Loading...
HomeMy WebLinkAboutStamped Permit Set SHEET INDEX SCOPE OF WORK OCCUPANCY AND CONSTRUCTION TYPE STREET VIEW AERIAL VIEW ' PV-1 : TITLE PAGE OCCUPANCY- R3 solaus ........:.................................... ................. .. .... ............... PV-2 : SITE PLAN PAGE CONSTRUCTION TYPE-V osunwor company ........:.................................... PV-3 : STRUCTURAL PAGE INSTALLATION OF ROOF MOUNTED PV SYSTEM INCLUDES p -,'� REGIONAL OFFICE ................................... .. (10)ZXM7-SH108-410/M PV MODULES CONNECTED TO SOLCIUS, LLC PV-4 : ELECTRICAL DIAGRAM PAGE r ............................... (5) NEP BDM-300X2 INVERTER « ' 9124 GRAND AVE S PV-5 EQUIPMENT LABELS PAGE (2) MODULES PER INVERTER - A " f SUITE 105 PV-8 : RACK AND RAIL DIAGRAM (N) DC SYSTEM SIZE:4.1 KW-DC Latitude Longitude � ;� MINNEAPOLIS, MN (N)AC SYSTEM SIZE: 2.5 KW-AC a _= :.................................... 45.076266 -93.262201 5420 EQUIPMENT SPECIFICATIONS "" r (844)357 2258 RACKING: ........:.................................... SNAPNRACK UR-40 RAILS W/SPEEDSEAL(W/LAGS) " . �q, CUSTOMER ATTACHMENTS - �^ ............................... SCOTT LEIFERMANN 5960 4TH ST NE FRIDLEY, MN, 55432 APPLICABLE CODES CONSTRUCTION NOTES 2017 NATIONAL ELECTRIC CODE (NEC) ALL GROUNDING ELECTRODES AS DESCRIBED IN NEC 250.52(A)(1)-(A)(7)THAT ARE PRESENT AT EACH BUILDING OR STRUCTURE SERVED UTILITY ............................... 2020 MINNESOTA BUILDING CODE SHALL BE BONDED TOGETHER TO FORM THE GROUNDING ELECTRODE SYSTEM.WHERE NONE OF THESE GROUNDING ELECTRODES EXIST, XCEL ENERGY- 2020 MINNESOTA RESIDENTIAL CODE A. ONE OR MORE OF THE GROUNDING ELECTRODES SPECIFIED IN NEC 250.52(A)(4)-(A)(8)SHALL BE INSTALLED PER NEC 250.50.ADDITIONAL MINNESOTA 2020 MINNESOTA FIRE CODE GROUNDING ELECTRODES SHALL BE INSTALLED PER NEC 250.53.THE GROUNDING OR BONDING CONDUCTOR SHALL BE CONNECTED TO THE GROUNDING ELECTRODE BY LISTED CLAMPS PER NEC 250.70. ............................................................................................................................................................................... SOLCIUS PROJECT# ROOFTOP MOUNTED PHOTOVOLTAIC SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION ................ B' INSTRUCTIONS. ROOF PENETRATIONS SHALL BE FLASHED AND SEALED IN ACCORDANCE WITH IRC R909.3 P-277370-23 ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE FINANCER C. OPERATION AND MAINTENANCE OF SUCH EQUIPMENT PER NEC 110.26. ............................................................................................................................................................................... DIVIDEND D. ALL PLAQUES AND SIGNS WILL BE INSTALLED AS REQUIRED BY NEC. JURISDICTION ............................................................................................................................................................................... ............................... E. CONDUIT WILL BE INSTALLED IN COMPLIANCE WITH NEC 358. ......................................................................................................................................................................... FRIDLEY F. ROOF COVERINGS SHALL COMPLY WITH IBC 1506.2, 1507 & IRC R904.3. ............................................................................................................................................................................... CIRCUIT BREAKERS, IF BACKFED,SHALL BE SUITABLE FOR SUCH OPERATION PER NEC 705.12(D)(4)AND WILL BE INSTALLED PER NEC DESIGNER G. 408.36(D). H. INVERTERS UL LISTED 1741 PER IRC R324.3. SYSTEM SIZE ............................................................................................................................................................................... ............................... ROOFTOP MOUNTED PHOTOVOLTAIC PANEL SYSTEM SHALL BE TESTED, LISTED AND IDENTIFIED WITH A FIRE CLASSIFICATION IN (N) DC SIZE:4.1KW I' ACCORDANCE WITH UL 1703. (N)AC SIZE:2.5KW NON-CURRENT-CARRYING METAL PARTS OF EQUIPMENT, RACEWAYS,AND OTHER ENCLOSURES, IF GROUNDED,SHALL BE CONNECTED TO J. AN EQUIPMENT GROUNDING CONDUCTOR BY ONE OF THE METHODS SPECIFIED IN NEC 250.134(A) OR (B). VERSION ............................................................................................................................................................................... 1.4.3 THE DISCONNECTING MEANS FOR UNGROUNDED CONDUCTORS SHALL CONSIST OF A MANUALLY OPERABLE SWITCHES OR CIRCUIT K. BREAKERS COMPLYING WITH NEC 690.15(D)(1). ............................................................................................................................................................................... I hereby certify that this L. THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE PERFORMED ONLY BY QUALIFIED DATE PERSONS PER NEC 690.4(C). plan,specification,or 11/1/2023 ...................................................................................................................................................................... as prepared by me or under was IS THE DUTY OF THE PERSON REQUESTING ANY INSPECTIONS REQUIRED BY THE IRC TO PROVIDE ACCESS TO AND MEANS FOR or under my direct M. INSPECTION OF SUCH WORK PER IRC R109.3. SCALE supervision and that I am a NOT TO SCALE duly Licensed Engineer and t e I s f the state of M s SHEET TITLE TITLE PAGE Signature: License Number: 57699-6 Digitally sealed by SHEET# ............................... Arlo Hu is Date: �1/� j aon PV-1 AZIMUTH AND TILT TABLE EQUIPM ENT LABELS ". r':;.':: N MODULE SOLAR Q ROOF ACCESS FIRE SETBACKS ROOF: AZIMUTH ROOF TILT ROOF TYPE 320 03 OI COUNT : ACCESS ...........:.............:....................................................... O2 JUNCTION BOX ::..:.:.. :r..... 31 0ao50 �' 40350 0 20 30 A 88 21......... 4 ASPHALT SHINGLE 1830 sq ft 0 a sun company TOTAL ROOF AREA:: O3 PV MODULES .................. 9 0 B 268 21 3 ASPHALT SHINGLE """""""""""""""""""""' PROPOSED SOLAR AREA:: 210.44 sg ft 8 so .................................................................................. ® CONDUIT RUN ........................................... W27 AZIMUTH o C 358 : ....21......:.....3.....:.......ASPHALT SHINGLE 26 E PROPOSED SOLAR WEIGHT:: 610.26 Ib REGIONAL OFFICE ...............:........... ......... .. ........._ ..... .... ..... 00 ............................. 5 BILLING METER PROPOSED%COVERAGE:' 11.5% 2s ................................................................... ........... ©..MAIN SERVICE PANEL................... 2423 20 SOLCIUS, LLC 0 40 0 9124 GRAND AVE S O7 COMBINER PANEL 210200,901 01101601 0 SUITE 105 :...........:.............:............:...............................:........... ...........................................® FUSED AC DISCONNECT MINNEAPOLIS, MN s ......................................................................:........... ........................................... 55420 .....:............:.............:............:...............................:........... ........................................... (844)357-2258 ........................................................................................ ZNSHINE ZXM7-SH108-410/M TOTAL:10 ........................................... ..................................................................................... NEP BDM-300X2 TOTAL:S NOTES: SCOTT LEIFERMANN 5960 4TH ST NE APPLICATION#: FRIDLEY, MN, 55432 1. 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL XCEL ENERGY UTILITY EQUIPMENT _ 2. THE AC DISCONNECT IS 60th Ave NE CROSS STREET MINNESOTA NOTE:WITHIN 10 FEET APPROXIMATELY 300FT NOTF:OF THE MAIN BILLING METER SOLCIUS PROJECT# 3. THERE ARE NO CLEARANCE 1�_6„ 26'-9" 13'-4" P-277370-23 ISSUE. TYP 1 ROOF C Z FINANCER ............................... MAIN SERVICE METER: 1-PHASE, DIVIDEND 240V •'.t•�� ;.... JURISDICTION KW AC NAMEPLATE RATING OF 12 -10 uJ INVERTERS: 500W 3 ; :!•; z m }, FRIDLEY Ln 1-PHASE INVERTER SYSTEM y' a 1-PHASE DER SYSTEM 29 O "..-. ::f ,'. °0'27'-11" +�.+ DESIGNER ONLY ONE DER SYSTEM SHALL BE Q INSTALLED �r. THERE IS NO EXISTING DER ':,':`' '. Q1 SYSTEM SIZE SYSTEM (N) DC SIZE:4.1KW SERVICE METER IS OVERHEAD, NO O p O ``' " ` (N)AC SIZE:2.5KW CLEARANCE CONCERN SERVICE ENTRANCE/ VERSION UTILITY METER 4 1.4.3 REFERENCE POINT 5 OF APPLICABILITY 6 DATE hereby certify that this 7 plan,specification,or 11/1/2023 report was prepared by me UTILITY AC DISCONNECT-VISIBLE-OPEN 8 or under my direct TYPE, LOCKABLE,AND READILY Ir 1 3'-6" SCALE supervision and that I am a ACCESSIBLE duly Licens Tonal 1" — 10.666666' Engineer a s of UTILITY AC DISCONNECT WILL BE the state a INSTALLED WITHIN 10' OF THE MSP. INTERCONNECTION SHALL BE SECONDARY SHEET TITLE SITE PLAN Signature: License Number: 57699-6 Digitally sealed by SHEET# ............................... Arid Hulic Date: PV-2 ............................... ROOF LABEL ROOF TYPE MOUNTING TYPE AREA OF ARRAY(SQ FT) GROSS WEIGHT(IBS) DEAD LOAD RATING(ILBS/SQ FT) EXISTING STRUCTURAL FRAMING MAX RAIL SPAN SOICIUS A ASPHALT SHINGLE SPEEDSEAL(W/LAGS) 84.17 180.7599945 2.15 2X8 @16"O.C. 4' a sunworks company ...................................:...........................................................:............................................................................................................:.................................................................................................................................................................................................................................... B ASPHALT SH IN GLE SPEEDSEAL(W/LAGS) 63.13 135.5699959 2.15 2X8 @16"O.C. 4' REGIONAL OFFICE .......................................................................................................................................................:......................................................:................................................:....................................................................:....................................................................:........................................ C ASPHALTSHINGLE SPEEDSEAL(W/LAGS) 63.13 135.5699959 2.15 2X8 @16"O.C. 4' SOLCIUS, LLC ...................................:............................................................:......................................................:......................................................:.........................................................................................................................................................................................:......................................... 9124 GRAND AVE S SUITE 105 ............................................................................................................................................................................................................:.....................................................................................................................:.............................................................................................................. MINNEAPOLIS, MN 55420 ....................................................................................................................................................... ...................................................................;...................................................................:........................................ (844)357-2258 CUSTOMER ...................................;........................................................... ...................................................... ..................................................... ......................................................................................................................:................................................................... ........................................ SCOTT LEIFERMANN 5960 4TH ST NE ATTACHMENT POINT FRIDLEY, MN, 55432 UTILITY 2'TYP. ............................... 2, t'TVP �. XCEL ENERGY- '� ROOF C MINNESOTA *RACKING DIAGRAM ABOVE IS FOR LABELING PURPOSES ONLY. ACTUAL REPRESENTATION OF EQUIPMENTAND CONNECTIONS SHOWN BELOW SOLCIUS PROJECT# P-277370-23 FINANCER DIVIDEND JURISDICTION FRIDLEY DESIGNER m LL Q SYSTEM SIZE LL O O O (N) DC SIZE:4.1KW O (N)AC SIZE:2.5KW VERSION ............................... 1.4.3 I hereby certify that this DATE plan.specification.or 11../1/20. .. 23 report was prepared by me or under my direct SCALE supervision and that I am a duly Licen Lji,,onal NOT TO SCALE Engineer nd af the state f n SHEET TITLE .....ATTACHMENT.. Signature: SPACING License Number: 57699-6 Digitally sealed by SHEET# ............................... Arlo Hulic D 11� D� PV-3 Date- ............................... CONDUIT AND CONDUCTOR SCHEDULE EQUIPMENT SCHEDULE ......................................................................................................-................................................................................................................................. MIN.CONDUCTOR MIN.CONDUIT .............................................................................................................. TAG:: CONDUCTORTYPE : SIZE(AWG) #OF CONDUCTORS : CONDUITTYPE SIZE TAG DESCRIPTION MANUFACTURER PART NUMBER NOTES SO I S ... ................. ................. ................... .............. .......... PV WIRE 1� Z Q SOLAR ZNSHINE 7XM7-SH108-410/M TOTAL(N)PANEL COUNT:10 a sunworks company A ........... ............... .................;............... ................' IN FREE AIR N/A :........................:........................................................ ...........................................:............................................................ BARE COPPER 6 1 Q MICRO INVERTER NEP BDM-30OX2 (N)INVERTER COUNT:5 THWN-2 10 2 ........>........................................................>.................................................... REGIONAL OFFICE B i •••••••••••••••••............................................................................... MCTHROUGH ATTIC WHERE POSSIBLE,OTHERWISE EMT RUN ON ROOF 3/4 3 JUNCTION BOX THWN-2/EGC/GEC 10 PVC JUNCTION BOX(OR EQUAL) 5133710U CANTER 1 ............................. ....:................................................ THWN-2 10 2 EAT ON R EQUAL DG221NR6 240V 30A 2P 3R VISIBLE LOCKABLE FUSE SIZES 20A C ........................ EMT 3/4„ OO ..........FUSED AC DISCONNECT........... ......................O....QU................. ............. .............................. ......................................................... 9124 GRAND AVE S THWN-2/EGC/GEC 10 1 ' © COMBINER PANEL 125A,240V,8 SPACE/16 CIRCUIT,3R SUITE 105 ............................................................... :.................................................... ....................................................... ......................................................... ................................:...................................>................................ (E)MAIN SERVICE PANEL (E)BUS:225(E)MAIN:200 MINNEAPO LIS, MN .. ...... 55420 1© BILLING METER (844) 357-2258 .....................................................................................................: ........:........................................................:......................................................)........................................................... .......................................................... CUSTOMER ........................................................:......................................................:...........................................................;............................................................ ............................... ........................................................>................................................................................................................. .......................................................... S COTT LEIFERMANN ................................>...................................>................................ ...................................................................................................................... ........................................................... ............................................................ 5960 4TH ST NE FRIDLEY, MN, 55432 MODULE SPECIFICATIONS INVERTER SPECIFICATIONS EXISTING MAIN SERVICE PANEL INFORMATION STC CALCULATION BOX ....•.•.•........................._ZNSHINE ZXM7-SH108-410/M ....................'........'.'.'......'.'.'.....'BDM-300X2....................'.'......'.'.'........'.'.'.... VOLTAGE: i 120/240 ': IV] NEW INVERTER P BDM 30OX2 X 50OW-2.5 KW AC ........................................................................ S:(5)NE ZNSHINE NEP ..................PHASES:.................. ....................1................... e....... ...... P HI 7-H '4 - K....................................................................................._.................._................ ....................................................................................._.................._................ .......................................................b...............................................d................ NEW PANELS:( )Z 5 NEZXM 5 108-410/M 10W-4.1 KW-DC s: 10 N UTILITY MAX POWER-POINTCURRENT(IMP) 13.1 i [A] MAX DC INPUT 60 IV] BOX/BUS RATING: 225 [A] .....................................................................................-..................�................ ........................ ........................ ....................................................................................................... ............................... MAX POWER-POI NT VOLTAGE(VMP) i 31.3 i M MAXOUTPUT 580 [WI MAIN BREAKER: 200 [A] ...........................e..................e. .....................................................................................b..................a................ OPEN CIRCUITVOLTAGE(VOC) 37.5 [VI NOMINALACOUTPUT 240 [VI NEW PV SYSTEM BACKFEED: ' 20 a [A] XCEL ENERGY- .....................................................................................:...................p................ .....................................................................................q..................:................ ............ ............. _..............................................._ ......... SHORT CIRCUIT CURRENT(ISC) 13.84 [A] MAX OUTPUT CURRENT 2.09 i [A] FEED TYPE: BOTTOM FED PV SHALL BE INSTALLED ON LOAD SIDE OF MINNESOTA .....................................................................................}..................i................ ......................................................................................;.................................. .................................................. ......................................... ............ ...e... ...e.... ... MAX POWER(PMAX) I 410 [ [W] ovERcuRRENr PRorEcrloN zo [A] I............... MAIN BREAKER ON THE FEEDER IN ESTIMATED ANNUAL PRODUCTION 4242.22 KWH ..........................izzsABusi.I..2.ioA•Mai'eus"RAT•in;G"""'""""""""" ACCORDANCE WITH NEC 705.12(B)(2)(1)(b) SOLCIUS PROJECT# .......................................................................................................................... PV BACKFE E0(20A)+MAIN BREAKER(200A)_(220-220) ..................................................................(B............................... ..................... P-277370-23 CALCS:NEC 705.12(B)(2)(3)(d) FINANCER DIVIDEND JURISDICTION ............................... FRIDLEY DESIGNER SERVICE CONDUCTORS EXTENDING TO SYSTEM SIZE 4 UTILITY ....................... TO NEPBDG-256 END FED MAIN PANEL (N) DC SIZE: 4.1KW MONITORING TO EXISTING SUBPANEL (E)225A BUS/(E)200A MAIN (N)AC SIZE: 2.5KW (E)225A BUS/ (E)200A MAIN (N)15A-2P 5 VERSION (E)200A-2P ............................... 10 MODULES INA CIRCUIT """"""""1.4.3"""""""' 12 DATE 2oA ...........�.� ............ FUs� 11 1 2023 N r N SCALE (N)20A-2P � ............................... NOT TO SCALE 1 Qj C — SHEET TITLE A 3 B C 11 ELECTRICAL LINE DIAGRAM SHEET# ............................... SOLAR EQUIPMENT ON THE ROOF SPPROT SOLAR EQUIPMENT 5' FROM THE MSP �' PV-4 MAIN SERVICE PANEL SUBPANEL asun company IF USED COMBINER ® AC PANEL REGIONAL OFFICE DISCONNECT (IF USED) INVERTER SOLCIUS, LLC ® 9124 GRAND AVE S ® L8 10' SUITE 105 ® MINNEAPOLIS, MN N, 55420 (844) 357-2258 CUSTOMER NOTES: *DIAGRAM ABOVE IS FOR LABELING PURPOSES ONLY. ACTUAL REPRESENTATION OF EQUIPMENT SCOTT LEIFERMANN PV SYSTEM CONNNECTED PLACARD WILL BE AND CONNECTIONS TO BE INSTALLED SHOWN ON PV-4 5960 4TH ST NE PLACED AT BILLING METER. PV SYSTEM CONNECTED PLACARD WILL BE SOLAR PV SYSTEM EQUIPPED L1 0 WARNING L5 FRIDLEY, MN, 55432 YELLOW WITH BLACK LETTERS WITH RAPID SHUTDOWN NEC 690.56(C)(1)(A) NEC 690.13(B), NEC 705.22 NOTES: UTILITY ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND BE TURN RAPID SHUTDOWN ELECTRICAL SHOCK HAZARD ........... ........ ABLE TO WITHSTAND THE ENVIROMENT THEY ARE INSTALLED, SIGNAGE ALSO CANNOT BE HAND WRITTEN. SWITCH TO THE XCEL ENERGY- CEC110.21(B). "OFF"POSITION TO SOLAR ELECTRIC MINNESOTA SHUT DOWN PVSYSTEM PVPANELS THE DC CONDUCTORS OF AND REDUCE THIS PHOTOVOLTAIC SYSTEM SOLCIUS PROJECT# SHOCK HAZARD ............................... IN THE ARRAY ARE UNGROUNDED AND P-277370-23 MAY BE ENERGIZED FINANCER L2 DIVIDEND ! WARNING JURISDICTION NEC 705.12(B)(2)(3)(b) POWER SOURCE OUTPUT CONNECTION. FRIDLEY DO NOT RELOCATE THIS DESIGNER OVER CURRENT DEVICE. PLACARD WILL BE SYSTEM SIZE ............................... YELLOW WITH BLACK (N) DC SIZE:4.1KW LETTERING (N) AC SIZE: 2.5KW PHOTOVOLTAIC AC DI • L3 • , , • L7 VERSION RATED AC OUTPUT CURRENT:L16 NEC 690.54, NEC 690.13 (B) SWITCH • NEC 690.56(C)(3) 1.4.3 PV AC DISCONNECT SOLAR NOMINALOPERATING AC V• 240 DATE 11/1/2023......... L17 PHOTOVOLTAIC L4PHOTOVOLTAIC SCALE . . . .... . ... ..� SYSTEM CONNECTED I ' • • • L8 .......NOT. . . . TO SCALE. .WARNING ..... NEC 705.12(B)(3) � • � NEC 690.31(G)(3&4)SOURCE SHEET TITLE DUAL POWER SOURCE EQufPMtNT...... *LOCATION: EVERY 10'ALONG ANY CONDUITS OR MC CABLE SECOND SOURCE IS THAT CONTAIN DC CIRCUITS,AT EVERY ENCLOSURE AND AT LABELS EACH SIDE OF WHERE THE CONDUIT OR CABLE PASSES PHOTOVOLTAIC SYSTEM THROUGH A WALL,FLOOR,OR ANY OTHER PARTITION SHEET# NOTE:DC CONDUIT MUST BE A REFLECTIVE SITCKER PV-5 PROJECT SPECS SOlC us RAFTER SIZE: : 2X8 ..............................:.............................. a sunworks company RAFTER SPACING: : 16 ...............................:.............................. REGIONAL OFFICE ROOF TYPE: : ASPHALT SHINGLE MODULE HEIGHT OFF ROOF,RANGE: SOLCIUS, LLC UR-`b:33, _q3, COMP SHINGLE ROOFING,TYP. SNAPNRACK,UR SPEEDSEAL FOOT 9124 GRAND AVE S UR-60:4°-s ATTACHMENT SPACING: MAX 4' SUITE 105 ROOF DECKING,TYP. ............................................................ RAILS/RACKING: : SNAPNRACK UR-40 MINNEAPOLIS, MN SNAPNRACK,5/6--LQ s.s. ............................................................. 55420 LAG SCREW,TYP. 844 357-2258 STRUCUTRAL MEMBER, MOUNTING: : SPEEDSEAL(W/LAGS) ( ) WOOD RAFTER,TYP. CUSTOMER ............................... SCOTT LEIFERMANN 5960 4TH ST NE FRIDLEY, MN, 55432 UTILITY ............................... 1N/r MIN.EMBEDMENT INTO WOOD MEMBER XCEL ENERGY- MINNESOTA 5/I6^ WASHER,S.S. (MAY INCLUDE NEOPRENE SOLCIUS PROJECT# TYPE GASKET) ............................... PENETRATION DETAIL P-277370-23 FINANCER ............................... SNAPNRACK,ULTRA COIL SPRING FOR/6^ ®BOLT4 , S.S. CAVITY IN URSPEEDSEAL FOOT DIVIDEND RAIL MOUNT,THRU OPTIONAL IS FILLED WITH SEALANT TO = ENCAPSULATE AND PROTECT THE ROOF PENETRATION JURISDICTION 5�6^�18 X 2' BOLT, FROM MOISTURE O SERRATED FLANGE,S.S. SNAPNRACK,SPEEDSEAL FRIDLEY FOOT,BASE,SEALING EXPLODED DESIGNER SEALANT SYSTEM SIZE 15�• ROOF DECKING (N) DC SIZE: 4.1KW UR-40 RAIL I UR-60 RAIL STRUCTURAL MEMBER(RAFTER) (N)AC SIZE: 2.5KW VERSION ............................... 1.4.3 I hereby certify that this ............DATE ................... plan,specification,or 11/1/2023 report was prepared by me or under my direct SCALE supervision Qat dulyLicenseNOT TO SCALE Engineerun the state of SHEET TITLE RACK AND RAIL Signature: DIAGRAM- License Number: 57699-6 Digitally sealed by SHEET# ............................... Arlo Hu is Date: �1/� j a� PV-8 ............................... ZXM7-SH108 Series Znshinesolar 10BB HALF-CELL Black ZNSHINESOLAR ZNSHI N ESOLAR Monocrystalline PERC PV Module DIMENSIONS OF PV MODULE(mm) ZXM7 - SH108 Series I-V CURVES OF PV MODULE(400W) 1fi Cells temp.=26°C Beroode 1 30±1 mdtlent I-d.=1000 W/m• 12 Indtlent Inad.=110 w/m° IIII 11 t� Q 10 10BB HALF-CELL Black Monocrystalline PERC PV Module Ominage hales 16-ax3 A C Indtlent lnatl.=fi00 W/m' Barotle + 12:1 N fi tabd V 6 Incident Inatl.=400 W/m' Mwnling h01ee 4-14X9 4 Indtlent I-d.=200 W/m' z p0 5 10 15 ZO 25 30 36 4p +I Voltage[A Jundon bm 12:I 390-410W 21 .00% 0.55% 0R8 2 P-V CURVES OF PV MODULE(400W) soo POWER RANGE MAXIMUM EFFICIENCY YEARLY DEGRADATION Cells emp.=25"C A r ]A -incident Irmd.=1000 W/m- -In I nt Irred.=900 W/m' aoo -Incident Irred.=600 W/m' iaz -Incident Irmd.=40o W/m' G-ding -Indtlent Ired.=200 W/m' G-ding hoke itlenMio3tim 4-04 30a 2 12 YEARS PRODUCT WARRANTY 2j 25 YEARS OUTPUT GUARANTEE 1134±2 m 30 zoo a Front View Back View 'gg f a // `� a rc• �1� I� l PV CYCLE *Remark:customized frame color and cable length available upon request o s to 16 zo 25 3o 3s 40 Znshine Standard C US \ E V Voltage[V] m 100% Common Standard 3 98% o a IEC 61215/IEC 61730/IEC 61701/IEC 62716/UL6 1730 v c90% 15014001:Environmental Management System m ELECTRICAL CHARACTERISTICS I STC* MECHANICAL DATA ISO 9001:Quality Management System J 84.a% 0 80% 15045001:Occupational Health and Safety Management System Nominal Power Watt Pmax(W)* 390 395 400 405 410 Solar Cells Mono PERC 1 5 12 15 �5 ears *Astherearedifferentcertificationrequirementsindifferentmarkets.pleasecontactyourlocalznshinesalesrepresentativeforthespecificcertificates Maximum Power Voltage V 30.50 30.70 30.90 31.10 31.30 Cells orientation 108 (6x18 *Please ch teasedvalid version of Limited Product Warranty which is applicable to the products in the region in which the products are to be used. 9 p( ) ) officially released by ZNSHINE PV-TECH Co.,L[d. Maximum Power Current Imp(A) 12.79 12.87 12.95 13.03 13.10 Module dimension 1722x1134x30 mm(With Frame) Open Circuit Voltage Voc(V) 36.70 36.90 37.10 37.30 37.50 Weight 20.5±1.0 kg KEY FEATURES Short Circuit Current I5C(A) 13.56 13.63 13.70 13.77 13.84 Glass 3.2mm,High Transmission,AR Coated Tempered Glass Excellent Cells Efficient Better Weak Illumination Response Module Efficiency(%) 19.97 20.23 20.48 20.74 21.00 junction box IP68, 3diodes IIIIIIIIII y p 1 OBB ® The data above is for reference only and the actual data is in accordance with the praticaltesting MBB technology reduce the distance between busbars and More power output in weak light condition,such as haze, *STC(Standard Test Condition):Irradiance 1000W/m',Module Temperature 25±2°C,AM1.5 Cables 4 mm',350 mm(With Connectors) *Measuring uncertainity:±3%,all the electrical characteristics such as Power,Im,Vm and FF are within±3%tolerance. finger grid line which is benefit to power increase. cloudy,and early morning. Connectors* MC4-compatible *Please refer to regional datasheet for specified connector ELECTRICAL CHARACTERISTICS I NMOT TEMPERATURE RATINGS* WORKING CONDITIONS Anti PID Adapt To Harsh Outdoor Environment Maximum Power Pmax(Wp) 291.50 295.20 299.00 302.70 306.30 NMOT 44°C12°C Maximum system voltage 1500 V DC Ensured PID resistance through the quality control of cell Resistant to harsh environments such as salt,ammonia, manufacturing process and raw materials. sand, high temperature and high humidity environment. Maximum Power voltage Vmpp(V) 28.30 2B.50 2B.70 2B.90 29.10 Temperature coefficient of Pmax -0.35%/°C Operating temperature -40°C-+85°C Maximum Power Current Impp(A) 10.29 10.35 10.41 10.47 10.53 Temperature coefficient of Voc -0.29%/°C Maximum series fuse 25 A r TIER 1 Excellent QualityMana erment System II II II II v g y Open Circuit Voltage Voc(V) 34.30 34.50 34.70 34.80 35.00 Temperature coefficient of Isc 0.05%/°C Front Side Maximum Static Loading Up to 5400 Pa Global,Tier 1 bankable brand,with independently certified Warranted