10. CONDUIT TO BE UL LISTED FOR WET LOCATIONS AND UV PROTECTED (EX. -EMT,PVC OR RMC)*FMC MAY BE USED IN PHOTOVOLTAIC INDOOR APPLICATIONS WHERE PERMITTED BY NEC ART. 348 SYSTEM CONNECTED THREE LINE 11. VISIBLE LOCKABLE AND LABELED DISCONNECT IS LOCATED WITHIN 10FT OF METER DIAGRAM 12. THE INVERTERS ARE UL1741 CERTIFIED LABEL LOCATION:AT THE MAIN BILLING METER DESCRIPTION FORMULA RESULT DRAWN DATE 8/16/2023 PV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25=(57 x 1.31)A x 1.25 93.34A (SELECTED OCPD = 100A) DRAWN BY DS TEMP QTY OF CURRENT CONDUIT MINIMUM CONDUCTOR CONDUCTOR REQUIRED CIRCUIT ADJUSTED NEUTRAL EXPECTED WIRE GAUGE& GROUND WIRE WIRE ID DERATE CARRYING CONDUIT SIZE AMPACITY @ AMPACITY @ CONDUCTOR CONDUCTOR CONDUCTOR WIRE TEMP(°C) (90°C) CONDUCTORS FILL DEBATE (TBD ON SITE) TYPE 90°C(A) 75°C(A) AMPACITY(A) AMPACITY @ 90°C(A) SIZE&TYPE SIZE&TYPE SHEET NUMBER 1 32 0.96 6 0.8 3/4"METAL #10 THWN-2 40 35 19.65 30.72 NONE #10 THWN-2 PV-04 1A 32 0.96 4 0.8 3/4"METAL #10 THWN-2 40 35 19.65 30.72 NONE #10 THWN-2 2 32 0.96 2 1 1"METAL #3 THWN-2 115 100 93.34 110.40 #3 THWN-2 #8 THWN-2 MICROINVERTER SPECIFICATIONS SOLAR MODULE SPECIFICATIONS DER SYSTEM IS AMBIENT TEMPERATURE SPECIFICATIONS CONTRACTOR MANUFACTURER/MODEL# ENPHASE IQ7X-96-2-US(240V) MANUFACTURER/MODEL# REC SOLAR REC420AA PURE-R SINGLE PHASE RECORD LOW TEMP -26°C INPUT POWER RANGE 320W-46OW VMP 50.00V AMBIENT TEMP(HIGH TEMP 2%AVG.) 32°C MIN/MAX START VOLTAGE 33V/79.5V IMP 8.40A NOMINAL AC VOLTAGE 240V(SINGLE PHASE) VOC 59.40V MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE 7/8" 7 CEDAR CREEK MAX CONT.OUTPUT CURRENT 1.31A ISC 8.89A MAX CONT.OUTPUT POWER 1315W ITEMP.COEFF.VOC -0.26%/°C MAX MODULES PER STRING 112(12 MICROINVERTERS) TO UTILITY GRID N CEDAR CREEK ENERGY L 1 L2 (E)BI-DIRECTIONAL 3155 104TH LN NW, BLAINE, LINE UTILITY METER,400A MINNESOTA, 55449 M RATED,1-PHASE,3-W, 120V/240V ROMEX CAN BE USED IN LIEU OF CONDUIT FOR INTERIOR BUILDING AND ATTIC LOAD (UNDERGROUND PHONE-(763)432-5261 RUNS ONLY.DO NOT USE ROMEX IN CONDUIT OR OUTDOOR ENVIRONMENTS. POC/RPA SERVICE) LIC. NO. -20638279 10A OR 15A BREAKER IS (N)VISIBLE-OPEN TYPE, SUITABLE FOR USE LOCKABLE,AND READILY (N)VISIBLE-OPEN TYPE, (E)CT CABINET, N 100A DEDICATED LOCKABLE,AND READILY 400A RATED REC SOLAR REC420AA PURE-R (INSTALLED IN NESA 3R ENCLOSURE) (N) ACCESSIBLE PHOTOVOLTAIC (N)XCEL OWNED DER ACCESSIBLE UTILITY AC LOAD SIDE INSIDE HOUSE PV SUBPANEL, AC DISCONNECT 100A PRODUCTION METER CONNECTION ( ) IQ GATE NAY DISCONNECT 100A FUSED, NEMA 3R,UL LISTED, NON-FUSIBLE,1-PHASE, 1-PHASE,3-WIRE, 2 900A 0V,NEMA 3R,USES,1 E, db 12 MICROINVERTERS IN STRING 1 wiR Ess 240V 3-WIRE,240V,NEMA 3R, NEMA 3R,UL LISTED 3-WIRE 240V,NEMA 3R,UL LOAD SIDE coimims UL LISTED 120V/24OV,200A RATED LISTED INTERCONNECTION ENPHASE Q L1 L1 L1 L1 L1 AT CT CABINET CABLE(S) L2 L2 L2 L2 L2 15A/2P N N N N N EXISTING GROUNDING 12 MICROINVERTERS IN STRING 2 I (N)JUNCTION BOX GEC- ELECTRODE SYSTEM TO 600 V,NEMA 3R T G LINE G G G LINE G EARTH UL LISTED LINE L1 20A/2P 2 2 L2 L1 2 2 L2 12 MICROINVERTERS IN STRING 3 I L1 20A/2P L2 L2 M L1 E Ll 20A/2P LOAD LOAD LOAD �+�+L2 HOUSE MAIN BREAKER TO HODSMAIN BREAKER TO PROJECT NAME q ADDRESS HOUSE(FOR MSP-1) HOUSE(FOR MSP-2) R Ot R 12 MICROINVERTERS IN STRING 4 L. G 20A/2P 240 V,200w21P 240 V,200A/21P 6-1 (E)MAIN SERVICE PANEL-1 (E)MAIN SERVICE PANEL-2 JOEL MARQUETTE N JUNCTION BOX 200A RATED, 200A RATED,1-PHASE,240V ( ) 1 20A/2P 1-PHASE,240V (INSIDE HOUSE) 600V,NEMA 3R 6 (INSIDEHOUSE) 6 6438 RIVERVIEW TERRACE NE, _ UL LISTED L1 N FRIDLEY, MN 55432 9 MICROINVERTERS IN STRING 5 L2 N N APN#: 153024420101 C G G L1 Lz L AHJ: CITY OF FRIDLEY G UTILITY: XCEL ENERGY ENPHASEIQ7X-96-2-US(240V) =4 THE METER SOCKET INSTALLED MICROINVERTERS ONE UNDER EACH PANEL #6AWG BARE CU HAS A LEVER BYPASS HANDLE SYSTEM DETAILS PV UTILITY DISCONNECTS ARE - LOCATED WITHIN 10' OF DC SIZE:23.940KWDC-(STC) MAIN SERVICE/BILLING METER VISIBLE,LOCKABLE, AC SIZE:17.955KWAC (57)REC SOLAR REC420AA PURE-R READILY ACCESSIBLE AND 24/7 ACCESS (57)ENPHASE IQ7X-96-2-US(240V) NOTE: 1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY! 2. ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONAL PROTECTIVE EQUIPMENT 3. THE PRODUCTION METER AND AC DISCONNECT SHOULD BE LOCATED TOGETHER IN A READILY ACCESSIBLE LOCATION REVISIONS WITHIN 10' OF THE MAIN SERVICE METER PHOTOVOLTAIC AC 4. 