Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Isabel Pinguil Permit Pack 3411 flat
GENERAL NOTES AERIAL VIEW CODE AND STANDARDS a 1.ALL WORK SHALL COMPLY WITH 2O23 NATIONAL ELECTRIC CODE(NEC),2020 MINNESOTA BUILDING CODE,2020 r' L U E RAVE MINNESOTA RESIDENTIAL CODE(MRC),2018 INTERNATIONAL RESIDENTIAL CODE(IRC),2018 INTERNATIONAL , PLUMBING CODE(IPC),AND ALL STATE AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. — `` r ��'` 1403 N. Research Way SITE NOTES/OSHA REGULATION -V Orem, UT 84097 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. A ' 800.377.4480 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. WWW.BLUERAVENSOLAR.COM 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. ' CONFIDENTIAL-THE INFORMATION 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND •� , r< '""�•,4 THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT y r ,T i yy.., HEREIN CONTAINED SHALL NOT BE THE BUILDING OR STRUCTURE. USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR SOLAR CONTRACTOR IN PART TO OTHERS OUTSIDE 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. i RECIPIENTS ORGANIZATION,EXCEPT 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER IN CONNECTION WITH THE SALE AND THE MANUFACTURER'S INSTALLATION REQUIREMENTS. USE OF THE RESPECTIVE EQUIPMENT, 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF WITHOUT THE WRITTEN PERMISSION STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 1 OF BLUE RAVEN SOLAR LLC. 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO 1 LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A SUITABLE SEALING COMPOUND. 6.DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. ,- C E RT I F I E D 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. i 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT r PV INSTALLATION AVAILABLE. 9.ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC PROFESSIONAL PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND Scott Gurney CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND t #PV-011719-015866 LISTED FOR THE APPLICATION PER NEC 690A(B). f-' 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. CONTRACTOR: 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) BRS FIELD OPS IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. 800-377-4480 EQUIPMENT LOCATIONS ' t w i '• ! Sealed For 1.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT �' • ` j ' • ` WILL BE PROVIDED AS PER SECTION NEC110.26. '� ���f Existing Roof & 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS r► Attachment Only U SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). " N U 0 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC .. _ APPLICABLE CODES. �z � 4.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. F. f .�� . O LO ,i 7711 • ��_ , ``�fitlll,�� � Y M PROJECT INFORMATION: �. %�_ A CA�LF�'; w � 00 6 NUMBER OF STORIES: 2 ► 7CEN D .•• = z C: ~ _ LL O U N N CONDUIT RUN: Exterior � � - ECOBEE QTY: 0 i,' ENG E _ z Cl) cn LIGHT BULB QTY: 0 _ 52823 .:,`Q` IY '� O J 2 2 PV METER: Not Required DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX ,TF•••...,,,,,,..N�S°; �' } a ROOF TYPE (1) INFORMATION: OF �y{1N . o 0_ Q Q � in WIND SPEED: 115 mph CONSTRUCTION -V-B PV1 -COVER SHEET F_ � LU ROOF TYPE: Comp Shingle GROUND SNOW LOAD: 50 Ib/ft2 ZONING: RESIDENTIAL PV2-SITE PLAN in a 00 z FRAMING TYPE: Rafter WIND EXPOSURE FACTOR: C PV3- ROOF PLAN M CV — U U SHEATHING TYPE: NONE SEISMIC DESIGN CATEGORY: B PV4-STRUCTURAL U L U-) 2 Q IO ATTACHMENT: SFM Infinity Flashkit PV5- ELECTRICAL 3-LINE DIAGRAM RACKING: Unirac SFM Infinity @ 32" OC Portrait/48" OC Landscape 12/6/23 DRAWING BY: NUMBER OF ATTACHMENTS: 72 SCOPE OF WORK PV6- ELECTRICAL CALCULATIONS PV7-WARNING LABELS AND LOCATIONS Brendan Fillmore ROOF TYPE (2) INFORMATION (IF APPLICABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY PV8- PLACARD PLOT DATE: *SEEPV4.2 NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. (ALL OTHER SHEETS AS REQUIRED) Digitally signed SS- PRODUCT SPEC. SHEETS by John A. December 6, 2023 Calvert PROJECT NUMBER: SYSTEM TO BE INSTALLED INFORMATION: I hereby certify that this plan,specification or report w•asprepared bymeor UTILITY COMPANY: 905524 DC SYSTEM SIZE: 10.935 kW DC under direct supervision and that am duly Licensed Professional Xcel Energy MN Date: Engineerer under the lauds of the State of Minnesota.John A.Calvert,License No. 2•0 SHEET NAME 2023.1 6 : AC SYSTEM SIZE: 7.83 kW AC 52823 Expiration Date:30-June-2024 L L L MODULE TYPE: (27) Qcells Q.PEAK DUO ML-G10+405 PERMIT ISSUER: 11:20:35 -07'00' COVER SHEET INVERTER TYPE: Enphase IQ8PLUS-72-2-US MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 City of Fridley REVISION: PAGE NUMBER: 0 PV1 PV SYSTEM SPECIFICATIONS LEGEND TOTAL NUMBER OF MODULES: 27 JUNCTION BOX MODULE MAKE AND MODEL: Qcells Q.PEAK DUO ML-G10+405 MODULE WATTAGE: 405W DC UTILITY METER BLUE RAVEN INVERTER MAKE AND MODEL: Enphase IQ8PLUS-72-2-US 1403 N. Research Way INVERTER TYPE: Microinverter(1 Inverter per PV Module) FM MAIN SERVICE PANEL Orem, UT 84097 INVERTER CURRENT OUTPUT: 1.21A AC 800.377.4480 INVERTER NOMINAL VOLTAGE: 240V AC AC DISCONNECT WWW.BLUERAVENSOLAR.COM INVERTER WATTAGE: 290W AC \ CONFIDENTIAL-THE INFORMATION \ HEREIN CONTAINED SHALL NOT BE CB COMBINER BOX USED FOR THE BENEFIT OF ANYONE II \ EXCEPT BLUE RAVEN SOLAR NOR \ SHALL N PART TO OTOSED HERS(N WHOLE OUTS DE OR \ PROPERTY LINE LC LOAD CENTER RECIPIENTS ORGANIZATION,EXCEPT II \ IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, SUB SUBPANEL WITHOUT THE WRITTEN PERMISSION II \ OF BLUE RAVEN SOLAR LLC. \ PV METER rNABCEP\\ \ \ \ TS TRANSFER SWITCH CERTIFIED \ PV INSTALLATION / ESS SUNPOWER ESS PROFESSIONAL Scott Gurney /II SUNPOWER HUB+ #PV-011719-015866 / CONTRACTOR: 19 19 / RPO REMOTE POWER OFF BRS FIELD OPS FENCE 800-377-4480 19 19 m I w Lu I FIRE SETBACK II � � mina a I Ou) U II ® a 0 p / TRENCHING N U� >- .. > � ® ® ® ® ® ® ® p F / i PROPERTY LINE Q LO II [if co � M ❑ \ \ L SCALE: 3/64" = V-0" w ch � °' ° \ / U) N N_ II \\ Z w Lau ° Sealed For w '� 0 J 2 II WW = Existing Roof & 2 C: >- 0- H a a cn in II �5 U) o LL Attachment Only tea` w >_ >_ M MSP C CB I I VJ Z O zZ /A c4 I � H ` A. CA4 ��i� DRAWING BY: FENCE GATE z LO ° ���,�� ••• ��; Brendan Fillmore UTILITY PV AC DISCONNECT PROPERTY LINE I I iCEN •D XCEL PV AC DISCONNECT NOTES = I _ PLOT DATE: UTILITY PV AC DISCONNECT,WHERE REQUIRED,WILL BE INSTALLED WITHIN 10 FT - ENG E - (� OF UTILITY METER.AC DISCONNECT SHALL BE VISIBLE-OPEN TYPE,LOCKABLE, December I I 6, 2023 AND READILY ACCESSIBLE.A UTILITY-REQUIRED YELLOW WITH BLACK LETTERING •, 52823 :�Q- "PV AC DISCONNECT"PLACARD AT THE AC DISCONNECT SHALL BE INSTALLED. �•,_ .