Loading...
HomeMy WebLinkAboutElectric One Line and Schedules_ AA04 - Solar By Us_Safdar Ali Haideri INVERTERS(SOLAREDGE) ♦ 65............... ...........� (1)SE6000H-US,6000W r............................................ r���������������������������������������������� INTERNET 240V,25A,1Qf Network Communication to ACCESS 0 10 To 10 TOTAL:6KW AC,25A Customer Owned Router +••••••••••••••••r : oc oc UL 1741 CERTIFIED CONDUCTOR$AND y JBOXTYPIIZ;AL �� ♦ 80 i I ^ 40 ...... ... 46 .................. ` i INVERTER 1 ....................... i ROOFTOP AREAS """'ti................................................ """ """""""""""""""""""r EXT. SOUTH SIDE OF HOUSE SERVICE PANEL SQUARE D -__ __--- ' i ' 240VAC,100A,1Qf OCP:100A � INTERIOR i DC-DC OPTIMIZERS:(SOLAREDGE) (16)SE S440,440W 1 MOD.PER OPTIMIZER REQUIREMENTS EACH STR: MAIN METER PV MAX 6000W 8-14 PV MODULES UTLITY OWNED UTILITY AC DISCONNECT 8-25 OPTIMZERS VISIBLE-OPEN TYPE BIDIRECTIONAL 2 STR PER INV 1:(PV 8,8) LOCKABLE,NEMA 3R 240V,200A,10,3-WIRE READILY ACCESSIBLE DIRECT MEASURE EXISTING MILBANK W/BYPASS PV MODULES W/PROTECTIVE BARRIERS Q-Cells SERVICE RATED (16) Q.PEAK DUO BLK ML-10+405 60A, 2-POLE STC:405,MPV:37.39,MPI:10.83 FUSINNGG OPTIPTIONAL:40A VOC:45.34,ISC:11.17 DISCONNECT TO MAIN ETER:4' TOTAL:6.48KW DC ` ♦--------------- ------- 70 ••• i i RPA (Reference Point of Applicability): 1 i PoC(Point of DER Connection) ------------- LOCATED AT INVERTER CONNECTION 93 ....... ......... ANTI-ISLANDING TEST POINT 62 SPD 85 I : 94 M + M 1T PRODUCTION METER UTILITY OWNED 7 �i 73 90 O NE-WAY 240V,200A,10,3-WIRE DIRECT MEASURE SOCKET W/BYPASS GENERAL NOTES: SOLAR TO LINE SIDE --DESIGN MEETS ALL NEC REQUIREMENTS --GROUNDING CONDUCTORS MAY NOT BE SHOWN TAG 90IN --REFER TO ELECTRICAL LABEL SCHEDULE(DWG E2 BELOW)FOR DETAILED LABEL INFO SYSTEM TIE- ( ) --EQUIPMENT AND WIRE/CONDUIT SCHEDULES FOLLOW(DWG E3&E4 BELOW) PRODUCTION METER DISCO MFG PROVIDED --RAPID SHUTDOWN IS INITIATED BY AC DISCONNECT OR INTEGRATED INVERTER SWITCH 60A,240VAC,2-POLE UL LISTED,75'C. FUSEDA0A MIN.RATING:40A METER TAP KIT MISC.NOTES AND SPECS: TAG 0 PV MODULE 1: (QUANTITY 16) STC:405;MPV:37.39;MPI:10.83;VOC:45.34;ISC:11.17 EXT. SOUTH SIDE OF HOUSE 1 PV MODULE 2: N/A 40 INVERTER (QUANTITY 1) 240V;6,000W;25.OA;10;UL 1741 CERTIFIED 41 INVERTER: N/A 99 --INVERTER(S)ARE 240VAC 10 OUTPUT --SYSTEM OUTPUT IS BALANCED 240VAC 10 ELECTRICAL ONE-LINE DIAGRAM CUST: SAFDAR ALI HAIDERI ELECT.UTILITY: XCEL ENERGY 1 L: REV 00 3735 Dunlap Street N SITE: 1133 FIRESIDE DR NE,FRIDLEY,MN,55432 