reliability and stringent quality assurances well Rear Side Maximum Static Loading Up to 2400 Pa advanced automated manufacturing. beyond certified requirements. Short Circuit Current Isc(A) 10.95 11.01 11.06 11.12 11.18 not ro""e"tF°sei"Combiner Boxwim two°`mom strings i"pa`aue`ro""e`a°" *NMOT:Irradiance 800W/m',Ambient Temperature 206C,AM 1.5,Wind Speed 1m/s "RemarcElecticaldata in this catalog do not refer to a single module and they are not partofthe offer. They onlyserveforcompadson among different module types. * *Caution:Please be kindlyadvisedthat Pvmodules should be handled and installed byqualified peoplewho have professional skills Improved Aesthetics C PACKAGING CONFIGURATION and please carefully read thesafety and installation inshuc ons before using our PV modules. Piece/Box 36 Compared to conventional modules,this full black modules have a more uniform appearance and superior aesthetics. Piece/Container(40'HQ) 936 *Customized packaging is available upon request Founded in 1988,ZNShine solar is a world's leading high-tech PV module manufacturer.With the advanced production lines,the company boasts module capacity of 613W.Bloomberg has listed ZNShine as a global Tier 1 PV module maker.Today Znshine has distributed its sales to more than 60 countries around the globe. Note:Specifications included in this datasheet are subject to change without notice.ZNSHINE reserves the right of final interpretation©ZNSHINE SOLAR 2022 1 Version:ZXM7-SH108 2203.E No special undertaking or warranty for the suitability of special purpose or being installed in extraordinary surroundings is granted unless as otherwise specifically committed by manufacturer in contract document PRODUCT DATASHEET N131D NORTHERN ELECTRIC BDM-600 MICROINVERTER SPECIFICATIONS BDM-300X2 CEC Listing as Utility Interactive Inverter (NC0141-US-BQ-A,NC0141-L-US-BQ-A) In ut(DC) Recommended Max PV Power: 400 W x 2 Max DC Open Circuit Voltage: 60 Vdc Max DC Input Current: 14 A x 2 MPPT Tracking Accuracy: >99.5% D ki MPPTTracn Ran e: 22-55Vdc .I ISC PV(Absolute Maximum): 18 A x 2 IT Maximum Backfeed Current to Arra . 0 A Output(AC) Peak AC Output Power: 580 W Max Continuous Output Power: 500 W Nominal Power Grid Voltage: 240 vac 3rp:208 vac Allowable Power Grid Voltage: 211-264 vac 3rp:183-228 vac Rated Output Current: 2.09 A 39:2.40 A Maximum Units Per Branch(20A): 7 units 3rp:6 units (All NEC adjustment factors considered) . STANDARD DIMENSIONS Allowable Power Grid Frequency, 59.3-60.5 Hz Inches THD: <3%(at rated power) Power Factor(cos phi,fixed): -0.99>0.9(adjustable) 1091• 1.97" Current(inrush)(Peak and Duration): 24A,15 US Nominal Frequency-. 60 Hz Max Output Fault Current: 2.4 Arms for 3 cycles Max Output Overcurrent Protection: 10 A System Efficiency Weighted Average Efficient (CEC): 95.5% ut Nighttime Tare Loss: 0.11 W Protection Function Over/Under Voltage Protection: Yes Over/Under Frequency Protection: Yes Anti-Islandin Protection: Yes Over Current Protection: Yes Reverse DC Polarity Protection: Yes Overload Protection: Yes Protection Degree: NEMA-6/IP-66/IP-67 Weight:6.4 lbs.(2.9 kg) Ambient Temperature: -40'F to+149'F(-40°C to+65'C) Operating Temperature: -407 to+185'F(-40°C to+85'C) Display: LED Light Certifications Communications: Powerline Communications UL 1741,CSA C22.2,NO.107.1,IEC/EN 62109-1,IEC/EN 62109-2,IEEE 1547, Environment Category. Indoor and outdoor VIDE-AR-N 4105',VDE V 0126-1-1/A1,G83/2,CEI 21,AS 4777.2,AS 4777.3, Wet Location: Suitable EN50438,ABNT NBR 1 61 49/1 61 50 Pollution Degree: PD 3 r 47A0 � r 3914- 480. Over Voltage Category. II(PV),III(AC MAINS) I All NEC required adjustment factors have been considered for AC outputs.AC current outputs will not exceed stated values for Rated output AC Current. 1 I I I COMPLIANCE 40.00' I NEC 2020 Section 690.11 DC Arc-Fault Circuit Protection Per box:5 pcs Pallet Qty:162 pcs NEC 2020 Section 690.12 Rapid Shutdown of PV Systems on Buildings Boxes per layer:8 Pallet weight 1072 lbs. • NEC 2020 Section 705.12 Point of Connection(AC Arc-Fault Protection) Layers:3 .11 t Lntertek AUTHORIZATION TO MARK lot..Q—hty.A3v."d. This authonzes the application of the Certification Mark(s) shown below to the models oescnbed in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report This authorization also applies to multiple I stee model(s) identified on the correlation page of the Listing Report Thrs document is the property of Interte-K Testing Services and is not transferable The certification marks)may be applied only at the location of the Party Authorized To Apply Mark Applicant: QINGDAO Northern Electric 8 Power Manufacturer SZZT Electronics Co.LTD Co.Ltd Bad.No.27.Airport International Center, No 6 Changcheng South Road. SZZT Industrial Park,No.3 Tongguan Address. CHENGYANG DISTRICT Orngdao Address: Road.Guangmong New District. 266109 SHENZHEN Guangdong P.R.Ginn P.R China Mr Fan Wang Mr.Fan Wang 0532-87963900 0532-87963900 0532-81100917 0532-81100917 fanw@nonhemep.com cn fanw�rlorthernep.com.cn Party Authorized To Apply Mark: Same as Manufacturer Report issuing Office: Intertek Testing Services Shenzhen Limited Guangzhou&anch or L.Maftweew Snyder. ier6#ce�nA nagea(� r- C % u8 .wna Intertek Thrs document supersedes all previous Authorizations to Mark for the noted Report Number. TV Atdwin E 1YI w b M w¢W�r•d i1Yltll O�1 rG w Y�Itl r.�.�•D M C/MQtn 4�.'wIr rr.n Inns rG 4 Crm dY1•ir♦n�lM!tK Ypr!A rYt b rI.rllr.N mWen O ff plvsN erne�swnr ne IrI n wry pw�aIw}II.b M[iwr w war.ro M M y+wtlrt b n1 MI wow.•a wvlq a�o.tl b1 M�d ww AJ.ww>e�!Irw ar/M Clwn•Wu1nO b pwl.r cgMlw w�wJv d M A.rI>swT IC IYw wG M w'N n w wfilfl W d wlwwl.CwNab nrn 1rlfsa e M aaOwan W et w M grrr�.K n tw Iutomb.b IYl M n.ww r.d M M1rr nww b b WI n tlwirrwsll N rlw�!nwwl pvi.e w rrwu n� fin d w(s.wf w nrV a IIIwYI wwr rwfwl M.wneY IIc IONS p Srrw�u b M P/Ivw Y wrwry wiw�rl uq d uw;.Irtrwn.wn n aolwc•w�.M q�M Pry w M b Y wwswl.I d vm.wnn wwwl and.rC Y na wnw ti[YA N MI uapwvw r.h vpC Intenek Testing Services NA Inc 545 East Algonquin Rood Arlington Heights.IL 60005 Telephone 800.345.3851 or 847-439-5667 Fax 312-283.1672 Inverters,Converters,Controllers And Interconnection System Equpment For Use W ith Distributed Standard(s): Energy Resources[UL 1741:2010 Ed.2*R-16Sep2020] Parrer Conversion Equipment(CSA C222#107.1:2016 Ed_4] hUcro Grid-connecled PV inverter Brand Name: NEP NORTHERN ELECTRIC BDM-250-240A-BOM-250-208A.BD1.1-300-240A.BDM-300-208A.BDM-300x2-240A.BOM-300x2- Models: 20&k BDM-500-240A.BDM-W&208A ATM for Report 170825096GZU-001 Page t of 1 ATM Issued:9-Aug-2021 snapnrack.com snapnrack.com Solar Mounting Solutions A'A SnapNrack SpeedSeaJTm Foot SnapNrack SpeedSeaJTm Foot Fastest Roof Attachment in Solar Patent Pending Lag Driven Sealant Solution for Ultra Pail • Lag straight to a structural member, no in-between components such as fleshings or bases. • Simply locate rafter, fill sealant cavity & secure to roof. A New Generation of Roof Attachments It's that simple/ Innovative design incorporates flashing reliability into a single roof attachment Integrated Flashings. No