•coQ PROJECT NUMBER: 12/6/23 T •••.,_ _ ` IF THE AC DISCONNECT CANNOT BE LOCATED TOGETHER IN A READILY F I i t` ACCESSIBLE LOCATION WITHIN 10'OF THE MAIN SERVICE METER,A DIRECTORY I OF•MAN ��� 905524 PLACARD WILL BE INSTALLED ATTHE MAIN SERVICE METER CLEARLY SHOWING / , , THE LOCATION OF THE AC DISCONNECT. SHEET NAME: NO CLEARANCE ISSUES EXIST FOR OVERHEAD OR UNDERGROUND SERVICE LINES.A SITE PLAN UTILITY-REQUIRED YELLOW WITH BLACK LETTERING"PHOTOVOLTAIC SYSTEM peparherebedcbyertlmeorrthat under m this ydPectf supervision ication or aondtrt hatIam CONNECTED" PLACARD AT THE MAIN BILLING METER SHALL BE INSTALLED.24/7 Sateoflcensed Minnesota.JohnlA..aCalvelrteLicenser No.52823the laws fthe REVISION: PAGE NUMBER: UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL XCEL ENERGY EQUIPMENT Expiration Date:30-June-2024 0 PV2 PV SYSTEM SPECIFICATIONS LEGEND TOTAL NUMBER OF MODULES: 27 JUNCTION BOX MODULE MAKE AND MODEL: Qcells Q.PEAK DUO ML-G10+405 BLUE RAVEN MODULE WATTAGE: 405W DC UTILITY METER INVERTER MAKE AND MODEL: Enphase IQ8PLUS-72-2-US 1403 N. Research Way INVERTER TYPE: Microinverter(1 Inverter per PV Module) MSP MAIN SERVICE PANEL Orem, UT 84097 INVERTER CURRENT OUTPUT: 1.21A AC CHIMNEY 3' 800.377.4480 INVERTER NOMINAL VOLTAGE: 240V AC AC DISCONNECT WWW BLUERAVENSOLAR.COM INVERTER WATTAGE: 290W AC CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE CB COMBINER BOX USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR LOAD CENTER IN PART TO OTHERS OUTSIDE 1'-6" LC RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, 3 SUB SUBPANEL WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. 1'-6" PV PV METER 3, NABCEP TS TRANSFER SWITCH CERTIFIED PV INSTALLATION ® ® ® ® ESS SUNPOWER ESS PROFESSIONAL Scott Gurney #PV-011719-015866 MP1 � MP2 HUB SUNPOWER HUB+ CONTRACTOR: #OF MODULES: 15 0 ® #OF MODULES: 12 RPO REMOTE POWER OFF BRS FIELD OPS AZIMUTH: 268 AZIMUTH: 88 800-377-4480 PITCH: 18 TSRF: 72% PITCH: 18° FIRE SETBACK AREA: 652.86 ft.2 ® ® ® ® TSRF: 69 /0 O AREA: 455.12 ft.2 = U • • ILL TRENCHING N U O 31 T-6" z i Z >Q >Y 1'-6" O i PROPERTY LINE 0 > U) i H — CO CO co � Q SCALE: 3/32" = 1'-0" z Uj (D 00 o O ww � Z U � NN ❑ O� F5 Sealed For w 0 g Existing Roof & w C: } D- Attachment Only F- z >_ >_ oz � cn UU C ' \ A' A4. DRAWING BY: LMSP > > • Brendan Fillmore ICEN D XCEL PV AC DISCONNECT NOTES - - PLOT DATE: UTILITY PV AC DISCONNECT,WHERE REQUIRED,WILL BE INSTALLED WITHIN 10 FT ENG E OF UTILITY METER.AC DISCONNECT SHALL BE VISIBLE-OPEN TYPE,LOCKABLE, December 6 2023 AND READILY ACCESSIBLE.A UTILITY-REQUIRED YELLOW WITH BLACK LETTERING 52823 "PV AC DISCONNECT"PLACARD AT THE AC DISCONNECT SHALL BE INSTALLED. UTILITY PV AC DISCONNECT :���� IF THE AC DISCONNECT CANNOT BE LOCATED TOGETHER IN A READILY POINT OF INTERCONNECTION ' '���••.�•.... •.•`GjQ� PROJECT NUMBER: ACCESSIBLE LOCATION WITHIN 10'OF THE MAIN SERVICE METER,A DIRECTORY 12/6/23 �� OF •M1NN .` 905524 PLACARD WILL BE INSTALLED AT THE MAIN SERVICE METER CLEARLY SHOWING I THE LOCATION OF THE AC DISCONNECT. OVERHEAD SERVICE LINE �t I L �` SHEET NAME: NO CLEARANCE ISSUES EXIST FOR OVERHEAD OR UNDERGROUND SERVICE LINES.A ROOF PLAN UTILITY-REQUIRED YELLOW WITH BLACK LETTERING"PHOTOVOLTAIC SYSTEM herebycertifythatthisplan,specificationorrepspreparedbyme or under my direct supervision and that I am a dulyly Licensed ProfCONNECTED" PLACARD AT THE MAIN BILLING METER SHALL BE INSTALLED.24/7 Calvert,License No. underExpiration Date 30-June-State of 2024sota.John A. REVISION: PAGE NUMBER: Calvert,License No.52823 Expiration Date:30-June-2024 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL XCEL ENERGY EQUIPMENT 0 PV3 STRUCTURAL INFORMATION: STRUCTURAL NOTES: PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5" SPLICE ROOF TYPE (1): ROOF TYPE: Comp Shingle SHEATHING TYPE: NONE BLUE RAVEN FRAMING TYPE: Rafter None FRAMING SIZE: 2x8 @ 16"OC 1403 N. Research Way CEILING JOIST SIZE: None @None" OC 16" � 48" MAX. - Orem, UT 84097 ATTACHMENT: SFM Infinity Flashkit MAX. LANDSCAPE 800.377.4480 RACKING: Unirac SFM Infinity WWW.BLUERAVENSOLAR.COM @ 32" OC Portrait/48" OC Landscape PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5" SPLICE CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE NUMBER OF ATTACHMENTS: 72 USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR PV MODULE COUNT: 27 Modules SHALL IT BE DISCLOSED IN WHOLE OR N PART TO OTHERS OUTSIDE TOTAL ARRAY AREA: 550.8 ft2(20.4ft2/panel) RECIPIENTS ORGANIZATION,EXCEPT TOTAL ROOF AREA: 3041.16 ft2 N CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, ARRAY/ROOF AREA: 18.1% WITHOUT THE WRITTEN PERMISSION ARRAY WEIGHT: 1,350 Ibs(50 Ibs/panel) — 10 32" MAX. OF BLUE RAVEN SOLAR LLC. DISTRIBUTED LOAD: 2.45 Ibs/ft2 MAX. PORTRAIT POINT LOAD: 18.75 Ibs/attachment *NOTE:LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARY ATTACHMENT SPACING- FRONT VIEW -RACKING ATTACHMENTS TO BE STAGGERED rNACEP BASED ON FIELD CONDITIONS.MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PER li ENGINEER OF RECORD SPECIFICATIONS. SCALE: 3/4" = 1'-0" CERTIFIED UNIRAC SFM INFINITY UNIRAC SFM MICRORAIL/SPLICE A PV INSTALLATION PV MODULE PROFESSIONAL �- Scott Gurney QCELLS Q.PEAK DUO ML-G10+405 #PV-011719-015866 PV MODULE B PORTRAIT CONTRACTOR: UNIRAC SFM SLIDER BRS FIELD OPS _ ROOF STRUCTURE 800-377-4480 (E) ROOF MODULE- SHEATHING - WIDTH FLASHING �= A U (1) 5/16" STAINLESS STEEL LAG BOLT �� ���� B Q LANDSCAPE z WITH 2-1/2" MIN. EMBEDMENT f �- O cB LO AND FLAT WASHER 2 ' MIN. EMBED. �� 18° "- coMODULE Q � = W 00 IDTH z ti -� 0 W W MIDDLE/TOP STANDOFF DETAIL ATTACHMENT SPACING- SIDE VIEW Z N N A (E) BUILDING STRUCTURE D SCALE: 3" = T-0" SCALE: 1/2" = T-0" w 0 J 2 QCELLS Q.PEAK DUO ML-G10+405 2 } Q_ ~ ~ a a a cn cn PV MODULE H z >_ >_ Sealed For Cl) 00 z U U UNIRAC SFM TRIMRAIL Existing Roof & U L u) a FLASHING Attachment Only DRAWING BY: UNIRAC SFM SLIDER AND Brendan Fillmore TRIMRAIL ROOF ATTACHMENT (E) ROOF SHEATHING PLOT DATE: N. cq<t%'; December 6, 2023 (1) 5/16" STAINLESS STEEL LAG BOLT �� ��� _ ��� �� ••• iCEN D -•• PROJECT NUMBER: WITH 2-1/2" MIN. EMBEDMENT = _ AND FLAT WASHER 2%' MIN. EMBED. - ENG �E - 905524 12/6/23 52823 -.OQ: SHEET NAME: TF•• STRUCTURAL I hereby certify that this plan,specification or report was prepared by me or t OF•MI \� BOTTOM STANDOFF DETAIL under my direct supervision and that I am a duly Licensed Professional /fill I��� REVISION PAGE NUMBER p Engineer under the laws of the State of Minnesota.John A.Calvert,License No. o SCALE: 3"= 1'-0" (E) BUILDING STRUCTURE 52823 Expiration Date:30-June-2024 0 PV4 (1) 8 AWGTHHN/THWN-2,CU.,BLACK(L1) 32.7 A AC (3) 10 AWGTHHN/THWN-2,CU.,BLACK(LI) MAX 10.9 A A (1) 10 AWGTHHN/THWN-2,CU.,BLACK(LI) MAX 10.9 AA (1) 12-2TC-ER,THHN/THWN-2,CU. MAX 10.9 A AC 15 (1) 8 AWG THHN/THWN-2,CU.,RED(1-2) 240 V AC 3 (3) 10 AWG THHN/THWN-2,CU.,RED(L 2) 240 V A 2 (1) 10 AWG THHN/THWN-2,CU.,RED(1-2) 240 V A 1 (1) 6 AWG BARE,CU(EGC) 240 V AC (1) 8 AWGTHHN/THWN-2,CU.,WHITE(N) (1) 10 AWGTHHN/THWN-2,CU.,GREEN(EGC) (1) 10 AWGTHHN/THWN-2,CU.,GREEN(EGC) (1) 10 AWG THHN/THWN-2,CU.,GREEN(EGC) OR 10-2 OF-B W/G(OR NM-B),THHN/THWN-2,SOLID CU. (1) 3/4 INCH EMT EXTERIOR (1) 3/4 INCH EMT EXTERIOR (1) 3/4 INCH EMT(Not Required for OF-B or NM-B Cable) EXTERIOR EXTERIOR BLUE RAVEN XCEL PV AC DISCONNECT NOTES UTILITY PV AC DISCONNECT,WHERE REQUIRED,WILL BE INSTALLED WITHIN 10 FT OF UTILITY METER.AC DISCONNECT SHALL BE VISIBLE-OPEN TYPE,LOCKABLE, AND READILY ACCESSIBLE.A UTILITY-REQUIRED YELLOW WITH BLACK LETTERING 1403 N. Research Way "PV AC DISCONNECT"PLACARD AT THE AC DISCONNECT SHALL BE INSTALLED. Orem, UT 84097 IF THE AC DISCONNECT CANNOT BE LOCATED TOGETHER IN A READILY 800.377.4480 