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED FOR THE METERS AND AC DISCONNECT DISCONNECT REV DESCRIPTION DATE 5. NOTE ALL THE APPLICABLE NEC CODES 6. SHOW ALL THE SYSTEMS INCLUDING STORAGE, EXISTING AND NEW(IF APPLICABLE) LABEL LOCATION:AT AC DISCONNECT 7. SERVICES<320A WILL USE SELF-CONTAINED MAIN SERVICE METERS. 320A SERVICES MUST INDICATE WHETHER THE METERING WILL BE SELF-CONTAINED OR TRANSFORMER METERED.ALL SERVICES 400A OR GREATER MUST BE UTILITY AC DISCONNECT TRANSFORMER METERED 8. PRODUCTION METER LOCATED WITHIN 10 FT OF METER LABEL LOCATION:AT AC DISCONNECT 9. WIRES LOCATED IN READILY ACCESSIBLE LOCATIONS SHALL BE GUARDED PER NEC 690.31(A) SHEET TITLE 10. CONDUIT TO BE UL LISTED FOR WET LOCATIONS AND UV PROTECTED (EX. -EMT,PVC OR RMC)"FMC MAY BE USED IN PHOTOVOLTAIC INDOOR APPLICATIONS WHERE PERMITTED BY NEC ART. 348 SYSTEM CONNECTED ONE LINE 11. VISIBLE LOCKABLE AND LABELED DISCONNECT IS LOCATED WITHIN 10FT OF METER DIAGRAM 12. THE INVERTERS ARE UL1741 CERTIFIED LABEL LOCATION:AT THE MAIN BILLING METER DESCRIPTION FORMULA RESULT DRAWN DATE 8/16/2023 PV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25=(57 x 1.31)A x 1.25 93.34A (SELECTED OCPD =100A) DRAWN BY DS TEMP QTY OF CURRENT MINIMUM CONDUCTOR CONDUCTOR REQUIRED CIRCUIT ADJUSTED NEUTRAL EXPECTED CONDUIT WIRE GAUGE& GROUND WIRE WIRE ID DERATE CARRYING CONDUIT SIZE AMPACITY @ AMPACITY @ CONDUCTOR CONDUCTOR CONDUCTOR WIRE TEMP(°C) (90°C) CONDUCTORS FILL DERATE (TBD ON SITE) TYPE 90°C(A) 75°C(A) AMPACITY(A) AMPACITY @ 90°C(A) SIZE&TYPE SIZE&TYPE SHEET NUMBER 1 32 0.96 6 0.8 3/4"METAL #10 THWN-2 40 3.5 19.6.5 30.72 NONE #10 THWN-2 P V/_04. 1 IA 32 0.96 4 0.8 3/4"METAL #10 THWN-2 40 35 19.65 30.72 NONE #10 THWN-2 2 32 0.96 2 1 1"METAL #3 THWN-2 115 100 93.34 110.40 #3 THWN-2 #8 THWN-2 GENERAL NOTES CONTRACTOR SITE NOTES GROUNDING NOTES INTERCONNECTION NOTES per'M C E D A R CREEK 2.1.1 A LADDER WILL BE IN PLACE FOR INSPECTION IN ACCORDANCE 2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR 2.7.1 LOAD SIDE INTERCONNECTION SHALL BE IN eLeegu WITH OSHA REGULATIONS. THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TO THE ACCORDANCE WITH NEC 705.12. 2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS ELEMENTS SHALL BE RATED FOR SUCH USE. 2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTER SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE 2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE CONTINUOUS OUTPUT MAY NOT EXCEED 120 PERCENT OF CEDAR CREEK ENERGY BATTERIES. WITH NEC 690.43 AND NEC TABLE 250.122. BUSBAR RATING PER NEC 705.12. 3155 104TH LN NW, BLAINE, 2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY 2.5.3 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND 2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) MINNESOTA, 55449 PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCE WITH OUTPUT CIRCUIT CURRENT AND THE RATING OF THE 2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING NEC 250.134 AND 250.136(A). OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL PHONE-(763)432-5261 AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED IN 2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED IN NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE LIC. NO. -20638279 ACCORDANCE WITH SECTION NEC 110.26. ACCORDANCE WITH NEC 690.45 AND INVERTER BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE 2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MANUFACTURER'S INSTALLATION PRACTICES LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED 2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN IN SOURCE OCPD IN ACCORDANCE WITH NEC 705.12. MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT SERVES TO PROTECT THE BUILDING OR STRUCTURE. 2.5.6 THE GROUNDING CONNECTION TO A MODULE SHALL BE COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT PROTECTION DEVICES SHALL NOT EXCEED AMPACITY OF EQUIPMENT LOCATIONS INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. BUSBAR. HOWEVER, THE MAIN OVERCURRENT PROTECTION 2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS IN 2.5.7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, DEVICE MAY BE EXCLUDED IN ACCORDANCE WITH NEC ACCORDANCE WITH NEC 110.26. SHALL BE COLORED GREEN OR MARKED GREEN IF#4 AWG OR 705.12. 