Loading...
HomeMy WebLinkAboutFinal egress review 8180 East River Road APPROVED Clarke - 8180 East River Road Jensen D10/17/2023 This plan copy to be at job site SEPARATE PERMITS FOR: ELECT, PLUMB. MECH. Existing Basement Window New Basement Window AL z' 10" 1' 5 1/8" =install 3' 7 1/2" Smoke detectors in each sleeping room and on each level of the house per R314 CO detection per R315 2020 1 RC. 1311 window meets minimum height from bottom of window to finished floor (less than 42") Window Clear Opening = 5.921sft Clear opening width = 22.8125" Clear opening height = 37.375"