Loading...
HomeMy WebLinkAboutDAVID GAMRADT Permit plans 10.25.23 ALL TOTAL ROOF SURFACE AREA E N E R G Y (PLAN VIEW):1,519 SQ FT TOTAL RFACEA EA(PLAMODULE COMPANY INFORMATION SURFACE AREA(PLAN VIEW) 378.36 SQ FT r ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION DAVID GAMRADT 6381 MADISON ST NE FRIDLEY, MN 55432 PO 66150 Panel Type JA 395 # of Panels 24 System Size (kW) 9.48 FLUSH ROOF MOUNT NOTES: 1. (24)ENPHASE IQ 8M INVERTER(S) 2.ARRAY 1: 20'TILT.269°AZIMUTH / / AZIMUTH REVISIONS LAST:03/30/23 AH PROJECT-PAGE TITLE COVER PAGE PAGE NUMBER AO SOUTH ELEVATION ALL ENERGY COMPANY INFORMATION ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION DAVID GAMRADT 6381 MADISON ST NE FRIDLEY, MN 55432 PO 66150 SYSTEM DETAILS 0 NOTES: 60 1. ELEVATIONS MAY VARY DEPENDING ON GROUND ELEVATION BUT ARE DRAWN TO THE BEST OF OUR ABILITY 2. 2x4 TRUSS 16" OC - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WEST ELEVATION SETBACKS: 18" FROM RIDGE 18" FROM BOTH SIDES OF VALLEY 36" FROM EDGE REVISIONS LAST:03/30/23 AH M i O PROJECT-PAGE TITLE ELEVATION DRAWINGS PAGE NUMBER Al ALL ENERGY i SOLAR I COMPANY INFORMATION ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION DAVID GAMRADT 6381 MADISON ST NE FRIDLEY, MN 55432 SNR FLASHING PO 66150 2x4 TRUSS 16" OC SYSTEM DETAILS SNAP-N-RACK 1 1 i MOUNTING HARDWARE: I I I I I I I I I I I I I I 1. (50)L-FEET 2. (8) RAIL SPLICES 1 3. CLAMPS I I (44)MIDCLAMPS I (8)ENDCLAMPS 4. RAIL LENGTHS: (12)172"RAILS 2x4 TRUSS 16"OC I I I I I I I I I I I I I I ' ' ARRAY 1 *STRINGING TO BE DETERMINED ON SITE REVISIONS LAST:03/30/23 AH (24)JA JAM54S31 MODULES (24)ENPHASE IQ 8M INVERTER(S) CIRCUITS: PROJECT-PAGE TITLE (3)CIRCUIT(S)OF 8 MICROS RAIL AND MAX CIRCUIT 15A 20A STRINGING LENGTH (120/240V) BREAKER BREAKER DIAGRAM ENPHASE IQ7 12 16 PAGE NUMBER ENPHASE IQ7+ 9 13 A2 ENPHASE IQ7A 8 11 LABELS LOCATED ON PV PRODUCTION METER, BI- ALL DIRECTIONAL METER, AC DISCONNECT(S), INVERTER(S), AND ENERGY APPROPRIATE LABELS ON MAIN ELECTRIC SERVICE. ALL SOLAR I LABELS ARE PERMANENT,WEATHERPROOF, AND DURABLE 18" COMPANY INFORMATION THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD POWERLINES. ALL ENERGY SOLAR, INC 1264 ENERGY LANE DISTANCES: ST PAUL, MN 55108 SOLAR PANELS - INVERTERS: S MAX (800) 620-3370 INVERTERS- IQ COMBINER PANEL: 75' MAX 175' INFO@ALLENERGYSOLAR.COM IQ COMBINER PANEL-UTILITY AC DISCONNECT: 2' UTILITY AC DISCONNECT-BI-DIRECTIONAL METER: 2' B E N N ETT D R N E CLIENT INFORMATION BI-DIRECTIONAL METER-MAIN ELECTRIC SERVICE: 5' DAVID S GAMRADT CALL-OUTS: 6381 MADISON ST NE FRIDLEY, MN 55432 1: SOLAR PANELS PO 66150 2: INVERTERS 3: IQ COMBINER PANEL 4: UTILITY AC DISCONNECT SYSTEM DETAILS 5: BI-DIRECTIONAL METER NOTES: 6: MAIN ELECTRIC SERVICE 1.