2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE LARGER PER NEC 250.119 2.7.5 FEEDER TAP INTERCONNECTION (LOAD SIDE) IN RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY 2.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC ACCORDANCE WITH NEC 705.12. NEC 690.31 (A),(C) AND NEC TABLES 310.15 (13)(2)(A) AND 310.15 (13)(3)(C). 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS 2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCE 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE WITH TO NEC 705.12 WITH SERVICE ENTRANCE MODULES IN ACCORDANCE WITH NEC 690.34. SYSTEM PROVIDED IN ACCORDANCE WITH NEC 250, NEC 690.47 CONDUCTORS IN ACCORDANCE WITH NEC 230.42. PROJECT NAME &ADDRESS 2.2.4 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE AND THE AHJ. 2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL JOEL MARQUETTE 2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED 690.41(13)(1)AND (2) TO REDUCE FIRE HAZARDS FASTENING PER NEC 705.12. 6438 RIVERVIEW TERRACE NE, PERSONNEL IN ACCORDANCE WITH NEC APPLICABLE CODES. FRIDLEY, MN 55432 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED DISCONNECTION AND OVERCURRENT PROTECTION NOTES FOR OUTDOOR USAGE WHEN APPROPRIATE. 2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT APN#: 153024420101 WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING AHJ: CITY OF FRIDLEY STRUCTURAL NOTES ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED "LINE UTILITY: XCEL ENERGY 2.3.1 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED IN SIDE" (TYPICALLY THE UPPER TERMINALS). ACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION MANUAL. 2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY SYSTEM DETAILS TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH DC SIZE:23.940 KW DC-(STC) AC SIZE:17.955 KW AC RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER 2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLE (57)REC SOLAR REC420AA PURE-R EDGE OF THE ARRAY/SUBARRAY, IN ACCORDANCE WITH RAIL BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO (57)ENPHASE IQ7X-96-2-US(240V) MANUFACTURER'S INSTALLATION PRACTICES. REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN 2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S ACCORDANCE WITH 690.12 SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & 2.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO REVISIONS SEALED PER LOCAL REQUIREMENTS. NEC 690.8, 690.9, AND 240. REV DESCRIPTION DATE 2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED 2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TO A AND SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S) IN LICENSED CONTRACTOR. ACCORDANCE WITH NEC 110.3(B). 2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO 2.6.6 IF REQUIRED BY THE AHJ, SYSTEM WILL INCLUDE GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING ARC-FAULT CIRCUIT PROTECTION IN ACCORDANCE WITH NEC MANUFACTURER OR PROFESSIONAL ENGINEERING GUIDANCE. 690.11 AND UL1699B. 2.3.5 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. SHEET TITLE WIRING & CONDUIT NOTES NOTES 2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON DRAWN DATE 8/16/2023 MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. DRAWN BY DS 2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC SHEET NUMBER 2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC 2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING PV-05 OR LABELING PER NEC AWARNING SOLAR PV SYSTEM EQUIPPED PHOTOVOLTAIC AC CONTRACTOR ELECTRICAL SHOCK HAZARD WITH RAPID SHUTDOWN DISCONNECT LABEL LOCATION:AT AC DISCONNECT 017 CEDRR CREEK e"'9'/ TERMINALS ON THE LINE AND TURN RAPID SHUTDOWN UTILITY AC DISCONNECT LOAD SIDES MAY BE ENERGIZED SWITCH TO THE So gRE EAR, "OFF"POSITION TO IN THE OPEN POSITION SHUT DOWN PV SYSTEM CEDAR CREEK ENERGY LABEL LOCATION:AT AC DISCONNECT LABEL LOCATION:COMBINER PANEL,AC S AND REDUCE HOCK HAZARD 3155 104TH LN NW, BLAINE, DISCONNECT,POINT OF INTERCONNECTION IN THE ARRAY PHOTOVOLTAIC MINNESOTA, 55449 PER CODE:NEC 706.15(C)(4),NEC 690.13(B) SYSTEM CONNECTED 911111111111111 LABEL LOCATION:AT THE MAIN BILLING METER PHONE-(763)432-5261 AVFARNIN LABEL LOCATION