Questions. • 100% waterproof solution • Sealant fills around lag screw keeping roof and structure sealed and intact • Sealing cavity with compressible barrier • No added holes from ripping up nails, staples and secures sealant in place & fills voids screws holding shingles on roof Less Time. Less Parts. Less Tools. Maintain the Integrity of the Roof by Eliminating Disruption • Zero prying of shingles • No more need for a pry bar to rip • Zero removal of nails leaving holes in the roof up shingles • Roof remains installed the way manufacturer meant it to be • No more proprietary lag screws Lag Driven Sealant Waterproofing • Single Tool installation with '/2" — • Time Tested Roof Sealant provides lasting seal socket ;,, �u�,�'�� • Sealant is compressed into cavity and lag hole as attachment is secured to rafter Total System Solution • Active sealant solidifies bond if ever One Tool. One Warranty. _ touched by liquid • Technology passes UL 2582 Wind Driven • SnapNrack Ultra Rail is a Rain Test and ASTM E2140 Water Column straightforward intuitive install Testing standards. Patent Pending. experience on the roof without Single Tool Installation compromising quality, aesthetics & safety, all supported by a 25 year warranty. • SnapNrack was the first in the industry • Built-in Wire Management & Aesthetically pleasing features designed for Ultra Rail to develop a complete system that only result in a long-lasting quality install that installers and homeowners love. requires a single tool. That tradition is Certifications continued as a t/2" socket is still the only tool necessary to secure the mount as well - SnapNrack Ultra Rail System has been evaluated by Underwriters Laboratories (UL) and Listed to UL/ANSI Standard 2703 for Mechanical Loading and Fire. Additionally it is listed to UL 2582 as all other parts of the system. for wind-driven rain and ASTM 2140. SnapNrack Solar Mounting Solutions 877-732-2860 www.snapnrack.com contact@snapnrack.com Note:Sealant shown in white for illustration purposes only. ©2020 by SnapNrack Solar Mounting Solutions. All rights reserved DESCRIPTION: DRAWN BY: SNAPNRACK, UR-40 RAIL mwatkins Sna�Nmck- REVISION: i Solar Mong Solutions / �� \ MID CLAMP ASSEMBLY PART NUMBER(S): / B 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 94105 USA I I \ • / 232-02449, 232-02450, 232-02451 PHONE(415)580-6900 FAX(415)580-6902 THE INFORMATION IN THIS DRAWING S3 CONFIDENTIAL ANDPROPRIETARY. \ REPRODUCTION,DISCLOSURE,OR USE THEREOF PROHIBITED THE SOUTH WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. / SS BONDING PIN —�— — — MODULE UR-40 RAIL FRAME PROPERTIES / l SKU FINISH RAIL 232-02449 MILL \ / 232-02450 CLEAR \ 232-02451 BLACK CHANNEL NUT NOTE: 1. ADJUSTABLE END CLAMPS USE SAME BONDING PIN DESIGN TO BOND MODULES TO RAIL op 6-12 AWG BARE 5/16"-18 SS BOLT COPPER WIRE SS SPLIT LOCK WASHER 1.500 — (TORQUE TO 16 FT-LBS) i .750 / � � � SNAPNRACK GROUND LUG r, CHANNEL NUT .832 / RAIL SS BONDING SECTION PROPERTIES 1.624 + PINS A 0.357 in2 Ixx 0.125 in4 CENTROID NOTE: 1. ALL HARDWARE IS INCLUDED FROM MANUFACTURER Iyy 0.132 in4 2. A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY Sx (TOP) 0.150 in3 CONTINUOUS ROW OF MODULES Sx (BOT) 0.158 in3 792 3. GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ASSEMBLER: 4. GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR Sy (LEFT) 0.175 in3 PERPENDICULAR TO RAIL Sy (RIGHT) 0.175 in3 5. ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE INSPECTOR: ALL DIMENSIONS IN INCHES MATERIALS: 6000 SERIES ALUMINUM OPTIONS: DESCRIPTION: DRAWN BY: MIKE WATKINS SNAPNRACK MOUNTING SYSTEM APPROVED BY: CODY NORMAN Snap.Nrack DESIGN LOAD (LBS): N/A CLEAR/ BLACK ANODIZED REVISION: ULTIMATE LOAD (LBS): N/A MILL FINISH GROUNDING DETAILS G 1/11/2016 NEW ITEM Solar Mounting Solutions TORQUE SPECIFICATION: N/A LB-FT BUNDLES OF 144 _ Sunrun South LLC 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 94105 USA PHONE(415)580-6900•FAX(415)580-6902 PART NUMBER: SCALE: CERTIFICATION: UL 2703, FILE E359313 BOXES OF 8 — WEIGHT (LBS): 5.85 DNS = HERODUC ION, ISCL THIS DRAWING USE CONFIDENTIAL OHI PROPRIETARY.ANY REPRODUCTION,DISCLOSURE,OR USE THEREOF S PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. Grounding • • snapnrack.com Grounding Specificationssnapnrack.com Ilsco Lay-in Lug Assembly Ground Path Details-SolarEage En U �- -TO EGC SNAPNMK ULTRA SERIES RAIL IF 43 #10 NUT 55 WTfH STAR WASHER (�, O ILSCO GOL-0DBT GRMND WG V --'TO EGC #10 BOLT 55� o RAIL a RAIL SPLICE Ej MOUNT O GROUND LUG Q MODULE CLAMP COPPER WIRETYP. M=MIDCLAMP GROUND PATH L EQUIPMENT GROUNDING [ISOLAREDGE X=X-END CLAMP Ground Path Details CONDUCTOR OPTIMIZER U=UNIVERSAL END CLAMP Ground Path Details-Enphase 01 =TO EGC -TO EGC ED =TO EGC rb o RAIL a RAIL SPLICE 0 MOUNT O GROUND LUG Q MODULE CLAMP M-MIDCLAMP GROUND PATH 1 EQUIPMENT GROUNDING [IENPHASE X-X-END CLAMP RAIL a RAIL SPLICE MOUNT O GROUND LUG Q MODULE CLAMP =CONDUCTOR MICRO- U=UNIVERSAL END M=MIDCLAMP INVERTER CLAMP GROUND PATH 1 EQUIPMENT GROUNDING CONDUCTOR X=X-END CLAMP U=UNIVERSAL END CLAMP 58 Grounding Specificationsck.comGrounding Speccations INSTALLATION INSTRUCTIONS-SNAPNRACK GROUND LUG Ground Path Details- .:. El J VU FE 1)Snap the SnapNrack Ground Lug 2)Place grounding conductor Into 3)Tighten hardware to 16 ft-lbs. into the rail channel on one rail per slot underneath split ring washer. - - - module row. —1 TO EGC Install Note: �},?. Install Note: SnapNrack Ground Lug may be used SnapNrack Ground Lug only Listed in side or top channel,and may be for use with 6-12 AWG solid copper rotated 90 degrees relative to slot to conductor. "" •2 facilitate running copper across top •����of rails. INSTRUCTIONS • LAY-IN LUG —RAIL RAIL SPLICE 0 MOUNT GROUNDLUG MODULE CLAMP — DYNORA)O(DYNOBOND EQUIPMENT GROUNDING CONDUCTOR E END CLAMP GROUND PATH R/C(GIMS2),DynoRaxx(E357716)photovoltaic bonding jumper cat.no.DynoBond I�I11 is an optional component that may be used with this system.The DynoBond jumper LV1� has been evaluated to provide module to module bonding.The attaches to the frame flange of adjacent modules. DynoBond device 1)Drill and deburr a 1/4"hole In 2)Place grounding conductor Into 3)Tighten set screw per lisco's the back side of the rail for the slot. recommendation(see below). lisco lug to attach to,place the bolt through the hole,and attach the lug {�+, Install Note: assembly on one rail per module Torque set screw to 20 in-Ibs for#10- #14 solid and stranded copper,26 in-Ibs for#8 stranded copper,and 36 I nsta Note: in-Ibs for#4-#6 stranded copper. Torque 2il connection to 36 in-Ibs. •System has been evaluated to a maximum overcurrent device(OCD)protection level of 20 Amps. •Universal End Clamp(UEC)does not bond module to rail.Be sure to separately ground any modules that are only secured by UECs, especially during servicing. •SnapNrack recommerWs that bare copper never come into contact with aluminum. •SnapNrack Ground Lug:torque bolt to 16 ft-Ibs.The Ground Lug may be used in side or top channel.It may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. •Grounding with