PREMISE#: 302782050 EDIT:BF TruNorth Solar Arden Hills,MN 55112 SERVICE: 120/240V,10,3-WIRE,100A ACCOUNT#: 51-0012999968-9 11/6/2023 612-888-9599 PROJ: Solar By US METER#: 94892348 NOT FOR CONSTRUCTION UNLESS SIZE: 6.48KW DC 6KW AC APP ID#: LIQ Solar Rewards APPROVED BY MASTER ELECTRICIAN LABEL SCHEDULE ALL LABELS ARE DURABLE,PERMANENT AND NEC 690 COMPLIANT.EXTERIOR LABELS ARE WEATHERPROOF. ORANGE FILL COLOR INDICATES THE LABEL IS REQUIRED EXACT LABEL TEXT AND FORMAT MAY VARY IF MEANING IS CLEAR AND MEETS CODE REQUI9REMENTS. LT YELLOW: INDICATES THE LABEL NORMALLY APPLIED TO EQUIPT BY MFG COLOR SHOWN HERE INDICATES WHETHER LABEL APPLIES,NOT PHYSICAL LABEL COLOR. WHITE/NO COLOR: INDICATES THE LABEL DOES NOT APPLY(IGNORE) APPLY: MAIN METER APPLY: AC DISCO,PROD METER,COMBINER,AUX TRANSFORMER APPLY: PV SOURCE RACEWAYS,J-BOX COVERS,ETC. ill 906 MAIN(BIDIRECTIONAL)METER 497 WARNING: ELECTRIC SHOCK HAZARD-DO NOT 31 904 1 (SM) WARNING: PHOTOVOLTAIC POWER SOURCE TOUCH TERMINALS-LINE AND LOAD TERMINALS 905 1 (MED) WARNING: PHOTOVOLTAIC POWER SOURCE APPLY: MAIN METER,MAIN PANEL MAY BE ENERGIZED IN THE OPEN POSITION 910 (LG) I WARNING: PHOTOVOLTAIC POWER SOURCE 2 HT ROL WARNING: DUAL POWER SOURCES, SECOND SOURCE IS PV SYSTEM APPLY: METER COMBO,AC COMBINER,TAP CAN APPLY: INVERTER(DC DISCONNECT) 499 WARNING:TURN OFF PHOTOVOLTAIC AC DISCONNECT 999 INVERTER 1,INVERTER 2...ETC. APPLY: PRODUCTION METER PRIOR TO WORKING INSIDE PANEL 1 SOLAR DC DISCONNECT 1 909 SOLAR PRODUCTION METER AXIMUM DC VOLTAGE 480.0 V APPLY: PRODUCTION METER AC DISCO APPLY: UTILITY AC DISCONNECT 1 999 PRODUCTION METER DISCONNECT APPLY: INVERTER(DC DISCONNECT) 1 HT ROL RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 1 239 PHOTOVOLTAIC AC DISCONNECT E999 INVERTER 1 1 999 UTILITY PHOTOVOLTAIC MAIN AC DISCONNECT MAX AC OPERATING CURRENT: 25.0 A SOLAR DC DISCONNECT 1 239 PHOTOVOLTAIC AC DISCONNECT OPERATING AC VOLTAGE: 240 VAC 10 MAXIMUM DC VOLTAGE V MAX AC OPERATING CURRENT: 25.0 A OPERATING AC VOLTAGE: 240 VAC 10 APPLY: SOLAR AC COMBINER PANEL APPLY: (MISC.DC DISCONNECT) 1 HT ROL SOLAR PV SYSTEM EQUIPPED WARNING: SOLAR CIRCUITS ONLY 999 SOLAR DC DISCONNECT jllm WITH RAPID SHUTDOWN DO NOT ADD OTHER LOADS! SOLAR DC DISCONNECT MAXIMUM DC VOLTAGE V i pOwu wSMiEM 1..1 A- APPLY: EXT.MAIN METER SERVICE PANEL APPLY: SOLAR AC COMBINER PANEL 1 705 WARNING:THIS EQUIPMENT FED BY MULTIPLE SOURCES 999 SOLAR COMBINER PANEL TOTAL RATING OF ALL OVERCURRENT DEVICES 239 PHOTOVOLTAIC AC DISCONNECT APPLY: SOLAR&UTILITY SERVICE EQUIPMENT EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE MAX AC OPERATING CURRENT: 25.0 A 121 CUST. CAUTION:MULTIPLE SOURCES OF POWER SHALL NOT EXCEED AMPACITY OF BUSBAR OPERATING AC VOLTAGE: 240 VAC 10 (FIELD) INPUT CIRCUIT NAME OP.VOLTAGE. OP.CUR. TO BE CREATED:SITE SPECIFIC DIAGRAM SHOWING APPLY: EXT.SERVICE DISCONNECT 1 INV 1 VAC A LOCATIONS OF ASSOCIATED EQUIPMENT SUCH AS: MAIN METER 1 EMERGENCY DISCONNECT, 2 INV 2 240 VAC 47.5 A UTILITY SERVICE DISCO SERVICE DISCONNECT 3 INV 3 240 VAC 47.5 A SOLAR AC DISCO 4 VAC A PRODUCTION METER APPLY: ESS BATTERIES 5 VAC A INVERTERS,COMBINERS,LOCAL DISCOS AS NEEDED ENERGY STORAGE SYSTEM DISCONNECT 6 VAC A SOLAR PV ARRAYS MAXIMUM DC VOLTAGE:400V BATTERIES,STANDBY GENERATOR(AS NEEDED) INCLUDES ORIENTATION OF NORTH APPLY: SOLAR AC COMBINER PANEL APPLY: MISC. 999 SOLAR COMBINER PANEL nn UTILITY METER#2(CUST.SELL) 239 PHOTOVOLTAIC AC DISCONNECT APPLY: BACKFED BREAKER IN SERVICE PANEL MAX AC OPERATING CURRENT: A HT ROL WARNING: INVERTER OUTPUT CONNECTION APPLY: MISC. OPERATING AC VOLTAGE: VAC 10 DO NOT RELOCATE THIS OVERCURRENT DEVICE (FIELD) INPUT CIRCUIT NAME OP.VOLTAGE. OP.CUR. 1 VAC A APPLY: MISC. 2 VAC A APPLY: MAIN METER OR UTILITY SERVICE AREA 3 VAC A 1 TRUNORTH SOLAR 4 VAC A 612-888-9599 APPLY: MISC. 5 VAC A WWW.TRUNORTHSOLAR.COM 1 6 VAC A ELECTRICAL LABEL SCHEDULE CUST: SAFDAR ALI HAIDERI ELECTRIC UTILITI XCEL ENERGY E2: REV 00 3735 Dunlap Street N SITE: 1133 FIRESIDE DR NE, FRIDLEY, MN, 55432 PREMISE#: 302782050 EDIT: BF TruNorth Solar Arden Hills, MN 55112 SERVICE: 120/240V, 10, 3-WIRE, 100A ACCOUNT#: 51-0012999968-9 11/6/2023 612-888-9599 PROJ: Solar By US METER#: 94892348 NOT FOR CONSTRUCTION UNLESS SIZE: 6.48KW DC 6KW AC APP ID#: APPROVED BY MASTER ELECTRICIAN O EQUIPMENT SCHEDULE DC EQUIPMENT TAG QUANT DESCRIPTION OR ID MFG PART# SPECS NOTES 0 16 MODULE 1 Q-Cells Q.PEAK DUO BLK ML STC:405;MPV:37.39;MPI: 10.83;VOC:45.34;ISC: 1 2 10 16 DC-DC OPTIMIZER SOLAREDGE 5440 440W; 1 PV MODULE PER OPTIMIZER 11 13 1 IJBOX(SOLAR) SOLADECK/OTHER JNEMA3R AS NEEDED FOR WIRE TRANSITIONS,MAY NOT BE SHOWN 14 15 16 17 INVERTERS 40 1 INVERTER 1 SOLAREDGE SE6000H-US 240V; 6,000W;25.OA; 10; UL 1741 41 42 43 AC EQUIPMENT 46 1 INV.COMMUNICATIONS KIT SOLAREDGE 1 FOR WIRELESS OR HARDWIRE,1 EACH INVERTER IF CELLULAR 47 50 51 52 53 54 60 61 62 2 SPD-SURGE PROTECTIVE DEVICE DELTA OR SIMILAR LA302 TYPES 1&2 SOLAR SERVICE,UTILITY SERVICE 63 65 1 INTERNET ROUTER MONITORING DATA ACCESS TO INTERNET CUSTOMER OWNED 66 67 68 70 1 UTILITY AC DISCO SIEMENS OR SIM. 240VAC,60A,2-POLE,UNFUSED,NEMA3R,SVC