MAIN SERVICE DISCONNECT LIC. NO. -20638279 PER CODE:NEC 690.56(C) TURN OFF PHOTOVOLTAIC AC MAIN PHOTOVOLTAIC DISCONNECT PRIOR TO SYSTEM DISCONNECT WORKING INSIDE PANEL LABEL LOCATION: MAIN SERVICE DISCONNECT,UTILITY METER PER CODE:NEC 690.13(B) LABEL LOCATION:COMBINER PANEL(S), MAIN SERVICE DISCONNECT PER CODE:NEC 110.27(C),OSHA 1910.145(f)(7) RAPID PHOTOVOLTAIC POWER SOURCE LABEL LOCATION:DC CONDUIT/RACEWAYS LABEL LOCATION:RSD INITIATION DEVICE,AC DISCONNECT PER CODE:NEC 690.31(D)(2) PER CODE:NEC 690.56(C)(2) SOLAR LABEL LOCATION:DC CONDUIT/RACEWAYS A CAUTION PER CODE:NEC 690.31(D)(2) PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED LABEL LOCATION:MAIN SERVICE DISCONNECT PROJECT NAME &ADDRESS DISCONNECTPHOTOVOLTAIC SYSTEM AC PER CODE:NEC 705.12(D),NEC 690.59 JOEL MARQUETTE RATED AC OUTPUT CURRENT: 74.67 A DO NOT DISCONNECT 6438 RIVERVIEW TERRACE NE, NOMINAL A OPERATING PRA A VOLTAGE: A 240 UNDER LOAD A, FRIDLEY, MN 55432 LABEL LOCATION:AC DISCONNECT/POINT OF INTERCONNECTION LABEL LOCATION:MAIN SERVICE DISCONNECT APN#: 153024420101 PER CODE:NEC 690.54 PER CODE:NEC 690.15(B)&NEC 690.33(D)(2) CAUTION MAXIMUM DC VOLTAGE AHJ: CITY OF FRIDLEY AWARNING DUAL POWER SOURCE MULTIPLE SOURCES OF POWER. UTILITY: XCEL ENERGY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM POWER TO THIS BUILDING IS ALSO SUPPLIED SYSTEM DETAILS LABEL LOCATION:MAIN SERVICE DISCONNECT,PRODUCTION/NET METER OF PV SYSTEM DC SIZE:23.940 KW DC-(STC) PER CODE:NEC 690.59,705.12(C) FROM THE FOLLOWING SOURCES WITH (AC 57)RSIZE:9OLARKW AC EC4 LABEL LOCATION:DC DISCONNECT/INVERTER/PV DIST. (57)REC SOLAR REC420AA PURE-R EQUIPMENT PER CODE:NEC690.53 DISCONNECTS LOCATED AS SHOWN: ADDRESS: 6438 RIVERVIEW TERRACE NE, FRIDLEY, MN 55432 DISCONNECT AWARNING REVISIONS LABEL LOCATION:AC DISCONNECT ELECTRICAL SHOCK HAZARD REV DESCRIPTION DATE PER CODE:NEC 690.13(B) WARNING TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IS EQUIPMENT FED BY MULTIPLE IN THE OPEN POSITION SOURCES: DC VOLTAGE IS ALWAYS PRESENT WHENITTH OAL RATING OF ALL OVERCURRENT SOLAR MODULES ARE EXPOSED TO SUNLIGHT DEVICES EXCLUDING MAIN POWER I SHEET TITLE SUPPLY SHALL NOT EXCEED AMPACITYOF BUSBAR LABEL LOCATION:DC DISCONNECT PER CODE:NEC 690.13(B) WARNING LABELS LABEL LOCATION:AC DISCONNECT PER CODE:NEC 705.12(B)(3)(3) SDI. WARNING MAIN SERVICE PANEL-1 DRAWN DATE 8/16/2023 (INSIDE HOUSE) POWER SOURCE OUTPUT LABEL LOCATION:PV METER MAIN SERVICE PANEL-2 DRAWN BY DS CONNECTION. DO NOT RELOCATE (INSIDE HOUSE) THIS OVERCURRENT DEVICE. AC COMBINER PANEL UTILITY METER SHEET NUMBER LABEL LOCATION:POINT OF INTERCONNECTION CT CABINET INSIDE HOUSE IQ ENVOY PV-06 AC DISCONNECT PER CODE:NEC 705.12(B)(3)(2) AC DISCONNECT PV METER A B C D E F REFERENCE ONLY as CONTRACTOR 7 CEDRR CREEK 1 N e-lwg'/ � -411 CEDAR CREEK ENERGY 19 -101 20 3155 104TH LN NW, BLAINE, MINNESOTA, 55449 2 PHONE-(763)432-5261 LIC. NO. -20638279 3 0 ---J**"\ '0 15'-7" O 4 ROOF 4 P O PROJECT NAME &ADDRESS JOELMARQUETTE 5 6438 RIVERVIEW TERRACE NE, Lu FRIDLEY, MN 55432 C� APN#: 153024420101 0 2 AHJ: CITY OF FRIDLEY 6 ILL UTILITY: XCEL ENERGY 0 SYSTEM DETAILS Z DC SIZE:23.940 KW DC-(STC) N' LL AC SIZE:17.955 KW AC O (57)REC SOLAR REC420AA PURE-R 0 (57)ENPHASE IQ7X-96-2-US(240V) ILL 7 REVISIONS REV DESCRIPTION DATE 8 ❑❑ 81_^11 R� �} SHEET TITLE INSTALLATION 9 RESOURCE DRAWN DATE 8/16/2023 DRAWN BY DS 10 SHEET NUMBER PV-07 **DIMENSIONS ARE 2D (FLAT) w. REE ALPHA PURER 5ERIE5 RE C �,�•, •���'j SOLAR'S MOST TRUSTEDREC PROOIJET SPEEIREATIONS , ,. O TRUSTED GENERAL DATA 880[34b] 425nen Cell type: 80 half-cut REC bifacial,heterojunction cells with , YP ' lead-f ree,gapless technology T ■ ■ T Y j 0.13in(3.2mm)solarglasswithanti-reflectivesurfacetreatment 1 11 ° REC ALPHA Glass: in resistant tpoly with 102-1 Backsheet: Highly resistant polymer(black) 17M[6n 1700[671 - Frame: Anodized aluminum(black) 8 - PURER SERIES -4 + 4-part,4 bypass diodes,lead-free 1UnCt10n box: IP68 rated,in accordance with IEC 62790 5 Staubli MC4 PV-KBT4/KST4(12 AWG) Connectors: [1o.;;°» � j'•• _ A �I in accordance with lEC 62852,IP68 only when connected „- - PROMET 5PEO EATIO' 5 Cable: 12AWG(4mmz)PVwire,67+67in(1.7+1.7m e 205 MS JAI in accordance with EN 50618 Dimensions: 68.1 x 44.0 x 1.2 in(20.77 ft2)/1730 x 1118 x 30 mm(1.93[riz) 30.9] 594t3[23At0.12 3.5 Weight: 47.4lbs(21.5 kg) Origin: Made in Singapore Measurements in inches Jmm] too ELECTRICAL DATA Product Code*:RECxxxAA PURE-R CERTIFICATION5 Power Output-P.gx(Wp) 400 410 420 430 IEC61215:2016,IEC61730:2016,161730 1► �- Watt Class Sorting-(W) 0/+10 0/+10 0/+10 0/+10 IEC62804 PID IEC61701 Salt Mist Nominal Power Voltage-V.pp(V) 48.8 49.4 50.0 50.5 IEC62716 Ammonia Resistance ?