ACCESSIBLE LOCATION WITHIN 10'OF THE MAIN SERVICE METER,A DIRECTORY WWW.BLUERAVENSOLAR.COM PLACARD WILL BE INSTALLED AT THE MAIN SERVICE METER CLEARLY SHOWING THE LOCATION OF THE AC DISCONNECT. DESIGNER NOTES: ELECTRICAL NOTES: CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE INTERCONNECT USING A LOAD SIDE TAP IN MSP,EXTERIOR POI. 27 INVERTERS X 290 W AC=7.83 KW AC SINGLE PHASE 240V PV SYSTEM. USED FOR THE BENEFIT OF ANYONE 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL XCEL ENERGY EQUIPMENT. EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR (27) QCeIIS Q.PEAK DUO ML-G10+ 405 IN PART TO OTHERS OUTSIDE UL 1703 COMPLIANT RECIPIENTS ORGANIZATION,EXCEPT ENPHASE IQ COMBINER 4 (27) Enphase IQ8PLUS-72-2-US IN CONNECTION WITH THE SALE AND 1 PHASE (E)200A MAIN SERVICE PANEL LOAD SIDE TAP X-IQ-AM1-240-4 USE OF THE RESPECTIVE EQUIPMENT, 3-WIRE (E)200A/2P MAIN BREAKER (SOLAR LOAD ONLY) 1 PHASE,UL 1741 COMPLIANT WITHOUT THE WRITTEN PERMISSION 4" 'W"PVC JB-1 EZ SOLAR OF BLUE RAVEN SOLAR LLC. UTILITY PV AC DISCONNECT JUNCTION BOX JUNCTION BOX (E)200A/2P FUSED,AIC 10kA (N)20A/2P LOCKABLE,VISIBLE OPEN L, JB L, JB-1 L1 - (1) CIRCUIT OF 60A,240V,2-POLE L2 L2 L2___EGC EGC 9 MODULES NABCEP ENVOY r 15A/2P i CERTIFIED 45A I 2 1 FUSES N I PV INSTALLATION L1 L, (N)20A/2P L i L, JB-1 L, (1) CIRCUIT OF PROFESSIONAL N Lz L2 L2 Lz - - Scott Gurney N N EGC EGo 9 MODULES EGc -----EGc— ------ f----- — — #PV-011719-015866 1 G I 120/240VAC I LOAD SIDE TAP 1 2 1 CONTRACTOR: 60HZ 15 15 NEC 250.24(A)(5) j BRS FIELD OPS 1 PHASE (E)200A SUBPANEL DO NOT BOND j (N)20A/2P 1 JB-1 (1) CIRCUIT OF 800-377-4480 TO UTILITY I GROUNDS AND 1 L1 I L, L, GRID I (E)200A/2P I Lz Lz Lz - - L1 NEUTRALS I r___ EGc 4---EGC }___EGo �_ = 9 MODULES C L2 N 1 I N (E)LOADS 1 I 0 r EGC L--J 3 2 1 N .. 04 (E)LOADS RPA LOCATION. TEST AT THE LUGS ON 0 Y U) THE BOTTOM OF THE BUS BAR IN Y 1 THE PV COMBINER BOX. Q °cn 00 °� I G N O W � ti r-----------, z I I CC� (E)GROUNDING (N)%"COPPER GROUND ROD, LL G N N ELECTRODE(S) - 8'LONG,MIN.U FROM(E) r L Z GROUNDING CONDUCTOR. IF REQUIRED,VERIFICATION WILL BE DONE TO �� J ENSURE THE GROUNDING ELECTRODE SYSTEM IS GEC INSTALLED PER NEC LUJ O W LU CONGRUENT WITH CURRENT REQUIREMENTS.(NEC 250.64:6 OR 4 AWG SOLID ¢¢ a 250 PART III)IF NOT,ANEW GROUND ROD WILL BE COPPER GEC. • i G oaaa nn INSTALLED. �� I-- L.J INTERCONNECTION NOTES I F t z 705.12(B)(1)WHERE THE POWER SOURCE OUTPUT CONNECTION IS 00 z U U MADE TO A FEEDER, THE FEEDER SHALL HAVE AN AMPACITY GREATER _ _ =) cn � THAN OR EQUAL TO 125 PERCENT OF THE POWER-SOURCE OUTPUT ` CIRCUIT CURRENT. WHERE THE POWER-SOURCE OUTPUT CONNECTION DRAWING BY: IS MADE TO A FEEDER AT A LOCATION OTHER THAN THE OPPOSITE END OF THE FEEDER FROM THE PRIMARY SOURCE OVERCURRENT DEVICE, -' Brendan Fillmore THAT PORTION OF THE FEEDER ON THE LOAD SIDE OF THE POWER y PLOT DATE: SOURCE OUTPUT CONNECTION SHALL BE PROTECTED BY ONE OF THE FOLLOWING: (B)AN OVER CURRENT DEVICE AT THE LOAD SIDE OF THE December 6, 2023 POWER SOURCE CONNECTION POINT SHALL BE RATED NOT GREATER PROJECT NUMBER: THAN THE AMPACITY OF THE FEEDER. - 905524 705.12(B)(2)WHERE POWER SOURCE OUTPUT CONNECTIONS ARE MADE AT FEEDERS, ALL TAPS SHALL BE SIZED BASED ON THE SUM OF 125 SHEET NAME: PERCENT OF ALL POWER SOURCE(S) OUTPUT CIRCUIT CURRENT(S)AND ELECTRICAL THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE FEEDER CONDUCTORS FOR SIZING TAP CONDUCTORS USING THE REVISION: PAGE NUMBER: CALCULATIONS IN 240.21(B). UTILITY COMPANY: Xcel Energy MN PERMIT ISSUER: City of Fridley 0 PV5 MODULE SPECIFICATIONS Qce I Is Q.PEAK DUO ML-G10+405 DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS RATED POWER(STC) 405 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG. HIGH TEMP MICROINVERTERTO MAX.SHORT CIRCUIT CURRRENT(ISC)= 10.9 AAC MODULE VOC 45.13 V DC STATE Minnesota JUNCTION BOX(1) MAX.CURRENT(ISC X1.25)= 13.6 AAC MODULE VMP 37.85 V DC CITY MINNEAPOLIS CONDUCTOR(TC-ER,COPPER(90°C))= 12 AWG BLUE RAVEN MODULE IMP 10.7 A DC WEATHER STATION MINNEAPOLIS/BLAINE CONDUCTOR RATING= 30 A MODULE ISC 11.19 A DC ASHRAE EXTREME LOW TEMP(°C) -26 AMB.TEMP.AMP.CORRECTION= 0.96 VOC CORRECTION -0.27%/°C ASHRAE 2%AVG. HIGH TEMP(°C) 32 ADJUSTED AMP.= 28.8 > 13.6 1403 N. Research Way VMP CORRECTION -0.34%/°C JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 10.9AAC Orem, UT84097 7.4480 SERIES FUSE RATING 20ADC SYSTEM ELECTRICAL SPECIFICATIONS CIR1 CIR2 CIR3 CIR4 CIR5 CIR6 JUNCTION BOX(2) MAX.CURRENT(ISC X1.25)= 13.6AAC a W W W.BLUERAVRAVENSOSOLAR.COM ADJ. MODULE VOC @ ASHRAE LOW TEMP 51.3 V DC NUMBER OF MODULES PER MPPT 9 9 9 CONDUCTOR(THWN-2,COPPER(75°CTERM.))= 10 AWG CONFIDENTIAL-THE INFORMATION ADJ. MODULE V MP @ ASHRAE 2%AVG. HIGH TEMP 32.8 V DC DC POWER RATI NG PER Cl RCUIT(STC) 3645 3645 3645 CONDUCTOR RATING= 35 A HEREIN CONTAINED SHALL NOT BE TOTAL MODULE NUMBER 27 CONDUIT FILL DERATE= 1 USED FOR THE BENEFIT O A EXCEPT BLUE RAVEN SOLAR NOAR NORR MICROINVERTER SPECIFICATIONS Enphase IQ8+Microinverters STC RATING OF ARRAY 10935 AMB.TEMP.AMP.CORRECTION= 0.76 SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE POWER POINTTRACKING(MPPT) MIN/MAX 30 - 58 VDC ACCURRENT@ MAX POWER POINT(IMP 10.9 10.9 10.9 ADJUSTED AMP.= 26.6 > 13.6 RECIPIENTS ORGANIZATION,EXCEPT MAXI MUM I N PUT VOLTAGE 60VDC MAX.CURRENT(IMP X 1.25) 13.6125 13.6125 13.6125 JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 10.9AAC I N CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CI RCUIT 20 20 20 COMBINER BOX(3) MAX.CURRENT(ISC X1.25)= 13.6 A AC WITHOUT THE WRITTEN PERMISSION MAXI MUM USABLE DC INPUT POWER 440 W MAX.COMB.ARRAY AC CURRENT(I MP) 32.7 CONDUCTOR(THWN-2,COPPER(75°CTERM.))= 10 AWG OF BLUE RAVEN SOLAR LLC. MAXI MUM OUTPUT CURRENT 1.21 A AC MAX.ARRAY AC POWER 7830W AC CONDUCTOR RATING= 35 A AC OVERCURRENT PROTECTION 20A CONDUIT FILL DERATE= 0.8 NABCEP MAXI MUM OUTPUT POWER 290 W AC VOLTAGE RISE CALCULATIONS DIST(FT) COND. VRISE(V) VEND(V) %VRISE AMB.TEMP.AMP.CORRECTION= 0.96 CERTIFIED CEC WEIGHTED EFFICIENCY 97 % VRISE SEC. 1(MICRO TOJBOX) 32.4 12 Cu. 1.18 241.18 0.49% ADJUSTED AMP.= 26.88 > 13.6 VRISESEC.2(JBOXT0 COMBINER BOX) 65 10 Cu. 1.80 241.80 0.75% COMBINER BOX TO INVERTER RATED AMPS= 32.7AAC PV INSTALLATION AC PHOTOVOLATIC MODULE MARKING(NEC 690.52) VRISESEC.3(COMBINER BOX TO POI) 5 8Cu. 0.26 240.26 0.11% MAIN PV OCPD(15) MAX.CURRENT(RATED AMPS X1.25)= 40.84 AAC PROFESSIONAL NOMINAL OPERATING AC VOLTAGE 240 V AC TOTAL VRISE 3.23 243.23 1.35% CONDUCTOR(THWN-2,COPPER(75°CTERM.))= 8 AWG Scott Gurney #PV-011719-015866 NOMINAL OPERATING AC FREQUENCY 47-68 HZ AC CONDUCTOR RATING= 50 A MAXI MUM AC POWER 240VAAC P HOTOVOLTAIC AC DI SCON N ECT OUTP LIT LABEL(N EC 690.54) CONDUIT FILL DERATE= 1 CONTRACTOR: MAXIMUM AC CURRENT 1.0 A AC AC OUTPUT CURRENT 32.7 A AC AMB.TEMP.AMP.CORRECTION= 0.96 BRS FIELD OPS MAXIMUM OCPD RATING FOR AC MODULE 20 A AC NOMINAL AC VOLTAGE 240 V AC ADJUSTED AMP.= 48 > 40.8 800-377-4480 U 04 U >�> GROUNDING NOTES WIRING & CONDUIT NOTES Z LO Q Y LO 1.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690.47]AND[NEC 250.50-60]SHALL BE 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE O M PROVIDED. PER [NEC 690.47], THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BE APPLICATIONS. 