RATED EXT.METER AREA 71 2 PRODUCTION METER DISCO FUSE 40A 250VAC 72 1 PRODUCTION METER DISCO SIEMENS OR SIM. 240VAC,60A,2-POLE,FUSED,NEMA3R,SVC RATED EXT.METER AREA 73 74 80 1 SERVICE PANEL SQUARE D 240VAC,100A,10 INTERIOR 81 82 84 1 PRODUCTION METER SOCKET MILBANK OR SIMILA U4801-XL-5T9 600V,200A,10,3-WIRE,BYPASS,NEMA3R EXT.METER AREA 85 1 PRODUCTION METER UTILITY OWNED ONE-WAY 240V,200A,10,3-WIRE 86 87 90 1 SYSTEM TIE-IN HARDWARE MILBANK K4977-EXT UL,300V,100A TAP CONNECTOR KIT MFG PROVIDED 91 92 93 1 MAIN METER SOCKET IMILBANK OR SIMILA U4801-XL-5T9 160OV,200A,10,3-WIRE,BYPASS,NEMA3R EXISTING MILBANK BYPASS 94 1 MAIN UTILITY METER JUTLITY OWNED JBIDIRECTIONAL 1240V,200A,10,3-WIRE 95 96 99 1 UTLITY TRANSFORMER JUTILITY OWNED 3735 Dunlap Street N ELECTRICAL EQUIPMENT SCHEDULE E3: REV 00 TruNorth Solar Arden Hills, MN 55112 Solar By US CUST: SAFDAR ALI HAIDERI EDIT: BF 612-888-9599 6.48KW DC 6KW AC SITE: 1133 FIRESIDE DR NE, FRIDLEY, MN, 55432 11/6/2023 ZL WIRE AND CONDUIT SCHEDULE DC CIRCUITS CIRCUIT MIN WIRE 1-WAY #WIRES CONDUIT MIN. TAG QUANT. DC CIRCUIT OR SEGMENT NAME WIRE TYPE S.IZE LEN. EACH TYPE CONDUIT NOTES (FT) CIRCUIT SIZE 0 16 PV MODULE 1 OUTPUT PV 12 AWG 4 2 (NOT SHOWN)PV MODULE LEADS 1 2 4 2 DC CONDUCTOR(FREE AIR) CU-PVWIRE 10 AWG 70 2 OPTIMIZER DC CIRCUITS TO JBOX 5 2 DC CONDUCTOR CU-THWN2 12 AWG 30 2 EMT 0.75" JBOX OUTPUT TO INVERTER 6 7 8 10 11 12 13 14 15 AC CIRCUITS CIRCUIT MIN WIRE 1-WAY #WIRES CONDUIT MIN. TAG QUANT. AC CIRCUIT OR SEGMENT NAME WIRE TYPE S.IZE LEN. EACH TYPE CONDUIT NOTES (FT) CIRCUIT SIZE 40 1 INVERTER OUTPUT CU-THWN2 8 AWG 6 2+N,G OUTPUT TO AC DISCO 41 42 50 51 52 53 68 70 71 1 UTILITY AC DISCO CU-THWN2 6 AWG 6 2+N,G EMT 0.75" TO PRODUCTION METER 72 1 PRODUCTION METER CU-THWN2 6 AWG 6 2+N,G EMT 0.75" TO PRODUCTION METER DISCO 73 1 PRODUCTION METER DISCO CU-THWN2 6 AWG 6 2+N,G EMT 0.75" TO SYSTEM TIE-IN POINT(TAG 90) 91 101 102 1 EGC CU 6 AWG 100 1 10 AWG ALLOWED WHERE PROTECTED 103 1 AUX.GROUNDING ELECTRODE&CONDUCTC CU AS NEEDED PER NEC 690.47,FOR DC: 250.166;FOR AC:TABLE 250.66 104 WIRE&CONDUIT SCHEDULE E4: REV 00 3735 Dunlap Street N EDIT: BF TruNorth Solar Arden Hills, MN 55112 Solar By US CUST: SAFDAR ALI HAIDERI 11/6/2023 612-888-9599 6.48KW DC 6KW AC SITE: 1133 FIRESIDE DR NE, FRIDLEY, MN, 55432 NOT FOR CONSTRUCTION UNLESS APPROVED BY MASTER ELECTRICIAN CONDUCTOR SIZING CALCULATIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 J z .-i N Ul ry K F w w F Q w z > d' a. U- z Ul Ul Q F O � F w Z Z d' W U d' F d' Z W w J .