� U Nominal Power Current-lm�(A) 8.20 8.30 8.40 8.52 FILL61730 Fire TypeClass2 v~i IEC 62782 Dynamic Mechanical Load 1< Open Circuit Voltage-Voc(V) 58.9 59.2 59.4 59.7 IEC61215-2:2016 Hailstone(35mm) Short Circuit Current-Isr(A) 8.80 8.86 8.91 8.97 IEC62321 Lead-freeacc.to RoHS EU 863/2015 Power Density(W/ftz) 19.3 19.7 20.2 20.7 15014001,ISO9001,IEC 45001,IEC 62941 Panel Efficiency(%) 20.7 21.2 21.8 22.3 0 EIV� C C Ed tv Power Output-PmA.(Wp) 305 312 320 327 enek ` Lea/a. Nominal Power Voltage-VMm(V) 46.0 46.6 47.1 47.6 TEMPERATURE RATINGS* F �r Nominal Power Current- 6.64 6.70 6.80 6.88 NominalModule Operating Temperature: 44°C(±2°C) Z Open Circuit Voltage-Voc(V) 55.5 55.8 56.0 56.3 Temperature coefficient of PH,,,: -0.24%/°C �. Short Circuit Current-Isc(A) 7.11 7.16 7.20 7.24 Temperature coefficient ofVot: -0.24%/'C -. -. Values at standard testconditions(STC:air massAM1.5,irradiance,10.75W/sgft()000W/m'),temperature77°F(25°C),based on a production spread Temperature coefficient ofl : 0.04%/°C with atolerance of P,,Mx,Vim&Isr i'i%within one watt class.Nominal module operatingtemperature(NMOT:airmassAM 1.5,irradiance 800 W/m, sc temperature 68°F(20°C�wIlspeed 33 ft/s(1 m/sG*Wherexxx indicates the nominal power class(P,4,x)at STC above. 'The temperature coefficients stated are linear values MAXIMUM RATINGS WARRANTY DELIVERY INFORMATION Z 9 A MODULE EURRENTLOperationaltemperature; -40...+85°C Standard RECProTrust LPanels per pallet; 33 - .. . . S stemvolta e: 1000V Installedbyan REC Panels er40ftGP h' hcubecontainer.. 858(26 allets) Y g No Yes Yes p / p � � Certified Solar Professional s Test load(front): +7000Pa(1461b5/ft2 System Size All <25 kW 25-500 k )' Panels per 53 fttruck: 858(26 pallets) ' Wl Test load(rear): 4000 Pa(83.5 Ibs/tt2)' Product Warranty(yrs) 20 25 25 m Series fuse rating: 25A Power Warranty(yrs) 25 25 25 WLIGH-1 EHA 11 Reverse current: 25A Labor Warranty(yrs) 0 25 10 Typical low irradiance performance of module at STC: NE installation manualformountineginstructions. Power inYear1 98% 98% 98% 22 m _ Design load-Test load/1.5lsafety factor) - ---------f----- Annual Degradation 0.25% 0.25% 0.25% .-- _ ----------------- _------i LPower in Year 25 92% 92% 92% - • • See warranty documents for details.Conditions apply r" . w Availablefrom: �Irradiance(W/m') . . N o ,o fV o Founded in 1996,REC G ro up is an international pionee ring solar energy company dedicated to empowering consumers REC Solar PTE.LTD. ^^^ I?• �, , , with clean,affordable solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low 20Tuas SouthAve.14 IJ`1`1` a • carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational Singapore 637312 headquarters in Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific. post@recgroup.com www.recgroup.com Data Sheet Enphase IQ 7X Microinverter Enphase Microinverters Region:AMERICAS INPUT DATA(DC) IQ7X-96-2-US Commonly used module pairings' 320 W-460 W+ Module compatibility 96-cell PV modules Maximum input DC voltage 79.5 V Peak power tracking voltage 53 V-64 V Operating range 25 V-79.5 V Min/Max start voltage 33 V/79.5 V The high-powered smart grid-ready FMax DC short circuit current(module Isc) 10 A Enphase Enphase IQ 7X Micro'M dramatically simplifies the Overvoltage class DC port II DC port backfeed current 0 A Q7X M icroi nverter installation process while achieving the highest PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; system efficiency for systems with 96-cell modules. AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) @ 240 VAC @ 208 VAC Part of the Enphase IQ System,the IQ 7X Micro FPeak output power 320 VA integrates with the Enphase IQ Envoy'", Enphase IQ Maximum continuous output power 315 VA Nominal(L-L)voltage/range2 240 V/211-264 V 208 V/183-229 V Battery'"', and the Enphase Enlighten'"" monitoring Maximum continuous output current 1.31 A(240 VAC) 