HomeMy WebLinkAboutCHAD ZDROIK permit plans ALL
ENERGY
COMPANY INFORMATION
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
CHAD ZDROIK
580 RICE CREEK TER NE
FRIDLEY, MN 55432-4472
PO 79672
SYSTEM DETAILS
TOTAL:(22)REC REC420AA
420W BOB SOLAR MODULE
420W MODULES=9.24kW
(22) REC REC420AA 420W BOB
SOLAR MODULE 420W MODULES
=9.24kW
o
�I
REVISIONS
AK LAST: 11/08/2023
r
SHEET TITLE
COVER PAGE
SHEET NUMBER
PV-02 2
SOUTH ELEVATION ALL
ENERGY
COMPANY INFORMATION
MAXIMUM ROOF HEIGHT ALL ENERGY SOLAR, INC
1264 ENERGY LANE
MAXIMUM ARRAY HEIGHT ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
CHAD ZDROIK
580 RICE CREEK TER NE
FRIDLEY, MN 55432-4472
m �
N N PO 79672
SYSTEM DETAILS
NOTES:
1. ELEVATIONS MAY VARY
DEPENDING ON GROUND
ELEVATION BUT ARE DRAWN TO
THE BEST OF OUR ABILITY.
(22)REC REC420AA 420W BOB
SOLAR MODULE 420W MODULES
=9.24kW
----------------------------------------------------------------------------------------------------------------
WEST ELEVATION
D
REVISIONS
AK LAST: 11/08/2023
N �
N N
SHEET TITLE
ELEVATION
DRAWINGS
SHEET NUMBER
PV-03 3
2 5 6 7 8
ALL
TOTAL ROOF SURFACE AREA(PLAN VIEW); 18 3 7,S q ft E N E R G lr
TOTAL SOLAR MODULE SURFACE AREA(PLAN VIEW); 444,2Sgft
COMPANY INFORMATION
SOLAR PANELS COVERAGE PERCENT; 24.18%
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
CHAD ZDROIK
580 RICE CREEK TER NE
FRIDLEY, MN 55432-4472
PO 79672
SYSTEM DETAILS
TOTAL:(22)REC REC420AA
420W BOB SOLAR MODULE
420W MODULES=9.24kW
(22)REC REC420AA 420W BOB
SOLAR MODULE 420W MODULES
=9.24kW
36" FIRE
ACCESS
PATHWAY
18" FIRE RIDGE SETBACK
l�
36" FIRE ACCESS
PATHWAY
0 0
O p
i
0 0 REVISIONS
I
AK LAST: 11/08/2023
SHEET TITLE
N PROPERTY MAP
SHEET NUMBER
PV-04 4
2 1 3 1 4 1 5 1 6 1 7
1 2 1 3 4
MOUNTING MATERIALS ALL
TY NAME COMMENTS ENERGY
18 SNAPNRACK 232-02538 172IN BLACK UR-40 RAIL REC REC420AA 420W BOB SOLAR MODULE
10 SNAPNRACK 242-01214 UR-40 BLACK RAIL SPLICE COMPANY INFORMATION
A 6 SNAPNRACK 242-02101 6-12AWG GROUND LUG A
32 SNAPNRACK 242-02071 UR BLACK MID CLAMP Dimensions: 68.1 x 44 x 1 .2" ALL ENERGY SOLAR, INC
24 SNAPNRACK 242-02215 UNIVERSAL END CLAMP 1264 ENERGY LANE
24 SNAPNRACK 232-02452 UR-40 END CAP Clamping Zones: Long Side: 11 .41/20.4" ST PAUL, MN 55108
5 ISNAPNRACK 242-02150 UNIVERSAL WIRE CLAMP (800) 620-3370
22 SNAPNRACK 232-01106 WIRE RETENTION CLIP Short Side: 7.9/11 INFO@ALLENERGYSOLAR.COM
22 SNAPNRACK 242-92093 MLPE RAIL ATTACHMENT KIT CLIENT INFORMATION
52 SNAPNRACK 242-02174 BLACK SPEEDSEAL DECKFOOT Roof Attachments
208 SNAPNRACK 242-02175 #14X2-3/4IN STEEL SEALING WASHER DECKFOOT SCREW Roof Attachments CHAD ZDROIK