4- M USED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR(USE Q N co CA INADEQUATE, OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE POLARIS BLOCK OR NEUTRAL BAR). CC USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 3.ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS DISALLOWED ABOVE G LLI Q) l'- 2.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN LIVE PARTS,MEYERS HUBS RECOMMENDED z THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER) IF SMALLER THAN#6 AWG COPPER WIRE 4. UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF Q C� W W PER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SURFACE IN ACCORDANCE WITH[NEC 11 0.2,1 10.3(A-B)]. LL C N N SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER[NEC 250.64(C)]. 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH WITH ROOF SURFACE TO BE USED FOR WIRE Z 3.GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN 8 AWG AND NO GREATER THAN 6 AWG MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2, AND SINGLE-CONDUCTOR CABLE LISTED AND - O J C 4.PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 250.122],AND ALL METAL IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT.ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS W 5 J O W W PARTS OR MODULE FRAMES ACCORDING TO[NEC 690.46]. REQUIRED. a 5.MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC 690.42]. 7.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 690.8]FOR MULTIPLE C c � >- 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A CONDUCTORS. o a Q Q MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 8.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/81,ABOVE LJJ 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (13)(2)(A)], [NEC TABLE N Z (n (n MANUFACTURER'S INSTALLATION INSTRUCTIONS. 310.15(13)(3)(A)],&[NEC 310.15(B)(3)(C)]. 00 z 8.ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED,WET AND UV RESISTANT,AND UL = CV C-C U U GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP U N Lo G Q 9.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVISES EDGES. EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, 10.GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED,AND BARE WHEN WET AND UV RESISTANT,RATED FOR 600V DRAWING BY: EXPOSED. 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE A MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. Brendan FIIImOre MINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TO 12.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION DAMAGE). 13.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS PLOT DATE: 12.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR CODED GREEN(OR MARKED 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC CONDUIT BETWEEN GREEN IF 4 AWG OR POSITIVE- M GREY) THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE 5..POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED 3.AL December 6, 2023 GROUNDED BUSHINGS AT BOTH ENDS. DC POSITIVE-GREY(OR MARKED GREY),DC NEGATIVE-BLACK(OR MARKED BLACK) 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZED 16.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE A OR L1-BLACK, PHASE B OR L2-RED, PROJECT NUMBER: ACCORDING TO[NEC 250.166],MINIMUM 8 AWG WHEN INSULATED,6 AWG WHEN EXPOSED TO DAMAGE. PHASE C OR L3-BLUE,NEUTRAL-WHITE/GRAY 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE 905524 CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH[NEC 250.134]OR[NEC 250.136(A)] USE-2 IS AVAILABLE AS UV WHITE REGARDLESS OF VOLTAGE. 17.RIGID CONDUIT,IF INSTALLED,(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, SHEET NAME: FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTING /� /�/� /� MEANS SHALL COMPLY WITH[NEC 690.13]AND[NEC 690.15]. E LEC C"LC S 19.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE COMPLYING WITH[NEC 230.6(4)]AND SECURED NO GREATER THAN 6'APART PER[NEC 330.30(B)]. REVISION: PAGE NUMBER: 0 PV6 *4 STANDARD LABELS ADDITIONAL LABELS WARNING LABEL BLUE RAVED FOR PV SYSTEM DISCONNECTING MEANS WHERE THE PHOTOVOLTAIC LABEL U2 LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE ELECTRIC SHOCK HAZARD OPEN POSITION. PLACARD TO BE YELLOW WITH BLACK LETTERING 1403 N. Research Way [2017 NEC 690.13(B)] SYSTEM CONNECTED AND TO BE PLACED ATUTLITYMETER. Orem, UT 84097 TERMINALS ON THE LINE AND [2020 NEC 690.13(B)] 800.377.4480 LOAD SIDES MAY BE ENERGIZED W W W.BLUERAVENSOLAR.COM IN THE OPEN POSITION CONFIDENTIAL-THE INFORMATION LABEL U3 HEREIN CONTAINED SHALL NOT BE LABEL 2 PV AC DISCONNECT I USED FOR THE BENEFIT OF ANYONE AND TO BE PLACED AT UTILITY PV AC DISCONNECT. EXCEPT BLUE RAVEN SOLAR NOR PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR THE DISCONNECTING MEANS AS A POWER SOURCE IN PART TO OTHERS OUTSIDE I AC DISCONNECT AND WITH THE RATED AC OUTPUT CURRENT AND THE RECIPIENTS ORGANIZATION,EXCEPT NOMINAL OPERATING AC VOLTAGE. IN CONNECTION WITH THE SALE AND (2017 NEC 690.541 USE OF THE RESPECTIVE EQUIPMENT, RATED AC OUTPUT CURRENT 32.67 A [2020 NEC 690.541 WITHOUT THE WRITTEN PERMISSION NOMINAL OPERATING AC VOLTAGE 240 V OF BLUE RAVEN SOLAR LLC. LABEL 3 NABCEP IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL CERTIFIED ANYWHERE THAT IS POWERED BY BOTH THE UTILITY DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL AND SUBPANELS. PV INSTALLATION [2017 NEC 705.12(B)(3)] LABEL 11 PROFESSIONAL SOURCES: UTILITY GRID AND (2020 NEC 705.12(B)(3)] I WARNINGA PERMANENT PLAQUE OR DIRECTORY TO BE PV SOLAR ELECTRIC SYSTEM LOCATED AT AC COMBINER PANEL. Scott Gurney PHOTOVOLTAIC SYSTEM [2017 NEC 110.21(B)] #PV-011719-015866 COMBINER PANEL [2020 NEC 110.21(B)] CONTRACTOR: OIWARNING LABEL4 DO NOT ADD LOADS B80 FIELD OPS APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE POWER 800-377-4480 POWER SOURCE OUTPUT CONNECTION SOURCE. DO NOT RELOCATE [2017 NEC 705.12(B)(2)(3)(b)] (2020 NEC 705.12(B)(3)(2)] THIS OVERCURRENT U DEVICE CVO UQ o Lo Lo � Y YLo SOLAR PV SYSTEM EQUIPPED LABEL 6 1— 0 M BUILDINGS WITH PV SYSTEMS SHALL HAVE A Q WITH RAPID SHUTDOWN PERMANENT LABEL LOCATED AT EACH SERVICE TOTH E NM EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS a/ z SWITCH TO THE TURN RAPID ARE CONNECTED OR AT AN APPROVED READILY CC "OFF"POSITION TO VISIBLE LOCATION AND SHALL INDICATE THE LOCATION 0 W I1J AQ� ~ G N N SHUT DOWN PV SYSTEM OF RAPID SHUTDOWN INITIATION DEVICES. PVLL SAND REDUCE SU BPAN EL HOCK HAZARD (2017 NEC 690.56(C)(1)(a)] UTILITY MAIN IF INTERCONNECTION AC METER PV COMBINER Z IN THE ARRAY (2020 NEC 690.56(C)] ( — METER SERVICE PANEL IS MADE HERE) DISCONNECT (IF APPLICABLE) BOX W '� O W W RAPID SHUTDOWN LABEL 7 O O O O 11 O a Q Q >_ fn SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT � w SWITCH FOR SWITCH U2 z (n (n • . (2017 NEC 690.56(C)(3)] 7 U3 = 00 Z U U PV SYSTEM (2020 NEC 690.56(C)(2)] U N LLo C Q O IF BREAKER0 O G IS USED 0 DRAWING BY: OBrendan Fillmore 3 PLOT DATE: December 6, 2023 PROJECT NUMBER: PLACARD 905524 LABELING NOTES SHEET NAME: 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT LABELS REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE 0 PV7 HANDWRITTEN[NEC 110.21] DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. BLUE RAVED CAUT ON 1403 N. Research Way Orem, UT 84097 MULTIPLE SOURCES OF POWER 8 W W W.BLUERAVRAVENSOSOLAR.COM DOWER TO THIS BUHEDM IS ALSO SUPPLIED FROM THE CONFIDENTIAL-THE INFORMATION HEREIN SHALLBE _OWING SOURCES WITH DISCONNECTS LOCATED AS SHMA/V USED FOROTHEABENDEFITOFANOYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND ROOFTOP PV ARRAY USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP w CERTIFIED a a . p PV INSTALLATION = PROFESSIONAL m a m a LL_O Scott Gurney #PV-011719-015866 H— CONTRACTOR: fl� BRS FIELD OPS L` 800-377-4480 U 0 UTILITY METER PV AC DISCONNECT SWITCH Z Q MAIN SERVICE DISCONNECT O F_ Y M Q c°n � °� 5284 TAYLOR ST NE, W N ti MINNEAPOUS MINNESOTA 55421 z �_ Lij OUL U � NN Z L Fn F5 W � -j 0 W W 2 >— D- cl) in H H a� ~ z cn cn � °N° Z UU U C/' Ln2 Q0 DRAWING BY: Brendan Fillmore PLOT DATE: DIRECTORY PLACARD NOTES December 6, 2023 PROJECT NUMBER: [NEC 705. 