1.51 A(208 VAC) and analysis software. Nominal frequency 60 Hz Extended frequency range 47-68 Hz The lQ Series Microinverters extend the reliability AC short circuit fault current over 3cycles 5.8Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit' 12(240 VAC) 10(208 VAC) Overvoltage class AC port III undergo over a million hours of power-on testing, AC port backfeed current 18 mA enabling Enphase to provide an industry-leading Power factor setting 1.0 warranty of up to 25 years. Power factor(adjustable) 0.85 leading...0.85 lagging EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.5% 97.0% MECHANICAL DATA Ambient temperature range -400C to+60°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7X-96-2-US) MC4(or Amphenol H4 UTX with optional Q-DCC-5 adapter) Easy to Install Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) • Lightweight and simple Cooling Natural convection-No fans • Faster installation with improved,lighter two-wire cabling Approved for wet locations Yes • Built-in rapid shutdown compliant(NEC 2014&2017) Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Efficient and Reliable Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES • Optimized for high powered 96-cell*modules Communication Power Line Communication(PLC) • Highest CEC efficiency of 97.5% Monitoring Enlighten Manager and MyEnlighten monitoring options • More than a million hours of testing Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break • Class II double-insulated enclosure disconnect required by NEC 690. ENPHASE. 0 UL listed Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 Smart Grid Ready This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC 6�ENJI Ili RN • Complies with advanced grid support,voltage and and DC conductors,when installed according manufacturer's instructions. ,� o �aIon frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U1.No enforced DC/AC ratio.See the compatibility calculator at https7//enphase.com/en-us/support/module-compatibility. *The IQ 7X is required to support 96-cell modules. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. ® EN P H AS E. To learn more about Enphase offerings,visit enphase.com EN P H AS E. To learn more about Enphase offerings,visit enphase.com �./ `/ @ 2019 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2019-3-26 Data Sheet Enphase Networking Enphase IQ Envoy MODEL NUMBERS 71 Enphase IQ Envoy'" Enphase IQ Envoy communications gateway with integrated revenue grade PV ENV-IQ-AM1-240 production metering(ANSI C12.20+/-0.5%)and optional consumption monitoring(+/-2.5%). Includes Enphase IQ Envoy The Enphase IQ EnvoyTM communications gateway one 200A continuous rated production CT(current transformer). delivers solar production and energy consumption ACCESORIES(OrderSeperately) Enphase Mobile Connect'" Plug and play industrial grade cellular modem with data plan for systems up to 60 data to Enphase EnlightenTM monitoring and analysis CELLMODEM-M1 (4G based LTE-M/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin software for comprehensive,remote maintenance and CELLMODEM-MI-B(4G-based LTE-M1/5-year data plan) Islands,where there is adequate cellular service in the installation area.) Consumption Monitoring CT Split-core consumption CTs enable whole home metering. management of the Enphase IQ System. CT-200-SPLIT Ensemble Communications Kit Installed at the IQ Envoy.For communications with Enphase Encharge"storage COMMS-KIT-01 and Enphase Enpower'"smart switch.Includes USB cable for connection to IQ With integrated revenue grade production metering Envoy or Enphase IQ Combiner"and allows wireless communication with Encharge and Enpower. and optional consumption monitoring, Envoy IQ is the POWER REQUIREMENTS platform for total energy management and integrates Power requirements 120/240 VAC split-phase. Max 20 A overcurrent protection required. with the Enphase Ensemble Tmandthe Enphase IQ Typical Power Consumption 5W BatteryTM. CAPACITY Number of microinverters polled Up to 600 MECHANICAL DATA Dimensions(WxHxD) 21.3 x 12.6 x 4.5 cm(8.4"x 5"x 1.8") Smart Weight 17.6 oz(498 g) • Enables web-based monitoring Ambient temperature range -40°to 65'C(-40°to 149'F) ENPHASE and control -40'to 46'C(-40'to 115*F)if installed in an