a standard Ilsco GBL-4DB7 Lug is a listed alternate and requires drilling of a hole in the rail. •Ilsco hardware connection to rail:6 ft-Ibs.Torque for lug set screw:#10-#14 solid and stranded copper-20 in-Ibs,#8 stranded copper-26 '' in-Ibs,#4-#6 stranded copper-36 in-Ibs. Grounding • • snapnrack.com Maintaining the Grounding Bonding When snapnrack.com Removing Module GROUNDING MARKING DETAILS JUMPER ASSEMBLY INSTRUCTION&INSTALLATION All components included in the Ultra Rail CAUTION:Do Not Remove the Module until the Jumper is installed UL 2703 Listing for grounding/bonding are packaged and marked with the UL logo, IIIIIIIIIIIIIIIIIIII�I IIII III SnapNrack File E359313,and"PV Mounting O �' 1)Identify the existing ground path System" 73.3-44MM at the location of module removal 2054 and choose an appropriate length of Example of assembled The SnapNrack Ground Lug is marked with . - #10 bare copper to bridge the soon bonding jumper using(2) D CLAMP,the ground symbol 30-1.77IN ��`.., ������ to be broken ground path. SnapNrack Ground Lugs I lsco Ground Lugs have green colored set aTy;2o screws or bolts to indicate connection to the grounding electrode conductor 2)Attach one ground lug to each INSTRUCTION FOR MAINTAINING THE GROUNDING BONDING WHEN REMOVING A end of#10 bare copper wire.See MODULE FOR SERVICING recommended options below: 1. (2)SnapNrack SKU:242-02101 CAUTION:Module removal may disrupt the bonding path and could introduce the risk of electric shock.Additional 2. (2)Ilsco part no. steps may be required to maintain the bonding path.Modules should only be removed by qualified persons in 3. (1)SnapNrack part n no.o.242-02101 compliance with the instructions in this manual. (1(1) part no.SGB-4 4. (1)DroRaRaxx DynoBond"" Module removal is not presented as a frequently expected occurrence and will not be required as part of routine maintenance. Scenarios that could result in a disruption of the bonding path are,for example irregularly-shaped arrays,arrays consisting of individual rows,and any other scenario where module removal could disrupt the bonding path. In most cases,the removal of a module for servicing will not disturb or break grounding continuity because SnapNrack Ultra Rail systems are bonded through the rail.If a module is to be removed that will break continuity, these are the steps that must be taken to maintain a continuously bonded SnapNrack Ultra Rail system. Required Tools Socket Wrench Torque Wrench 1/2"Socket 7/16"Socket 3)Before the module is removed,attach the assembled bonding jumper.Depending on where the module will be removed and choice of ground lug,jumper attachment locations will vary. • Ilsco SGB-4 lugs can be attached to SnapNrack Ultra Rail,or module frames Required Materials Q SnapNrack Ground Lug can only be attached to SnapNrack Ulra Rail Q#10 Or Larger Bare Copper Conductor Q DynoRaxx DynoBond-is approved and appropriate when a short bonding jumper is needed from module to module,or module to rail Q SnapNrack SKU 242-02101 Q Q Ilsco Part No.SGB-4 0 DnoRaxx Dynobond'" 4)Service the array.With the 5)After Servicing the array reinstall bonding jumper installed,it is now the module and original ground k$* safe to remove the module for path.Only then remove the bonding service or maintenance. jumper. Q Caution:Do not remove the bonding �. jumper until original ground path is established. 61 62 Grounding • • snapnrack.com Grounding Specificationssnapnrack.com Ultra Rail has been tested with the following UL Listed modules: Manufacturer Model The Ultra Rail System employs top-down clamps which have been evaluated for frame-to-system bonding,at specific mounting B.LINE PLUS BFR-G4.I-XXX Q.PEAK DUO-L-G6.2-XXX torques and with the specific modules listed below. B.LINE PRO BFR-G4.I-XXX Q.PEAK DUO-L-G6.3-XXX Ultra Rail has been tested with the following UL Listed module series:The Ultra Rail System employs top-down clamps which Q.BASE GY-XXX Q.PEAK DUO-L-GB-XXX have been evaluated for frame-to-system bonding,at specific mounting torques and with the specific module series listed Q.PEAK BFR-G4-XXX Q.PEAK DUO-L-G8.I-XXX below.All wattage values are covered. Q.PEAK BFR-G4.I-XXX Q.PEAK DUO-L-G8.2-XXX Manufacturer Model Q.PEAK BLK-G4.I-XXX Q.PEAK DUO-L-G8.3-XXX DNA-120-MF23-XXX DNA-120-BF26-XXXW Q.PEAK BLK-G4.1/TAA-XXX Q.PEAK DUO-G5/SC-XXX DNA-120-BF23-XXX DNA-144-BF26-XXXW Q.PEAK G4-XXX Q.PEAK DUO-BLK-G5/SC-XXX DNA-144-MF23-XXX DNA-108-BF10-xxxW Q.PEAK G4.1-XXX Q.PEAK DUO-G6+/SC-XXX Aptos Solar DNA-144-BF23-XXX DNA-120-BF10-xxxW Q.PEAK G4.1/MAX-XXX Q.PEAK DUO-BLK-G6+/SC-XXX DNA-120-MF26-XXXW DNA-108-MRO-xxxW Q.PEAK G4.1/TAA-XXX Q.PEAK DUO BLK-G6+/AC-XXX DNA-144-MF26-XXXW Q.PLUS BFR-G4-XXX Q.PEAK DUO-ML-G9-XXX Q.PLUS BFR-G4.I-XXX Q.PEAK DUO-BLK-ML-G9-XXX BVM6610P-XXX BVM6612P-XXX Q.PLUS BFR-G4.1/TAA-XXX Q.PEAK DUO-BLK-G9-XXX Boviet Solar BV M6610M-XXX BV M6612M-XXX Q.PLUS G4-XXX Q.PEAK DUO-BLK-G9+-XXX CS6K-XXX-M CS3U-XXX-MS Q.PLUS GY-XXX Q.PEAK DUO-ML-G9+-XXX CS6K-XXX-M-SD CS3U-XXX-P Q.PLUS BFR-GY-XXX Q.PEAK DUO-BLK-ML-G9+-XXX CS6K-XXX-P CS1K-XXX-MS Q.PRO BFR-G4-XXX Q.PEAK DUO-G5/TS-XXX CS6K-XXX-P-SD CS1H-XXX-MS Q.PRO BFR-G4.I-XXX Q.PEAK DUO BLK-G5/TS-XXX CS6K-XXX-MS CS1H-XXX-MS-AB Q.PRO BFR-G4.3-XXX Q.PEAK DUO-G6/TS-XXX CS6P-XXX-M CS3W-XXX-P Q.PRO BFR-GY-XXX Q.PEAK DUO BLK-G6/TS-XXX Canadian Solar CS6P-XXX-P CS3N-XXX-MS Q.PRO BLK-GY-XXX Q.PEAK DUO-G6+/TS-XXX Hanwha Q Cells Q.PRO G4-XXX Q.PEAK DUO BLK-G6+/TS-XXX CS6P-XXX-P-SD CS1Y-XXX-MS Q.PRO GY-XXX Q.PEAK DUO XL-G9.2-XXX CS6V-XXX-M CS3W-XXXMB-AG Q.PRO GY/SC-XXX Q.PEAK DUO XL-G9.3-XXX CS6V-XXX-P CS3Y-XXXMB-AG Q.PEAK DUO-GS-XXX Q.PEAK DUO XL-G9.3/BFG-XXX CS6X-XXX-P CS6W-XXXMB-AG Q.PEAK DUO-BLK-GS-XXX Q.PEAK DUO XL-G10.2-XXX CS3K-XXX-P CS6R-XXXMS-HL Q.PLUS DUO-GS-XXX Q.PEAK DUO XL-G10.3/BFG-XXX CS3K-XXX-MS CS3W-XXX-MS Q.PEAK DUO-G7-XXX Q.PEAK DUO XL-G10.3-XXX CertainTeed CTXXXHCII-06 Q.PEAK DUO-BLK-G7-XXX Q.PEAK DUO XL-G10.c-XXX CHSM6612M-XXX CHSM72M-HC-XXX*(Astro 4) Q.PEAK DUO-G7.2-XXX Q.PEAK DUO XL-G10.d-XXX Chint Solar CHSM6612M(BL)-XXX CHSM72M-HC-XXX*(Astro 5) Q.PEAK DUO-G6+-XXX Q.PEAK DUO L-G8.3/BFG-XXX CHSM6612M/HV-XXX Q.PEAK DUO-BLK-G6+-XXX Q.PEAK DUO L-G8.3/BGT-XXX DH-M760B-XXXW DH-M760E-XXXW* Q.PEAK DUO-G6-XXX Q.PEAK DUO ML-GIO-XXX Dehui Solar DH-M760W-XXXW DH-M772F-XXXW* Q.PEAK DUO-BLK-G6-XXX Q.PEAK DUO BLK ML-G10+-XXX DH-M772W-XXXW Q.PEAK DUO-G8+-XXX Q.PEAK DUO ML-G10+-XXX ET-P660XXXBB P660XXXWB/WW Q.PEAK DUO-BLK-G8+-XXX Q.PEAK DUO BLK ML-GI0-XXX ET Solar ET-P660XXXWB P660XXXWWG Q.PEAK DUO-G8-XXX Q.PEAK DUO ML-G10.a+-XXX ET-P660XXXWW M660XXXBB Q.PEAK DUO-BLK-G8-XXX Q.PEAK DUO BLK ML-G10.a+-XXX ET-P660XXXWWG M660XXXWW Q.PLUS L-G4-XXX Q.PEAK DUO ML-G10.a-XXX Freedom Forever FF-MP-BBB-xxx Q.PLUS L-G4.I-XXX Q.PEAK DUO BLK ML-G10.a-XXX Q.PEAK BLK-G3.I-XXX Q.PEAK DUO-L-G7.2-XXX Q.PLUS L-G4.2-XXX Q.PEAK DUO BLK ML-G10.a+/7S-XXX Hanwha Q Cells Q.PEAK G3.1-XXX Q.PEAK DUO-L-G7.3-XXX Q.PEAK L-G4.I-XXX Q.PEAK DUO G10-XXX Q.PLUS BFR-G3.I-XXX Q.PEAK DUO-L-G6-XXX Q.PEAK L-G4.2-XXX Q.PEAK DUO BLK G10-XXX 63 Q.PLUS DUO-L-GS-XXX Q.PEAK DUO G10+-XXX Grounding • • snapnrack.com Grounding Specificationssnapnrack.com