-i w U. N w °� Z w w W N .. Q O .~W. W d' F F O Z Q w F > K F Z W O Ul N .-i W J 0 F F W F (� U) Z U z F W F F > d' O Q O Q p] W Q z LL Ul C7 O' Ua w Q N Ow � w U � U Q 00 � � � ZUO � Uoj � Uoj in � g � QUz w � � F CIRCUIT OR SEGMENT NAME a J Q u o z LU w � a U O m w F Z I w Z w F z F w = O w of _LU OU � N O a OU QU 0 > w � Qw xk � O Q � 0UOQ 0of 0 � � � ��� zwF � z �ui U � Z Z F w F O D v D" w O J U U 4 2 DC CONDUCTOR(FREE AIR) CU-PVWIR 10 AWG 380 1 8.5 15 140 0.71 0 1 0.71 18.8 21.1 16 AWG TABLE 310.17(FREE AIR) 70 0.39% 5 2 DC CONDUCTOR 7U-THWN2 12 AWG 380 1 8.5 15 86 1 2 1 1 18.8 15 14 AWG TABLE 310.16 30 0.27% 6 40 1 INVERTER OUTPUT CU-THWN2 8 AWG 240 1 25 25 86 1 2 1 1 31.3 25 12 AWG TABLE 310.16 6 0.10% 41 42 50 51 68 70 71 1 UTILITY AC DISCO CU-THWN2 6 AWG 240 1 25 25 86 1 2 1 1 31.3 25 10 AWG TABLE 310.16 72 1 PRODUCTION METER CU-THWN2 6 AWG 240 1 25 25 86 1 2 1 1 31.3 25 10 AWG TABLE 310.16 73 1 PRODUCTION METER DISCO CU-THWN2 6 AWG 240 1 25 25 50 1.15 3 1 1.15 31.3 21.7 10 AWG NOTES FOR INDICATED COLUMN: 5 WIRE SIZE SPECIFIED IN ONE-LINE TYPICALLY INCLUDES CONSIDERATION FOR VOLTAGE DROP AND CONNECTION TERMINAL/LUG REQUIREMENTS 8 FOR DC OPTIMIZER STRING: (SUM OF PV WATTAGE)/(DC VOLTAGE REQUIRED BY INVERTER).FOR AC CIRCUITS,TYPICALLY INVERTER OUTPUT RATING 9 PV CIRCUITS=COLUMN 8*1.25.OPTIMIZER CIRCUITS= MAXIMUM CONTINUOUS OPTIMIZER OUTPUT RATING.INVERTER OUTPUT CIRCUIT= INVERTER CONTINUOUS RATING. 10 TEMPERATURE OF CONDUCTOR ENVIROMENT(FAHRENHEIT) 11 TEMPERATURE CORRECTION FACTOR FROM TABLE 310.15(B)(1) 12 QUANTITY OF CURRENT CARRYING CONDUCTORS IN THE CONDUIT 13 FROM TABLE 310.15(C)(1) 14 COMBINE ADJUSTMENTS AND CORRECTION FACTORS,COLUMN 11*COLUMN 13 15 TEST#1 =COLUMN 9*1.25--NEC 690.8(B)(1),MAXIMUM CIRCUIT CURRENT*1.25.THIS IS ALSO THE VALUE USED FOR OCP SIZING. 16 TEST#2=COLUMN 9/COLUMN 14--NEC 690.8(B)(2),MAX.CIRCUIT CURRENT WITH ADJUSTMENTS AND CORRECTION FACTORS 17 FROM TABLE 310.16 OR 310.17.LARGEST SIZE RESULTING FROM CALCULATIONS IN COLUMNS 15&16 18 NEC TABLE REFERENCED 19 ONE WAY LENGTH.NOTE THIS IS ONLY FOR THE SEGMENT SPECIFIED.ADDITIONAL SEGMENTS WILL ADD TO THE TOTAL VOLTAGE DROP OF A CIRCUIT. 20 VOLTAGE DROP PERCENTAGE USING THE OPERATING VOLTAGE AND NOMINAL CURRENT FOR THE SEGMENT CONDUCTOR SIZING CALCULATIONS E5: REV 00 3735 Dunlap Street N EDIT: BF TruNorth Solar Arden Hills, MN 55112 Solar By US CUST: SAFDAR ALI HAIDERI 11/6/2023 612-888-9599 6.48KW DC 6KW AC SITE: 1133 FIRESIDE DR NE, FRIDLEY, MN, 55432 NOT FOR CONSTRUCTION UNLESS APPROVED BY MASTER ELECTRICIAN