4 CHEMLINK F1270BL 10OZ POLYETHER M-1 ADHESIVE SEALANT Roof Attachments 580 RICE CREEK TER NE
FRIDLEY, MN 55432-4472
B PO 79672
SYSTEM DETAILS
15'-6"
TOTAL:(22)REC REC420AA
420W BOB SOLAR MODULE
420W MODULES=9.24kW
ARRAY 1:
•(16)REC 420 MODULES=6.72kW
O •14°TILT, 143°AZIMUTH
11'-2
iD
ARRAY 2:
"
•(6)REC 420 MODULES=2.52kW
•14°TILT,233°AZIMUTH
c
3'-4"
39'-9" O
^' III III III III III
*STRINGING SUBJECT TO
L I iI CHANGE ON SITE
qI� I I 1 -6 REVISIONS
I I AK LAST: 11/08/2023
ARRAY 1 I �, Ln
I I I I I O
CD
I � � � IIIIIIIIIIII IIIIIIIIIIIII � � � � � � � � � � � �
l I I l l l l l l l l I SHEET TITLE
II IIIIIIII IIIIIIIIIIIIIIIIIIIII
33'-6" 9'-10" N ARRAY LAYOUTS
E
69'-10"
SHEET NUMBER
PV-05 5
1 2 3 1 5 6 7
7 8
NOTES: ALL
LABELS LOCATED ON PV PRODUCTION METER, BI- ENERGY
DIRECTIONAL/UTILITY METER, AC DISCONNECT, INVERTER(S), 1. LOCATION OF SERVICE PANEL AND ELECTRICAL
AND APPROPRIATE LABELS ON MAIN ELECTRIC SERVICE. ALL EQUIPMENT ARE SHOWN. FINAL LOCATION MAY
LABELS ARE PERMANENT, WEATHERPROOF, AND DURABLE. CHANGE COMPANY INFORMATION
THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD 2. LOCATION OF SERVICE PANEL AND ADDITIONAL ALL ENERGY SOLAR, INC
POWERLINES. ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE
1264 ENERGY LANE
S: ST PAUL, MN 55108
DISTANCE
3.AC DISCONNECT AND PRODUCTION METER WITHIN (800) 620-3370
SOLAR PANELS- MICROINVERTER(S): 5' 10'OF MAIN SERVICE METER/BI-DIRECTIONAL INFO@ALLENERGYSOLAR.COM
MICROINVERTER(S) - IQ COMBINER: 75' METER. 24/7 UNESCORTED KEYLESS ACCESS TO BE
IQ COMBINER- UTILITY AC DISCONNECT: 5' PROVIDED FOR ALL UTILITY EQUIPMENT. CLIENT INFORMATION
UTILITY AC DISCONNECT- PV PRODUCTION METER: 5' 4. PV EQUIPMENT SHALL BE INSTALLED IN
PV PRODUCTION METER-AC DISCONNECT PV SERVICE: ACCORDANCE WITH NEC 690 AND POSTED WITH MATTHEW DEATES
5' APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES 580 RICE CREEK TER NE
AC DISCONNECT PV SERVICE- UTILITY METER: 5' _`� PER NEC 705-10, 690-17, &690-64(b)(5). FRIDLEY, MN 55432-4472
UTILITY METER- MAIN SERVICE PANEL: 5' �1
IS
CALL-OUTS: ,C�i� NTERCONNEICOTIONASEOONDARY PO 79672
1: SOLAR PANELS SYSTEM DETAILS
2: MICROINVERTER(S)
3: IQ COMBINER TOTAL:(B SOLAR
RMODULE
4: UTILITY AC DISCONNECT G 420W BOB SOLAR MODULE
420W MODULES=9.24kW
5: PV PRODUCTION METER
6: AC DISCONNECT PV ARRAY 1:
SERVICE �`� •(16)REC 420 MODULES=6.72kW
•14°TILT, 143°AZIMUTH
7: UTILITY METER
8: MAIN SERVICE PANEL O ARRAY 2:
•(6)REC 420 MODULES=2.52kW
•14°TILT,233°AZIMUTH
O
ACCOUNT: 51-0014147561-5
0 0 O PREMISE: 302838021