10]A PERMANENT PLAQUE OR DIRECTORY DENOTING THE 905524 LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT SHEET NAME LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR PLACARD ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING REVISION PAGE NUMBER INTERCONNECTED. THE MARKING SHALL COMPLY WITH [110.21(B)]. 0 PV8 Nor- OPEAK DUO ML-G10+ O PEAK DUO ML-G10+ SERIES BLUE RAVEN SOLAI ■Mechanical Specification SERIES a.169mm) QCp � Format 74.Oin x 41.1 in x 1.26in(including frame) C].6 oesamm) 15. o9samm) ��rr (1879 mm x 1045 mm x 32 mm) Weight 48.5lbs(22.Okg) 1 ~6I Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass 4.G, rg W°o.,e wsmm) F,em z 49]'ll]50 mm) 395-415 W 1132 Cel is with anti-reflection technology 9'1996mm) p Back Cover Composite film _ av 1pafi mm) 211% Maximum Module Efficiency Frame Black anodised aluminium Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Lebe1� �49�,nz�mm) Junction box 2.09-3.98 in x 1.26-2.36 in x 0.59-0.71 in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes e.o,e�eroie: i °min sio¢loeTarn) _ Cable 4mm2 Solar cable;(+)>49.2in(1250mm),(-)>_49.2in(1250mm) 9 +��L16'13]mml Lp O.6T Obmm) Connector Staubli MC4;IP68 °EA1 I-i MODEL O.PEAK DUO ML-G10+ aw°(24amm)-L- of r(samm) ■Electrical Characteristics POWER CLASS 400 405 410 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC(POWER TOLERANCE+5W/-OW) I Power at MPP' PM„ [W] 395 400 405 410 415 n Breaking the 21%efficiency barrier E Short Circuit Current' I5C [A] 11.13 11.16 11J9 11.22 11.26 Q.ANTUM DUO Z technology with zero gap cell layout E Open Circuit Voltage' Von IV] 45.03 45.06 45.09 45J3 45.16 boosts module efficiency up to 21.1 . Current at MPP I- [A] 10.58 10.64 10.70 10.76 10.82 Voltage at MPP VM„ [V] 37.32 37.59 37.85 38J1 38.37 Efficiency' r) I%] >-20J >-20.4 >-20.6 >-20.9 >-21.1 /25 A reliable investment 1�. MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Inclusive 25-year product warranty and 25-year linear Warranty performance warranty'. Power at MPP PM„ [W] 296.4 300A 303.9 307.6 311.4 " °" E Short Circuit Current I5C [A] 8.97 8.99 9.02 9.04 9.07 E Open Circuit Voltage Von IV] 42.46 42.49 42.52 42.56 42.59 .9 O Enduring high performance 2 Current at MPP I- [A] 8.33 8.38 8.43 8.48 8.53 Voltage at MPP VM„ IV] 35.59 35.82 36.04 36.27 36.49 Long-term yield security with Anti LeTID Technology, 'Measurement tolerances PM„±396;ISM;V°c±5%at STC:1000W/m2,25±2°C.AM 1.5 according to IEC 60904-3•2800 W/m2,NMOT,spectrum AM 1.5 ocelyls Anti PID Technology2 and Hot-Spot Protect. Ocells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE f�{( Extreme weather rating a gAi OS%deaste$adat.T oral error 9sBurin first ear.Thereafter max. High-tech aluminium alloy frame,certified for least 93.5%of nominal power0 9 P Y high snow(5400 Pa)and wind loads(4000 Pa). upto 10years.At least 86%of zonominal power up to 25 years.z 36 90 _____�_____i_____o __ All data within measurement w w tolerances.Full warranties in Innovative all-weather technology >a accordance with the warranty Q / 1 5 terms of the Ocells sales sm 00 _j �! Optimal yields,whatever the weather with excellent low-light $ so as 1. 15 30 35 organisation ofyour respective 40o sea wo Itee and temperature behaviour. YEARS country. IRRADIANCE[W/mj ¢ `Standard terms of guarantee for the 5 PV companies with the Typical module performance under low irradiance conditions in highest production capacity in 2021(February 2021) comparison to STC Conditions(25'C.1000 W/m). of The most thorough testing TEMPERATURE COEFFICIENTS ' programme in the industry Temperature Coefficient of lac a [%/K] +0.04 Temperature Coefficient of Va (i [%/K] -0.27 Qcells is the first solar module manufacturer to pass the Temperature Coefficient of P_ y [%/K] -0.34 Nominal Module Operating Temperature NMOT rF] +3 4 0 most comprehensive quality programme in the industry:The (43±3°C) new"Quality Controlled PW of the independent certification ■Properties for System Design o --- ---- institute TUV Rheinland. --- - Maximum System Voltage Vsrs IV] 1000(IEC)/1000(UL) PV module classification Class II a Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 0 'See data sheet on rear forfurther information. Max.Design Load,Push/Pull3 [Ibs/ft2] 75(3600 Pa)/55(2660 Pa) Permitted Module Temperature -40°F up to+185°F =APT test conditions according tolEC/TS62804-1:2015,method A(-150ov,96h) Max.Test Load,Push/Pull3 [Ibs/ft2] 113(5400 Pa)/84(4000 Pa) on Continuous Duty (-400Cupto+850C) 3 See Installation Manual ■Qualifications and Certificates = UL 61730,CE-compliant, Quality Controlled PV-TUV Rheinland, 2 IEC 61215:t No.NEC 3,215:solar /1 m U.S.Patent No.9,893,215(solar cells), S�® Cl41,dd US - m-s-0 1°++" 011 DRAWING TITLE: The ideal solution for: °•^ ° °°+ N 2U22f SPEC SHEET Rooftop arrays onH/ z® IDFIOI residential buildings DRAWING NUMBER: Ocells pursues minimizing paper output in consideration of the global environment. Sis N°te:InsmIIh lonlnstrUctlons must be followed.Contact our technical service for further information on approved installation of this product. Qee��s Hanwha Q CELLS America Inc.400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL hqc inquiry@gcells.com I WEB www.gcolls.com GLUE RAVED soi ENPHASE. IQ8 and IQ8+ Microinverters 1403N Research Way Orem,UT 84097 INPUT DATA i 800.377.4480 Commonly used module pairings' w 235-350 235-440 WWW.BLUERAVENSOLAR.COM Module compatibility 60-cell/120half-cell 60-cell/120 half-cell,66-cell/132 half-cell and72-cell/144 CONFIDENTIAL-THE INFORMATION half-cell HEREIN CONTAINED SHALL NOT BE MPPT voltage range v 27-37 29-45 USED FOR THE BENEFIT OF ANYONE G PT BLUE RAVEN SOLAR NOR Operating range v 25-48 25-58 SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE Min/max start voltage v 30/48 30/58 RECIPIENTS ORGANIZATION,EXCEPT } IN CONNECTION WITH THE SALE AND Max input DC voltage v 50 60 USE OF THE RESPECTIVE EQUIPMENT, Max DC current'[module lsc] A 15 WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. 