(24)ENPHASE IQ 8M INVERTER(S)=7.8kW AC 2.ARRAY 1: 269'AZIMUTH,20'TILT (24)JA 395W=9.48kW 1&2 A W `° M �. 0 Z H U) Z 0 ACCOUNT: 51-0649937-6 SETBACKS PER PREMISE: 303775311 Q I FIRE CODE METER: 13542135 CASE NUMBER: TBD CAZIMUTH C N NOTES: w 1. LOCATION OF SERVICE PANEL AND ELECTRICAL o EQUIPMENT ARE SHOWN. FINAL LOCATION MAY - CHANGE REVISIONS LAST:03/30/23 AH 2. LOCATION OF SERVICE PANEL AND ADDITIONAL ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE 3. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION 4.AC DISCONNECT AND PRODUCTION METER IN PROJECT-PAGE TITLE READILY ACCCESSIBLE LOCATION WITHIN 10' OF MAIN SERVICE METER/BI-DIRECTIONAL METER. 24/7 UNESCORTED KEYLESS ACCESS TO BE PROVIDED FOR UTILITY AC DISCONNECT, PV PRODUCTION SITE MAP METER,&BI-DIRECTIONAL METER. 5. PV EQUIPMENT SHALL BE INSTALLED IN PAGE NUMBER ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES �� PER NEC 705-10, 690-17, &690-64(b)(5). ALL ENERGY (24) JA JA COMPANY INFORMATION 9.48kW 8kW ALL ENERGY SOLAR, INC MODULE DETAILS: 1264 ENERGY LANE SOLAR ST PAUL, MN 55108 (24)JA (800) 620-3370 5' MAX JAM54S31-395/MR/1500V INFO@ALLENERGYSOLAR.COM RATED POWER CLIENT INFORMATION AT STC: 395W VMP: 30.84V DAVID S GAMRADT 6381 MADISON ST NE IMP: 12.81A FRIDLEY, MN 55432 VOC: 36.98V PO 66150 DC (24) EQNPHASE ISC: 13.7A SYSTEM DETAILS INVERTER DETAILS: 120/240V ENPHASE IQ8M-72-2-US SYSTEM SIZE:9.48kW DC C SEE LABEL(S) N/A TO UTILITY MAXIMUM POWER:7.8 kW AC ON FOLLOWING PAGES Rating: 325W OPERATING VOLTAGE:120/240V CEC Weighted Efficiency: 97% MAXIMUM CURRENT:32.4A Max DC Voltage: 58V ACCOUNT:51-0649937-6 Max AC Output Current: 1.35A PREMISE:303775311 Nominal Voltage Range: METER: 13542135 50' MAX 3/4" EMT: 240V/ 211-264V (1-Phase) ` ,� ^ CASE NUMBER:TBD (6) #10 THWN Nominal Frequency: 60 Hz XCEL ENERGY (1) #10 GROUND BI-DIRECTIONAL METER 120/240V, 1-PHASE, 3-WIRE NOTES: SEE LABEL(S)41,42 ON FOLLOWING PAGES 1.DESIGN MEETS NEC CODE AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND WITH 2' MAX 1" PVC: 5' WARNINGS, SIGNAGE,IGNAGE,AND APPLICABLE (2) #6 THWN EXISTING PLAQUES PER NEC705-10, 690- (1) #6 NEUTRAL CONDUIT 17, &690-64(b) (5) ENPHASE IQ COMBINER PANEL 2. SOLAR MODULES,INVERTERS, 120/24OV: 125A: 1 PHASE AND CORRESPONDING PLACARD INDICATING ELECTRICAL EQUIPMENT ARE "NO LOAD TO BE SERVED" FT50A LISTED. SEE LABEL(S)16, 18,24 3.INVERTERS ARE UL 1741 ON FOLLOWING PAGES 5' LISTED EXISTING 4.PV INTERCONNECTION IS A POINT OF COMMON COUPLING CONDUIT SECONDARY INTERCONNECTION LINETAP INSIDE MAIN SERVICE REVISIONS DISCONNECT VIA POLARIS LUGS. LAST:03/30/23 AH 2' MAX 3/4" EMT: INSTALLATION IS A SECONDARY MAIN (2) #10 THWN INTERCONNECTION. MAIN (1) #10 NEUTRAL UTILITY FUSED (1) #10 GROUND AC