MADISON ST NE METER: 88433945
CASE #5604660
0 0 790 -� REVISIONS
AK LAST: 11/08/2023
1
6
5
tk
� Lti�
SHEET TITLE
N ELECTRICAL
SITE MAP
SHEET NUMBER
PV-06 61
7
1
(NEW)SOLAR PANELS ALL
(22) REC REC420AA 420W BOB SOLAR MODULE REC REC420AA 420W BOB ENERGY
MODULE DETAILS: SOLAR MODULE
COMPANY INFORMATION
A (NEW)MICROINVERTER(S) Rated Power @ STC: 420W
ALL ENERGY SOLAR, INC
(22)IQ7X-96-2-US(240V)INVERTERS 0
(75) 3/4"FMC: VMP: 50 1264 ENERGY LANE
(4)#10 AWG CU THWN,(1)#10 AWG CU THWN NEU,(1)#10 ST PAU L, M N 55108
AWG CU THWN GND (800) 620-3370
15.72A CONT.,1.22%VOLTAGE DROP,24.77%CONDUIT FILL IMP: 8.4 INFO@ALLENERGYSOLAR.COM
(NEW)IQ COMBINER:
.... 80A ENPHASE EN-X-IQ-AM1-240-4 IQ COMBINER W/ VOC: 59.4 CLIENT INFORMATION
Q CT/PAIR
Main Lug Only With
Qty(2)EATON BR220 20A/2P BR CIRCUIT BREAKER ISC: 8.89 MATTHEW DEATES
o° SEE LABELS ON FOLLOWING PAGE(S):8; 13; 14; 16; 580 RICE CREEK TER NE
Q o: FRIDLEY, MN 55432-4472
W Dimensions: 68.1 x 44 x 1.2"
e N z
INVERTER DETAILS: IQ7X-96-2-US (240V) PO79672
SYSTEM DETAILS
(s) 3/4"EMT: Rating: 315 ACCOUNT:51-0014147561-5
(2)#8 AWG CU THWN,(1)#10 AWG CU THWN NEU,(1)#10 AWG
CUTHWNGND CEC Efficiency. 97.5 % PREMISE:302838021
28.82A CONT.,0.09%VOLTAGE DROP,22.03%CONDUIT FILL METER:88433945
RpA Max DC Voltage: 80 CASE#5604660
DC SYSTEM SIZE: 9.24kW
/PoC
Max AC Output Current: 1.31 MAXIMUM POWER: 6.93kW AC
(NEW)UTILITY AC DISCONNECT: p OPERATING VOLTAGE: 120/240V
VISIBLE-OPEN TYPE, LOCKABLE,AND READILY MAX CURRENT @
ACCESSIBLE Nominal Voltage Range: 240 V/ 211-264 V (1-Phase) OPERATING VOLTAGE: 29A
60A NON-FUSIBLE 2P 240V NEMA 3R NOTES:
G SEE LABELS ON FOLLOWING PAGE(S): 10; 14; 15; 16;
18;8;20 Nominal Frequency: 60 Hz 1.DESIGN MEETS NEC CODE
AND SHALL BE INSTALLED IN
ACCORDANCE WITH NEC 690
(5) 3/4"EMT:
AND POSTED WITH APPLICABLE
(2)#6 AWG CU THWN,(1)#6 AWG CU THWN NEU,(1)#6 AWG
CU THWN GND TO UTILITY WARNINGS, SIGNAGE,AND
28.82A CONT.,0.00%VOLTAGE DROP,38.63%CONDUIT FILL PLAQUES PER NEC 705-10, 690-
17, &690-64(b)(5)
2.SOLAR MODULES, INVERTERS,
(NEW)PV PRODUCTION METER: LINE AND CORRESPONDING
LINE UTILITY-OWNED;W/BYPASS;200A 1 Ph 3W 120/240V (EXISTING)MAIN SERVICE PANEL: ELECTRICAL EQUIPMENT ARE
SEE LABELS ON FOLLOWING PAGE(S):21 LOCATION: INSIDE LISTED.
SQUARED
kWh 20/240V 1 Ph 3W
MAIN OCPD 125 AMP BUS 3.INVERTERS ARE UL 1741
kWh 1 0
TED
D LOAD NO WORK HERE
SEE LABELS ON FOLLOWING PAGE(S): 14; 16;40 REVISIONS
POINT OF COMMON COUPLING: AK LAST: 11/08/2023
(s) 3/4"EMT: LOAD LINETAP INSIDE MILBANK METER SOCKET
(2)#6 AWG CU THWN,(1)#6 AWG CU THWN NEU,(1)#6 AWG VIA UL LISTED K4977 TAP CONNECTORS.