enclosure Bidirectional communications for Environmental rating IP30.For installation indoors or in an NRTL-certified,NEMA type 3R enclosure. � • remote upgrades Altitude To 2000 meters(6,560 feet) •Supports power export limiting and Production CT Limited to 200A of continuous current/250A OCPD-72kW AC zeroexport applications Internal aperture measures 19.36mm to support 250MCM THWN conductors(max) UL2808 certified for revenue grade metering Consumption CT For electrical services to 250A with parallel runs up to 500A Internal aperture measures 0.84"x 0.96"(21.33mm x 24.38mm)to support Simple 3/0 THWN conductor Easy system configuration using UL2808 certified,for use at service entrance for services up to 250Vac • Enphase InstallerToolkit'"mobile app INTERNET CONNECTION OPTIONS • Flexible networking with Wi-Fi, Integrated Wi-Fi 802.11b/g/n Ethernet,or cellular Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Mobile CELLMODEM-M1 (4G)or CELLMODEM-MI-B(4G).Not included.Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Reliable COMPLIANCE • Designed for installation indoors Compliance UL 61010 1 Desi g CAN/CSA C22.2 No.61010-1 or outdoors 47 CFR,Part 15,Class B,ICES 003 • Five-year warranty IEC/EN 61010-1:2010, EN50065-1,EN61000-4-5,EN61 0 0 0-6-1,EN61 0 0 0-6-2 Metering:ANSI C12.20 accuracy class 0.5(PV production only) CERTIFIED To learn more about Enphase offerings,visit enphase.com v E N P H AS E. To learn more about Enphase offerings,visit enphase.com v EN P HAS E. ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Envoy,and other trademarks or service names are the trade- marks of Enphase Energy,Inc.Data subject to change.06-30-2021 Data Sheet Enphase Q Cable Accessories Enphase Q Cable Accessories REGION:Americas CONDUCTOR SPECIFICATIONS Certification UL3003(raw cable),UL 9703(cable assemblies),DG cable Flame test rating FT4 Compliance RoHS,OIL RES I,CE,UV Resistant,combined UL for Canada and United States Conductor type THHN/THWN-2 dry/wet Enphase The Enphase Q CableT' and accessories are part of Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break the latest generation Enphase IQ SystemT".These disconnect required by NEC 690. QCable Accessories accessories provide simplicity, reliability,and faster Q CABLE TYPES/ORDERING OPTIONS Installation times. Connectorized Models Size/Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG/277 VAC 1.3 m(4.2 ft) Portrait 240 Q-12-17-240 12 AWG/277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Q-12-20-200 12 AWG/277 VAC 2.3 m(7.5 ft) Landscape(72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number i Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Enphase Q Cable Field-wireable connector(male) Q-CONN-10M Make connections from any open connector • Two wire,double insulated Enphase Q Cable Field-wireable connector(female) Q-CONN-10F Make connections from any Q Cable open connector is 50%lighter than the previous generation Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Enphase cable 4 • New cable numbering and plug and play Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors,DC connectors,and AC module mount connectors speed up installation and simplify Q Cable sealing caps(female) Q-SEAL-10 One needed to cover each unused connector on the cabling wire management • Link connectors eliminate cable waste Terminator Q-TERM-10 Terminator cap for unused cable ends Enphase EN4 to MC4 adaptor' ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4(TE PV4-S SOLARLOK). 150mm/5.9"to MC4. Enphase EN4 non-terminated adaptor' ECA-EN4-FW For field wiring of UL certified DC connectors.EN4(TE PV4-S SOLARLOK)to non-terminated cable.150mm/5.9" Field-Wireable Connectors Enphase EN4 to MC4 adaptor(long)' ECA-EN4-S22-L Longer adapter cable for EN4(TE PV4-S SOLARLOK)to MC4.Use with split cell modules or PV modules with short DC cable.600mm/23.6" • Easily connect Q cables on the roof without Replacement DC Adaptor(MC4) Q-DCC-2 DC adaptor to MC4(max voltage 100 VDC) complex wiring UTX Adaptor DC Replacement p p ( ) Q-DCC-5 DC adaptor to UTX(max voltage 100 VDC) • Make connections from any open connector and center feed any section of cable within 1.Qualified per UL subject 9703. branch limits • Available in male and female connector types