0 Overvoltage class DC port II 0 DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit NAB C E P r CERTIFIED Peak output power VA 245 300 PV INSTALLATION Max continuous output power VA 240 290 PROFESSIONAL Nominal(L-L)voltage/range' V 240/211-264 Scott Gurney Max continuous output current A 1.0 1.21 #PV-011719-015866 1 Q 8 and I Q 8+ Microinverters Nominal frequency Hz 60 CONTRACTOR: Easy to install Extended frequency range Hz 50-68 BRS FIELD OPS Our newest I08 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with AC short circuit fault current over 2 385-498-6700 defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors 3 cycles Aims power to AC power efficiently.The brain of the semiconductor-based microinverter Power Line Communication Max units per 20 A(L-L)branch circuit4 16 13 is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components Total harmonic distortion <5% microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple Overvoltage class AC port III to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling AC port backfeed current mA 30 energy systems. Power factor setting 1.0 High productivity and reliability Grid-tied power factor(adjustable) 0.85leading-0.85lagging Produce power even when the Peak efficiency % 97.5 97.6 .� a Enphasegrid is down* " CEC weighted efficiency % 97 97 z5 I More than one million cumulative Nigh-time power consumption mW 60 hours of testing year limited MECHANICAL DATA warranty -A Class II double-insulated Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability enclosure Ambient temperature range -40°C to+60°C(-40°F to+140°F) Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Optimized for the latest high- Relative humidity range 4%to 100%(condensing) • Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- DC Connector type MC4 and analysis software. leading limited warranty of up to 25 years. powered PV modules Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Microgrid-forming Weight 1.08 kg(2.38lbs) Complies with the latest Cooling Natural convection-no fans advanced grid support— Approved for wet locations yes ww:c CERTIFIED Remote automatic updates for Pollution degree PD3 L SAFETY -A DRAWING BY: the latest grid requirements Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Connect PV modules quickly and easily to IQ8 Series I08 Series Microinverters are UL Listed as ara Confi ble to support Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with g PPort a w Environ.category/UV exposure rating NEMA Type 6/outdoor cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles COMPLIANCE PLOT DATE: manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 N0.107.1-01 requirements Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to PROJECT NUMBER: 02022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other *Only when installed with IQ System Controller 2, manufacturer's instructions. names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. (1)No enforced DC/AC ratio.See the compatibility calculator at https://linLenphase.com/module-compatibility **I08 and I08PIus supports split phase,240V (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required I08SP-DS-0002-01-EN-US-2022-03-17 installations only. by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. I08SP-DS-0002-01-EN-US-2022-03-17 SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: NOW- Data Sheet Enphase Q Cable Accessories BLUE RAVEN Enphase Q Cable Accessories SOLAR REGION:Americas CONDUCTOR SPECIFICATIONS Certification UL3003(raw cable),UL 9703(cable assemblies),DG cable Flame test rating FT4 Compliance RoHS,OIL RES I,CE,UV Resistant,combined UL for Canada and United States Conductortype THHN/THWN-2 dry/wet Enphase The Enphase Q Cables" and accessories are part of Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break the latest generation Enphase IQ System"'.These disconnect required by NEC 690. QCable Accessories accessories provide simplicity, reliability,and faster Q CABLE TYPES/ORDERING OPTIONS Installation times. Connectorized Models Size/Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG/277 VAC 1.3 m(4.2 ft) Portrait 240 Q-12-17-240 12 AWG/277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Q-12-20-200 12 AWG/277 VAC 2.3 m(7.5 ft) Landscape(72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Enphase Q Cable Field-wireable connector(male) Q-CONN-10M Make connections from any open connector • Two-wire,double-insulated Enphase Q Cable Field-wireable connector(female) Q-CONN-10F Make connections from any Q Cable open connector is 50%lighter than the previous generation Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Enphase cable • New cable numbering and plug and play Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors,DC connectors,and AC module mount connectors speed up installation and simplify Q Cable sealing caps(female) Q-SEAL-10 One needed to cover each unused connector on the cabling wire management • Link connectors eliminate cable waste Terminator Q-TERM-10 Terminator cap for unused cable ends Enphase EN4 to MC4 adaptor' ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4(TE PV4-S SOLARLOK). 150mm/5.9"to MC4. Enphase EN4 non-terminated adaptor' ECA-EN4-FW For field wiring of UL certified DC connectors.EN4(TE PV4-S SOLARLOK)to non-terminated cable.150mm/5.9" Field-Wireable Connectors Enphase EN4 to MC4 adaptor(long)' ECA-EN4-S22-L Longer adapter cable for EN4(TE PV4-S SOLARLOK)to MC4.Use with split cell modules or PV modules with short DC cable.600mm/23.6" • Easily connect Q cables on the roof without Replacement DC Adaptor(MC4) Q-DCC-2 DC adaptor to MC4(max voltage 100 VDC) complex wiring Replacement DC Adaptor(UTX) Q-DCC-5 DC adaptor to UTX(max voltage 100 VDC) • Make connections from any open connector and center feed any section of cable within 1.Qualified per UL subject 9703. branch limits • Available in male and female connector types TERMINATOR SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends,sold in packs of ten and cable connections (Q-TERM-10) W (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL s CABLE CLIP Plan to use at least one per Used to fasten cabling to the racking installation,sold in packs of ten orto secure looped cabling,sold in (Q-DISC-10) packs of one hundred(Q-CLIP-100) To learn more about Enphase offerings,visit enphase.com ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ To learn more about Enphase offerings,visit enphase.com u E N P H A S E. 202 026 other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. �, E N P H A S L DRAWING NUMBER: SS IQ Combiner 4/4C BLUE RAVEN Data Sheet Sol Enphase Networking MODEL NUMBER 1403 N.Research Way Orem,UT 84097 IQ Combiner 4 IQ Combiner4with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20±0.5i) X-IQ-AM1-240-4 and consumption monitoring(±2.5%).Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to 800.377.4480 X2-IQ-AM1-240-4(IEEE 1547:2018) deflect heat. WWW.BLUERAVENSOLAR.COM IQ Combiner 4C IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20±0.5%) CONFIDENTIAL-THE INFORMATION X-IQ-AM1-240-4C and consumption monitoring(±2.51/).Includes Mobile Connect cellular modem(CELLMODEM-M1-06-SP-05),a plug-and-play HEREIN CONTAINED SHALL NOT BE IQ Combiner 4/4C The IQ Combiner 4/4C with IQ Gateway and X2-IQ-AM1-240-4C(IEEE 1547:2018) industrial-grade cell modem for systems up to 60 microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the USED FOR THE BENEFIT OF ANYONE US Virgin Islands,wherethere is adequate cellular service in the installation area.)Includes a silver solar shield to match the EXCEPT BLUE RAVEN SOLAR NOR integrated LTE-M1 cell modem (included IQ Battery and IQ System Controller and to deflect heat. SHALL IT BE DISCLOSED IN WHOLE OR only with lQ Combiner 4C) consolidates ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) IN PART TO OTHERS OUTSIDE Supported microinverters IQ6,IQ7, and IQ8.