CUTHWNGND INSTALLATION IS A SECONDARY
28.82A CONT.,0.00%VOLTAGE DROP,38.63%CONDUIT FILL
(EXISTING)UTILITY METER: INTERCONNECTION
UTILITY OWNED W/BYPASS;
MAIN 200 AMP 120/240V 1 Ph 3W
+LINE TAP IN METER SOCKET SHEET TITLE
SEE LABELS ON FOLLOWING PAGE(S):41;42
ELECTRICAL
G4_1
LINE DIAGRAM
(NEW)AC DISCONNECT PV SERVICE: (s) 1"PVC:
60A FUSIBLE 2P 240V NEMA 3RL THWN A EWG U(1)#6AWG1CU THWN GND SHEET NUMBER
SEE LABELS ON FOLLOWING PAGE(S): 28.82A CONT.'0.00%VOLTAGE DROP,
14;31;35 31.66%CONDUIT FILL PV 0 7
7
s
1 2 3 5 6 1 7
• • • 6 NOTE: LABELS ARE FOR ALL ARNING :
PHOTOVOLTAIC
GENERAL REFERENCE. ENERGY
NOT ALL LABELS ARE USED
OWER
SOURCE
• FOR EVERY INSTALLATION. COMPANY INFORMATION
A
ALL ENERGY SOLAR, INC
5: EXPOSED DC CONDUIT JUNCTION BOXES ECT. � , • � 7 1264 ENERGY LANE
10
ST PAUL, MN 55108
RAPID
SHUTDOWN
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
FOR
SOLAR
PV CLIENT INFORMATION
MATTHEW DEATES
A WARNING $� FRI RICE CREEK TER NE
• • • 13 FRIDLEY, MN 55432-4472
ELECTRICAL SHOCK HAZARD PO 79672
6 ' ' � DO NOT TOUCH TERMINALS SYSTEM DETAILS
TERMINALS ON BOTH LINE AND
A WARNING DUAL POWER SOURCE 14 LOAD SIDES MAY BE ENERGIZED
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION
_Ir 15PHOTOVOLTAIC •
OPERATINGMAINMAXIMUM AC c
NOMINALOPERATING •
SYSTE niSCONN
20
INTERCONNECTION
• 17 LABELS ARE WEATHERPROOF,
PV DURABLE, PERMANENTLY
MOUNTED,AND COMPLY WITH NEC
SOLAR PV SYSTEM EQUIPPED 35 DISCONNECT PRODUCTION 690.
I METER ACCOUNT: 51-0014147561-5
21
WITH RAPID SHUTDOWN A WARNING 36 PREMISE: 84339 5
21 METER: 88433945
POWER SOURCE OUTPUT CONNECTION. DO NOT CASE #5604660
RELOCATE THIS OVERCURRENT DEVICE. REVISIONS
TURN RAPID SHUTDOWN HOUSEAK LAST: 11/08/2023
SWITCH TO THE
CAUTION 37 METER
"OFF" POSITION TO IQ
PV SYSTEM CIRCUIT BREAKER IS BACKFED41
SHUT DOWN PV SYSTEM SHEET TITLE
AND REDUCE CAUTION : SOLAR ELECTRIC LABELS 1 E
SHOCK HAZARD SYSTEM CONNECTED
IN THE ARRAY SHEET NUMBER
42 PV-08
81
1 5 6 1 7
15 NOTE: LABELS ARE FOR
� ALL
DUAL POWER SOURCE GENERAL REFERENCE. ENERGY
DISCONNECT
NOT ALL LABELS ARE USED
EMERGENCY O
PHTOVOLTAIC
FOR EVERY INSTALLATION. COMPANY INFORMATION CIRCUIT
A
SERVICE ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
OPERATING VOLTAGE : • • (800) 620-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
MAXIMUM CURRENT: 29A
MATTHEW DEATES
580 RICE CREEK TER NE
INTERCONNECTION 17MAXIMUM 6 . 93kW AC
FRIDLEY, MN 55432-4472
PO 79672
DISCONNECT43 SYSTEM DETAILS
■
VOLTAGEMAXIMUM
22
CAUTION .
MAXIMUM CIRCUIT CURRENT
MULTIPLE SOURCES OF POWER-
MAX
RATED OUTPUT CURRENT OF
THE CHARGE CONTROLLER
• - D • DCONVERTER
LABELS ARE WEATHERPROOF,
DURABLE, PERMANENTLY
MOUNTED,AND COMPLY WITH NEC
690.
ACCOUNT: 51-0014147561-5
. 24 PREMISE: 302838021
SOLAR ARRAY METER: 88433945
CASE #5604660
O REVISIONS
PV COMBINER O PV COMBINER PANEL AK LAST: 11/08/2023
0
PANEL ONLY O UTILITY PV DISCONNECT
NO LOADS Q ° o PV SERVICE DISCONNECT
O o HOUSE SERVICE DISCONNECT
° ° (INDOOR) N
SHEET TITLE
LABELS 2
All Energy Solar E
www.allenergysolar.com
(800) 620-3370 SHEET NUMBER
18 PV-09
9
s