TERMINATOR SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends,sold in packs of ten and cable connections (Q-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL t CABLE CLIP Plan to use at least one per Used to fasten cabling to the racking installation,sold in packs of ten or to secure looped cabling,sold in (Q-DISC-10) �} packs of one hundred(Q-CLIP-100) To learn more about Enphase offerings,visit enphase.com ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ E N P H AS E• Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. E N P H AS E® To learn more about Enphase offerings,visit enphase.com �� 2020-06-26 %.I Snapomrack- UR-40 - . -UR-60 A sleek, straightforward . . . .f types. Ultra Rail Solar Mounting Solutions features two rail profiles; UR-40 is a lightweight rail profile that is suitable for most geographic Rail -g • • - � - • - � • • rail Ultra profilecompatible with all . . . . ease of The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge d � Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management offering .� includes Junction Boxes, Universal Wire �'✓ Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 The Ultimate Value in Rooftop Solar Standard Heavy Duty UR-60 Rail • • • - - • • • • • - • UR-60 rail profile provides increased span capabilities for high wind speeds and snow loads y • • • • • • • • Taller, stronger rail profile includes profile- • - • - specific rail splice and end cap• All existing mounts, module clamps, and accessories are retained for the same great '+ • • • • - install experience RESOURCES snapnrack.com/resources DESIGN snapnrack.com/Configurator WHERE TO BUY snapnrack.com/where-to-buy . . . . SnapNrack- snapnracil Solar Mounting Solutions n10 Idllllll Industry Leading Spans for a Light Rail Solution SnapNrack Umbrella Sealing Technology This table was prepared in ,. compliance with applicable , engineering codes and 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 190 standards. Values are based on o the following: 5 O 10 Featuring New Innovative Flashing • ASCE 7-10 15 • Chapter 30 Wind Loads & 20 O Smaller 9"x12" size allows for easier Chapter 7 Snow Loads 25 Insertion under shingles • Roof Slope: 7 - 27 deg 30 • Roof Height: 0 - 30 ft 35 © Alignment markers make it easy to • Exposure: B . 40 locate pilot holes • Roof Zone: I . 45 • Module Orientation: Portrait 50 © Rounded corners make for easier . Module Type: 60 Cell Modules 60 Insertion & eliminate corner points from • Roof Type: Comp 70 80 folding up 9System 0 Span Key 100 6 ft Spans no • Innovative Flashing Elevates Protection. New flashing uses a fully formed raised cone to 4 ft Spans 120 2 ft Spans prevent any potential water from getting into penetration. Feel secure as the flashing is Visit SnapNrack.com for detailed span tables and certifications. one piece and doesn't rely on multiple parts sealing together. • Mechanical Design Creates a Lifelong Seal. Patented Umbrella technology utilizes unique Single Lag Secures Umbrella Washer to seal lag bolt, L Foot, Mount to Roof and flashing and prevent any potential roof leaks. Technology passes UL 2582 Umbrella Gasket Wind Driven Rain Test without a rubber Raised Cone Flashing seal, however rubber gasket is included Umbrella as er for extra peace of mind. • Single Fastener Eliminates Extra Steps. Utilize one lag bolt with Umbrella Washer to secure the entire mount assembly and Raised Cone Flashing flashing. No longer necessary to attach a base, then a flashing, then a mount as all Pre as ultra Rail are secured in one step. I L Foot &Clamp • Single Tool Installation. SnapNrack Certifications was the first in the industry to develop a complete system that only requires a SnapNrack Ultra Rail system has been evaluated by Underwriters Laboratories (UL) and Listed single tool. That tradition is continued as to UL/ANSI Standard 2703 for Mechanical Loading and Fire. Additionally it is listed to UL 2582 for wind-driven rain. a 1/2" socket is still the only tool necessary to secure the mount as well as all other map CCK S parts of the system. `"l"+ionsl Note:Flashing shown in yellow for illustration purposes only. 877-732-2860 www.snapnrack.com contact@snapnrack.com ©2018 by SnapNrack Solar Mounting Solutions.All rights reserved