Manufacturer Model Manufacturer Model Q.PLUS DUO-L-G5.I-XXX Q.PEAK DUO BLK G10+-XXX LGXXXSIC-A5 LGXXXNIK-L5 Q.PLUS DUO-L-G5.2-XXX Q.PEAK DUO BLK G10+/AC XXX LGXXXN2C-B3 LGXXXNIK-A6 Q.PLUS DUO-L-G5.3-XXX Q.PEAK DUO BLK G10+/HL XXX LGXXXN2W-B3 LGXXXNIC-A6 Hanwha Q Cells Q.PEAK DUO-L-G5.2-XXX Q.PEAK DUO XL-G11.3 XXX LGXXXNIC-G4 LGXXXNIW-A6 Q.PEAK DUO-L-G5.3-XXX Q.PEAK DUO XL-GII.3 BFG XXX LGXXXNIK-G4 LGXXXQIC-A6 Q.PEAK DUO-L-G7-XXX Q.TRON-GI+XXX LGXXXSIC-G4 LGXXXQIK-A6 Q.PEAK DUO-L-G7.I-XXX Q.TRON BLK-GI+XXX LGXXXN2C-G4 LGXXXMIK-A6 Hanwha SOlarOne HSL60P6-PB-2-XXXQ HSL60P6-PB-4-XXXQ LG LGXXXN2K-G4 LGXXXMIC-A6 60M-XXX 72M-XXX LGXXXN2W-G4 LGXXXAIC-A6 Heliene 60P-XXX 72P-XXX LGXXX52C-G4 LGXXXQAC-A6 HT-SAAE HT60A66M-XXX HT60-182M-XXX LGXXXS2W-G4 LGXXXQAK-A6 HiS-MXXXRG HiA-SXXXMS LGXXXNIC-V5 LGXXXNIK-B6 HiS-SXXXRG HiS-SXXXXY LGXXXNI W-V5 LGXXXN2 W-E6 HiS-SXXXRW HiS-SXXXYI LGXXXN2T-V5 LGXXXN2T-E6 Hyundai LGXXXN2T-J5 LGXXXNIK-E6 His-MXXXMG His-SxxxYH(BK) HiS-SXXXMG All may be followed by(BK) LGXXXNIT-V5 LGXXXN3K-V6 HiD-SXXXRG LR6-60-XXXM LR4-60HPB-XXXM Hyperion/Runergy HY-DH108P8-XXX(Y) LR6-60BK-XXXM LR4-60HIB-XXXM JAM6-60-XXX/SI JAM72SIO-XXX/MR LR6-60HV-XXXM LR4-60HPH-XXXM JAP6-60-XXX/3BB JAM72S10-XXX/PR Longi LR6-60PB-XXXM LR4-60HIH-XXXM JAM60509-XXX/PR JAM72512-XXX/PR LR6-60PE-XXXM LR6-60HIH-XXXM JAM60S10-XXX/M R JAP6(k)-72-XXX/4BB LR6-60PH-XXXM LR6-60HI B-XXXM JA Solar JAM60SlO-XX)(/PR JAM60Sl7-XX)(/MR LR6-60HPB-XXXM LR4-72HPH-XXXM JAM60S12-XXX/PR JAM54S30-XXX/MR LR6-60HPH-XXXM JAP72SOI-XXX/SC JAM54S31-XXX/MR Meyer Burger Meyer Burger Black* Meyer Burger White* JAM72SO9-XX)(/PR JAM72D30-XXX/MB mSolar TX16-XXXI20BB JKMXXXM-60 JKMXXXP-72-V MSEXXXS05T MSEXXXSR8K JKMXXXM-60L JKMXXXPP-72 MSEXXXS05K MSEXXXSR8T JKMXXXM-60HL JKMXXXPP-72-V MSEXXXS05T MSEXXXSR9S JKMXXXM-60HBL JKMSXXXP-72 MSEXXXS05K MSE60AXXX JKMXXXP-60 JKMXXXM-72HL-V MSEXXXMM4J MSEXXXTS60 JKMXXXP-60-J4 JKMXXXM-72HL-TV Mission Solar MSEXXXMM6J MSEXXXSX5K Jinko Solar JKMXXXP-60-V JKMXXXM-72HBL MSEXXXS06W MSEXXXSX5T JKMXXXP-60B-J4 JKMXXXM-6TL3-B MSEXXXSO4J MSEXXXSX6S JKMXXXPP-60 JKMXXXM-6RL3-B MSEXXXS06J MSEXXXSX6W JKMXXXPP-60-V JKMXXXM-7RL3-V MSEXXXS06S MSExxxSX5R JKMXXXM-72 JKMXXXM-7RL3-TV MSEXXXS04S JKMXXXM-72L-V JKMXXXM-72HL4-V USNEA-XXXM3-60 USNEA-XXXM3-72 JKMXXXP-72 JKMXXXM-72HL4-TV Next Energy Alliance USNEA-XXXM3B-60 USNEA-XXXM3B-72 Kyocera KUXXX-6YYY KUXXX-8YYY VBHNXXXKA01 VBHN325SA17E LGXXXNIC-A5 LGXXXAIC-V5 VBHNXXXKA02 VBHXXXRA18N LGXXXNIK-A5 LGXXXMIC-L5 Panasonic LG VBHNXXXSAI6 VBHXXXRA03K LGXXXQIC-AS LGXXXMIK-LS LGXXXQIK-A5 LGXXXNIC-N5 VBHNXXXKA03 EVPVXXX(K) 65 66 Grounding • • snapnrack.com Grounding Specificationssnapnrack.com Manufacturer Model Manufacturer Model VBHNXXXKA04 EVPVXXXH Solaria PowerXT-XXXR-PX Solaria PowerXT-XXXR-PM Panasonic VBHNXXXSA17 EVPVXXXPK Solaria Solaria PowerXT-XXXR-BX Solaria PowerXT-XXXR-PM-AC VBHNXXXSA18 Solaria POwerXT-XXXR-AC PSXXXM-20/U PSxxxM8GF-18/VH SOIarWOrld SWXXX-Mono SWXXX-Mono XL Phono Solar PSXXXMH-20/U PSxxxM8GFH-18/VH MVX-XXX-60-5-701 OPT-XXX-60-4-1BO PSxxx M8GF-24/TH PSxxxM6-24/TH Suniva MVX-XXX-60-5-7B1 OPT-XXX-60-4-800 PSxxxM8GFH-24/TH OPT-XXX-60-4-100 OPT-XXX-60-4-8B0 RECXXXPE RECXXXTP2M 72 BLK2 SPR-EW-XXX SPR-AXXX RECXXXPE-BLK RECXXXTP2SM 72 SPR-XYY-XXX SPR-AXXX-BLK-G-AC RECXXXTP RECXXXTP2SM 72 BLK SPR-EYY-XXX SPR-AXXX-BLK RECXXXTP-BLK RECXXXTP2SM 72 BLK2 Sunpower SPR-XYY-XXX SPR-MXXX-H-AC RECXXXTP IQ RECXXXAA SPR-PI7-XXX-COM SPR-MXXX RECXXXTP2 RECXXXTP3 SPR-PI9-XXX-COM SPR-MXXX-BLK-H-AC REC RECXXXTP2-BLK RECXXXTP3M SPR-AXXX-G-AC SPR-MXXX-BLK RECXXXNP RECXXXTP4 SST-XXXM3-60 SST-XXXM3-72 RECXXXTP2M RECXXXAA Pure SunSpark SST-XXXM3B-60 SST-XXXM3B-72 RECXXXTP72 RECxxxAA Pure-R TP660M-XXX TP672M-XXX RECXXXPE72 RECXXXNP2 Talesun TP660 P-XXX TP672P-XXX RECXXXPE72XV RECxxxNP3 Tesla TXXXS TXXXH RECXXXTP2M 72 All may be followed by BLK Or BLACK TSM-XXXDD05(II) TSM-XXXDD06M.05(II) RECXXXTP2M 72 BLK TSM-XXXDDOSA.OS(II) TSM-XXXDEISH(II) Renesola JCXXXM-24/Bb JCXXXM-24/BBh TSM-XXXDD05A.08(II) TSM-XXXDEI5M(I I) SEG Solar SEG-400-BMB-HV SEG-xxx-BMD-HV TSM-XXXDD05A.082(II) TSMXXXDD05H.05(I I) SEG-400-BMB-TB SEG-xxx-BMD-TB TSM-XXXPA05 TSMXXXDE06X.05(II) SLAXXX-M SILXXXNT TSM-XXXPA05.05 TSMXXXDE09.05 SLAXXX-P SILXXXHL TSM-XXXPA05.08 TSMXXXDEI5V(II) SSAXXX-M SILXXXBK Tri na TSM-XXXPD05 TS MXXXDEGI5 VC.20(II) SSAXXX-P SILXXXHC TSM-XXXPD05.002 TSMXXXDEGI8MC.20(II) SILXXXBL SILXXXNU TSM-XXXPDO5.05 TSM-XXXDE19 Silfab SILXXXML SILXXXNX TSM-XXXPD05.05S TSMXXXDEG19C.20 SILXXXNL SILXXXHN TSM-XXXPD05.08 TSMXXXDEG21C.20 SLGXXX-M SILXXXBG TSM-XXXPD05.082 TSMXXXDE09C.05 SLGXXX-P SIL-xxxHC+ TSM-XXXPD05.08D TSMXXXDE09C.07 SSGXXX-M SIL-xxxHM TSM-XXXPD05.08S TSM-xxxNE09RC.05 SSGXXX-P 67 68 Grounding • • snapnrack.com Mechanical Loading Specificationssnapnrack.com Manufacturer Model Ultra Rail has been tested with the following Module Level Power Electronic(MLPE)devices: SOMERA VSMHBB.60.XXX.05 PREXOS VSMDHT.60.XXX.05 The UR-40 and UR-60 mounting systems have been tested with the following UL/NRTL Listed Module Level Power Electronic Vikram Solar (MLPE)Devices.The back plates of the MLPEs have been evaluated for bonding to UR-40 and UR-60 rail through the MLPE SOMERA VSMH.72.XXX.05 PREXOS VSMDHT.72.XXX.05 Attachment Kit. VSUNXXX-144BMH-DG VSUNXXX-108BMH VSUN VSUNXXX-120BMH AP Smart RSD-S-PLC Yingli YLXXXA-29b YLXXXP-29b Celestica International DG-006-F001201x DG-006-F001401x Delta Electronics GPI00010105 ZNShine ZXM6-60-XXX/M ZXM6-NH144-XXXM C250 107PLUS-72-2-US ZXM6-NH120-XXXM ZXM7-SH108-XXXM M215 107PLUS-72-B-US M250 108-60 Enphase 106-60-2-US 108PLUS-72 106PLUS-72-2-US 108A-72 107-60-2-US I081-1-208-72 I07-60-B-US I081-1-240-72 Generac Optimizer model S2502 Ginlong Technologies Solis-RSDAG Solis-MLRSD-R2-iG Solis-MLRSD-R1-iG P300-5NC4ARS P505 P320-5NC4ARS P730 P370-5NC4AFS P800p P400-5NC4AFS P850 P320 P860 SolarEdge P340 P950 P370 PTIOO P400 PTIOI P401 S440 P405 S500 P485 SMA RSB-2S-US-10 TS4-R-F TS4-R-S-DUO TS4-R-M TS4-A-F TS4-R-O TS4-A-2F Tigo TS4-R-S TS4-A-0 TS4-R-M-DUO TS4-A-S TS4-R-0-DUO Notes: AP Smart RSD-S-PLC,Ginlong Solis-MLRSD-RI-IG and Solis-MLRSD-R2-1G,and all Tigo models have not been investigated for bonding since the enclosures are constructed entirely of polymeric materials. The SolarEdge P320 and P370 models are both frame mount and rail mount.All other PXXX series models are rail mount. 69 70 ©Em,TeN 2016 Eaton. All rights reserved. Powering Business Worldwide pe.eaton.com General Duty Cartridge Fuse Safety Switch DG221 NRB UPC:7821 1 31 2031 7 Dimensions: • Height: 6.25 IN • Length: 5.73 IN • Width: 6.1 IN Weight:5 LB Notes:Maximum hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: Specifications: • Type: General Duty/Cartridge Fuse • Amperage Rating: 30A • Enclosure: NEMA 3R • Enclosure Material: Painted galvanized steel • Fuse Class Provision: Class H fuses • Fuse Configuration: Fusible with neutral • Number Of Poles: Two-pole • Number Of Wires: Three-wire • Product Category: General Duty Safety Switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Drawing Dataset • Eaton Specification Sheet - DG221 NRB Certifications: • UL Listed Product compliance: No Data