(Do not mix IQ6/7 Microinverters with IQ8) RECIPIENTS ORGANIZATION,EXCEPT interconnection equipment into a single INCOFTHE ON WITH EQUIPALE MENT, D Communications Kit USE OF THE RESPECTIVE EQUIPMENT, enclosure. It streamlines IQ Microinverters and COMMS-CELLMODEM-M1-06 Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05with 5-year Sprint data plan WITHOUT THE WRITTEN PERMISSION CELLMODEM-M1-06-SP-05 4G based LTE-M1 cellular modem with 5-year Sprint data plan OF BLUE RAVEN SOLAR LLC. storage installations by providing a consistent, CELLMODEM-M1-06-AT-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. e ENPHASE pre-wired solution for residential applications. BRK-10A-2-240V Circuit breaker,2 pole,10A,Eaton BR210 NABCEP BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 It offers up to four 2-pole input circuits and BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 CERTIFIED BRK-15A-2P-240V-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support Eaton BR series busbar assembly. BRK-20A-2P-24OV-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C PV INSTALLATION XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) PROFESSIONAL X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws Scott Gurney #PV-011719-015866 Consumption monitoring CT A pair of 200A split core current transformers Smart (CT-200-SPLIT/CT-200-CLAMP) CONTRACTOR: ELECTRICAL SPECIFICATIONS BRS FIELD OPS • Includes IQ Gateway for communication and control Rating Continuous duty Includes Mobile Connect cellular modem 385-498-6700 (CELLMODEM-Ml-06-SP-05),included only with System voltage 120/240VAC,60 Hz IQ Combiner 4C Eaton BR series busbar rating 125A Includes solar shield to match Enphase IQ Battery Max.continuous current rating 65A aesthetics and deflect heat Max.continuous current rating(input from PV/storage) 64A Supports Wi-Fi,Ethernet,or cellular connectivity Max.fuse/circuit rating(output) 90A Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Provides production metering and consumption Max.total branch circuit breaker rating(input) 80A of distributed generation/95A with IQ Gateway breaker included monitoring IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway Simple MECHANICAL DATA X-IQ-AM1-240-4C Mounts on single stud with centered brackets Dimensions(WxHxD) 37.5 cm x 49.5 cm x 16.8 cm(14.75 in x 19.5 in x 6.63 in).Height is 53.5 cm(21.06 in)with mounting brackets. r • X2-IQ-AM1-240-4C(IEEE 1547:2018) Supports bottom,back and side conduit entry Weight 7.5 kg(16.5lbs) Allows up to four 2-pole branch circuits for 240VAC Ambient temperature range -400C to+46°C(-40°F to 1150F) plug-in breakers(not included) Cooling Natural convection,plus heat shield 80A total PV or storage branch circuits Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20A to 50A breaker inputs:14 to 4 AWG copper conductors Reliable 60A breaker branch input:4 to 1/0 AWG copper conductors Main lug combined output:10 to 2/0 AWG copper conductors Neutral and ground:14 to 1/0 copper conductors • Durable NRTL-certified NEMA type 3R enclosure Always follow local code requirements for conductor sizing. • Five-year limited warranty Altitude Up to 3,000 meters(9,842 feet) _ Two years labor reimbursement program coverage INTERNET CONNECTION OPTIONS included for both the IQ Combiner SKU's Integrated Wi-Fi IEEE 802.11b/g/n X-IQ-AMl-240-4 UL listed Cellular CELLMODEM-M1-06-SP-05,CELLMODEM-M1.06-AT-05(4G based LTE-M1 cellular modem).Note that an Mobile Connect • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with cellular modem is required for all Enphase Energy System installations. X2-IQ-AM1-240-4(IEEE 1547:2018) IEEE 1547:2018 rd UL 1741-SB,3 Ed. ( ) Ethernet Optional,IEEE 802.3,CatSE(or Cat6)UTP Ethernet cable (not included) COMPLIANCE Compliance,IQ Combiner CA Rule 21(UL 1741-SA) U1 IEEE 1547:2018-UL 1741-SB,31d Ed.(X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) ` CAN/CSA C22.2 No.107.1,Title 47 CFR,Part 15,Class B,ICES 003 LISTED Production metering:ANSI C12.20 accuracy class 0.5(PV production) Consumption metering:accuracy class 2.5 E N P H A S E To learn more about Enphase offerings,visit enphase.com `� Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 SHEET NAME: IQ-C-4-4C-DS-0103-EN-US-12-29-2022 ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of Enphase Energy,Inc.Data subject to change. IQ-C-4-4C-DS-0103-EN-US-12-29-2022 SPEC SHEETS REVISION: PAGE NUMBER: 0 SS JB- 1 . 2 EZf SOLAR PHONE:385-202-4150 EZf SOLAR Specification Sheet making solarslmple, WWW.EZSOLARPRODUCTS.COM FLUE RAVED making solar simple, PV Junction Box for Composition/Asphalt Shingle Roofs 1403 N.Research Way A. System Specifications and Ratings Orem,UT84097 Y p g ITEM N0. PART NUMBER DESCRIPTION OTY slzE DWG.No. REV 800.377.4480 POLYCARBONATE WWW.BLUERAVENSOLAR.COM • Maximum Voltage: 1,000 Volts 1 JB-1.2 BODY 1 CONFIDENTIAL-THE INFORMATION WITH UV INHIBITORS SCALE: WEIGHT: LBS SHEET 1 OF 3 HEREIN CONTAINED SHALL NOT BE • Maximum Current: 80 Amps USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR • Allowable Wire: 14 AWG —6 AWG 2 JB 12 LID POLYCARBONATE 1 SHALL IT BE DISCLOSED IN WHOLE OR WITH UV INHIBITORS TORQUE SPECIFICATION: 15-20 LBS N PART TO OTHERS OUTSIDE • S Spacing:: Please maintain a s acin of at least 1/2" between uninsulated live arts and fittin s for RECIPIENTS ORGANIZATION,EXCEPT p g spacing p g IN CONNECTION WITH THE SALE AND conduit, armored cable, and uninsulated live parts of opposite polarity. #10 X 1-1/4"PHILLIPS UL STANDARD 1741, USE OF THE RESPECTIVE EQUIPMENT, • Enclosure Rating: Type 3R 3 PAN HEAD SCREW NEMA 3R OF BLUE RAVEN SOLAR LLC. • Roof Slope Range: 2.5— 12:12 4 #8 X 3/4"PHILLIPS 6 WEIGHT: 1.45 LBS NABCEP • Max Side Wall Fitting Size: 1" PAN HEAD SCREW • Max Floor Pass-Through Fitting Size: 1" 1 CERTIFIED • Ambient Operating Conditions: (-35°C) - (+75°C) PV INSTALLATION • Compliance: PROFoESSIONAL Gurneytt - JB-1.2: UL1741 #PV-011719-015866 -Approved wire connectors: must conform to UL1741 CONTRACTOR: • System Marking: Interek Symbol and File#5019942 A A / .