DISCONNECT VISIBLE-OPEN TYPE,LOCKABLE, READILYACCESSIBLE PROJECT-PAGE TITLE RPA /PAC ELECTRICAL 100A RATED BUS LINE DIAGRAM 1 PHASE,60A, 120/240V MAIN SERVICE PANEL PAGE NUMBER SEE LABEL(S)10, 14, 15, 16,20,35 SEE LABEL(S)14, 16 ON FOLLOWING PAGES ON FOLLOWING PAGES A4 *DISTANCES NOT TO SCALE WARNING : PHOTOVLTAICNOTE: LABELS ARE FOR ALL • • • 6 GENERAL REFERENCE. ENERGY NOT ALL LABELS ARE USED POWER SOURCE , , FOR EVERY INSTALLATION. COMPANY INFORMATION 5: EXPOSED DC CONDUIT, JUNCTION BOXES, ECT ALL ENERGY SOLAR, INC 1264 ENERGY LANE • 7 ST PAUL, MN 55108 10 (800) 620-3370 RAPID SHUTDOWN INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION FOR SOLAR PV SYSTEM DAVID S GAMRADT 6381 MADISON ST NE WARNICFRIDLEY, MN 55432 P ' 13 F A 8: PO 66150 L Aj,,C DISCONNEq- -" TRICAL SHOCK HAZARD SYSTEM DETAILS r NOT TOUCH TERMINALS INALS ON BOTH LINE AND A WARNING DUAL POWER SOURCE 14 SIDES MAY BE ENERGIZEDN THE OPEN POSITION SECOND SOURCE IS PHOTOVOLTAIC SYSTEM 15 PHOTOVOLTAIC AC DISC OPERATINGMAII 4�, #,lFOVOLTAIC MAXIMUM AC • OPERATING AC VOLTAGE: SYSI"rir-DISCONNECT INTERCONNECTION17 20 LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY DISCONNECT MOUNTED,AND COMPLY WITH SWITCH - NEC 690 SOLAR PV SYSTEM EQUIPPED 35 ACCOUNT:51-0649937-6 PRODUCTION WITH RAPID SHUTDOWN PREMISE:303775311 AWARNING 36 METER: 13542135 POWER SOURCE OUTPUT CONNECTION. DO NOT 21 CASE NUMBER:TBD RELOCATE THIS OVERCURRENT DEVICE. REVISIONS TURN RAPID SHUTDOWN HOUSE LAST:03130/23 AH SWITCH TO THE CAUTION 37 METER "OFF" POSITION TO SOLARELECTRIC PVPANELS PV SYSTEM CIRCUIT BREAKER IS BACKFED SHUT DOWN PV SYSTEM 41 PROJECT-PAGE TITLE AND REDUCE CAUTION : SOLAR ELECTRIC LABELS SHOCK HAZARD IN THE ARRAY SYSTEM CONNECTED PAGE NUMBER 42 A5 ALL 15 ENERGY i SOLAR I EMERGENCY DISCONNECT CAUTION . COMPANY INFORMATION ALL ENERGY SOLAR, INC DISCONNECTSERVICE 1264 ENERGY LANE MULTIPLE SOURCES OF POWER (800) 620-3370- STPAUL, 8 -3370 INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION PV COMBINER PANEL DAVID S GAMRADT 6381 MADISON ST NE FRIDLEY, MN 55432 INTERCONNECTION 17 UTILITY PV DISCONNECT PO 66150 DISCONNECT PV SERVICE DISCONNECT SYSTEM DETAILS HOUSE SERVICE DISCONNECT VOLTAGEMAXIMUM 22 SOLAR ARRAYMAXIMUM CIRCUIT CURRENT N MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER • - •-DC CONVERTER All Energy Solar www.allenergysolar.com (800) 620-3370 18 . 24 LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED,AND COMPLY WITH NEC 690 PVCOMBINER ACCOUNT:51-0649937-6 POWER • PREMISE:303775311 PANELONLYMETER: 13542135 NO LOADSPHOTOVOLTAICCASE NUMBER:TBD REVISIONS Operating Voltage : 120/240 LAST:03/30/23 AH MaximumMaximum Current : 32 . 4 Amps KWPower : • •• PROJECT-PAGE TITLE LABELS 2 PAGE NUMBER 43 A6