� BRS FIELD OPS • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion 385-498-6700 between components, components that are found to be affected are to be replaced immediately. Table 1:Typical Wire Size,Torque Loads and Ratings Torque 1 Conductor 2 Conductor Type NM Inch Lbs Voltage Current ABB ZS6 term I nal bl ock 10-24awg 16-24awg Sol/Str 0.5-0.7 6.2-8.85 600V 30amp ABB ZS10 terminal block 6-24 awg 12-20 awg Sol/Str 1.0-1.6 8.85-14.16 600V 40 amp ABB ZS16 terminal bock 4-24 awg 10-20 awg Sol/Str 1.6-2.4 14.6-21.24 600V 60 amp �a ABB M6/8terminal block 8-22 awg Sol/Str .08-1 8.85 600V 50 amp [279.68mm] [276.30mm] i 1 ].Olin 10.88in Ideal452 Red WING-NUTWire o Connector 8-18awg Sol/Str Self Torque Self Torque 600V SOLAR L� Ideal451YellowWING-NUT Wire Connector III III 10-18awg Sol/Str Self Torque Self Torque 600V o Ideal, Push-I Conn In-SuretorPPart 10-14awg Sol/Str Self Torque Self Torque 600V III III Connector Part#39 i o f �B-).2 i n WAGO,2204-1201 10-20 awg 16-24 awg Sol/Str Self Torque Self Torque 600V 30 amp III III WAGO,221-612 10-20 awg 10-24 awg Sol/Str Self Torque Self Torque 600V 30 amp Dottie DRC75 6-12 awg Sol/Str Snap-In Snap-In 4-6 awg Sol/Str 45 ESP NG-53 2000V 10-14 awg Sol/Str 35 ------------- ESP NG-717 4-6 awg Sol/Str 45 2000V 10-14 awg Sol/Str 35 DRAWING BY: wg Sol/Str 45 2000V Brumal1 4-5,3 14-6 a 0_14awg Sol/Str [3s [183.06mm] 72.53mm 7.21 in 2.86in PLOT DATE: Table 2:Minimum wire-bending space for conductors through a wall opposite terminals in mm(inches) [265.18mm] Wire size,AWG or Wires per terminal(pole) 10.44in 1 2 3 4 or More PROJECT NUMBER: kcmil (mm2) mm (inch) mm (inch) mm (inch) mm (inch) 14-10 (2.1-5.3) Not specified - - 8 (8.4) 38.1 (1-1/2) SHEET NAME: 6 (13.3) 1 50.8 (2) SPEC SHEET REVISION: PAGE NUMBER: EZf SOLAR PHONE:385-202-4150 1 WWW.IZSOLARPRODUCTS.COM PROPRIETARY AND CONFIDENTIAL:THE INFORMATION CONTAINED INTHIS DRAWING ISTHE SOLE PROPERTYOF EZSOLAR. ———— SS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. Rigid Nonmetallici i Boxes BLUE RAVED SP Carion• 1403 N.Research Way Molded Nonmetallic Junction Boxes Except where noted Orem UT 84097 LISTED by E42728 800.377.4480 VIEW SHOWN LESS WWW.BLUERAVENSOLAR.COM 6P Rated COVER FOR CLARITY 3.70 CONFIDENTIAL-THE INFORMATION [941 0.20 HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE It's another first from Carlon® the first nonmetallic r� [5, I 1 EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR junction boxes LIL Listed with a NEMA 6P rating per IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT Section 314.29,Exception of the National Electrical Code. /4 IN CONNECTION WITH THE SALE AND Manufactured from PVC or PPO thermoplastic molding USE OF THE RESPECTIVE EQUIPMENT, p g 3.70 WITHOUT THE WRITTEN PERMISSION compound and featuring foam-in-place gasketed lids [941 4 50 OF BLUE RAVEN SOLAR LLC. attached with stainless steel screws,these rugged [541 [12 71 enclosures offer all the corrosion resistance and physical NABCEP properties you need for direct burial applications. Type 6P enclosures are intended for indoor or outdoor CERTIFIED _ use,primarily to provide a degree of protection against PV INSTALLATION contact with enclosed equipment,falling dirt,hose- PROFESSIONAL Scott Gurney directed water,entry of water during prolonged B #PV-01 1 71 9-01 581i1i submersion at a limited depth,and external ice f CONTRACTOR: formation. BRS FIELD OPS Tc 385-498-6700 •All Carlon Junction Boxes w are LIL Listed and maintain O O_ O AT - !r a minimum of a NEMA Type �r 4/4x Rating. CO � o II • Parts numbers with an H OF B ° D asterisk(*)are LIL Listed and SIZE A e c maintain a NEMA Type 6P E989NNJ 2.00 4.63 5.13 O O RatingandT Type Rating. E989NNJB (50,8) (II7,6) (130,2) I w yp g' E989NNJ-CAR A TO E989NNJCL _ E989NNJL O O O AB T� 14X4X2) E989NNR fi.00 5.00 5.50 E989NNR-CAR 1152.d1 1127,0) 1139,7) I (4X4X6) I . 15 j Size in Std. Material Std. [3 81 Inches Ctn. Min Min. Min. Min. Ta Tc Thermo- Ctn. Part No. H x W x D Qty. AT AB B C Typical PVC plastic Wt.(Lbs.) E989NNJ-CAR* 4 x 4 x 2 5 311/16 35/8 N/A 2 .160 .155 X 3 E987N-CAR* 4x4x4 5 311/16 31/2 N/A 4 .160 .155 X 4 NOTES: I. ATERIAL: PVC SECTION 14-14 tE989NNR-CAR* 4x4x6 4 311/16 33/8 N/A 6 .160 .200 X 5 2. NEMA TYPES: 4/4X, 6P C SCALE 0,500 E989PP1-CAR* 5 x 5 x 2 4 411/16 41/2 N/A 2 .110 .150 X 3 E987R-CAR* 6 x 6 x 4 2 6 55/8 N/A 4 1 .190 .190 X 3 DRAWING BY: E989RRR-UPC* 6 x 6 x 6 8 55/8 53/8 N/A 6 .160 .150 X 14 GENERAL NOTES E989N-CAR 8 x 8 x 4 1 8 8 N/A 4 .185 .190 X 2 1. ALL DIMENSIONS ARE FOR REFERENCE ONLY. www.in— b.corn PLOT DATE: E989SSX-UPC 8 x 8 x 7 2 721/32 75/16 N/A 7 .160 .150 X 6 2. DIMENSIONS I N BRACKETS I I E989UUN 12 x 12 x 4 3 115/8 11112 111/8 4 .160 .150 x 12 ARE IN MEETTH��N I TS. DESCRIPTION: MOLDED NON-METALLIC ENCLOSURE E989R-UPC 12 x 12 x 6 2 1115/16 117/8 117/16 6 .265 .185 X 10 F PROJECT NUMBER: SEE ERN 20 16 195 FOR APPROVAL SIGNATURES ORIGINAL PROJECT NO I I ERN NO 1 1 SHEET NO: I REV. NO: I DRAWING NO: PROJECTS NO: 5AM000OD6 / 1 1 2 OF 2 F WSD-AC01977 THIS DRAWING IS INTENDED FOR DESCRIPTIVE PURPOSES ONLY. AND THE RIGHT IS RESERVED TO DEVIATE FROM ANY OF THE DETAILS SHOWN HEREON. SHEET NAME: 180 www.carIon.com Copyright Thomas A Betis - Proprietary, All Rights Reserved Gross Automation (877)268-3700 -www.carionsales.com -sales@grossautomation.com SPEC SHEET REVISION: PAGE NUMBER: ---- SS NOW- BLUE RAVEN SOLAR "Stay Connected"with Solar Power Components Heyco"-Tite Liquid Tight Cordgrips for Enphase Q Cables Straight-Thru, NPT Hubs with Integral Sealing Ring ALL NEW ;' The Ultimate in Liquid Tight Strain Relief Protection PRODUCT! GLAND PART NO. DESCRIPTION I PART DIMENSIONS •Two new cordgrips now accommodate CONFIGURATION ©/C" A B C D E the Enphase Q Cable—M3231 GCZ Conductors or Clearance Max.O.A. Thread Wrenching Nut (1/2-NPT)and M3234GDA-SM Type Size No. Black lwus Hole Dia. Length Length Thickness Flat Size mm. in. Imm. in.I mm. in.Imm. in.I mm. in.I mm. (3/4""NPT). Oval Gland •The 1/2-version provides liquid tight Q Cable I6,1 x 9,7i 1 M3231GCZ I LTCG 1/2 6.1x9.7MM (W)/SP1 .875I22,2I 1.70I43,2I.61 I15,5I.21 15,3 I .98I24,9 entry for one Enphase Q Cable— Break-Thru Skinned Over Gland .24 x.38-(6,1 x 9,7 mm). Q Cables 6,1 x9,7 2 SMCG 3/4 2-6.1x9.7MM •The 3/4-version provides liquid tight plus 3 3 1 M3234GDA-SM 1-3.3MM ©�SP 1.040 26,4 2.00 50,8 .62 15,7 .25 6,4 1.30 33,0 entry for up to two Enphase Q Cables— Ground .24 x.38"(6,1 x 9,7 mm)and an Metal Lockouts INCLUDED. B additional .130"(3,3 mm)dia.hole for C a#8 solid grounding cable. D A •The 3/4-version utilizes our skinned- over technology so any unused holes will retain a liquid tight seal. •Rated for use with DG Cable. SUGGESTED CLEARANCE HOLE SEALING NUT INTEGRAL FOR NONTHREADED MOUNTING SEALING RING Material Nylon 6/6 with TPE Sealing Gland Certifications © Listed under Underwriters'Laboratories File E504900 SP GSA Certified by the Canadian Standards Association File 93876 Flammability Rating 94V-2 Temperature Range Static -40°F(-40°C)to 239°F(115°C) Dynamic-4°F(-20oC)to 212°F(100°C) IP Rating IP 68 ALL NEW Heyco° Helios° UVX Clip - Blind Mount PRODUCT! PANEL THICKNESS RANGE WIRE DIAMETER PART NO. DESCRIPTION MOUNTING OVERALL •The jersey pine tree mounting style RANGE HOLE DIA. HEIGHT installs easily with superior holding Minimum Maximum 1-2 Wires A C power. in. I n in. mm. in. mm. in. mm. .UVX nylon protects from corrosion due 1-2 Wires to outdoor exposure. .028 0,7 .250 6,4 �.23(5,8 mm)-.32(8,0 mm)I S6520 Helios UVX Clip 100 Pack 260 6,6 .96 24,4 •Installs into.260""(6,6 mm) mounting each cable S6560 Helios UVX Clip Bulk hole. •Holds up to 2 cables between .230- T ' .315-(5,8-8,0 mm)each. C •Cables install with fingertip pressure. A •Molded from our robust UVX nylon 6/6 MOUNTING HOLE with extended UV capabilities for our T- Solar 20 Year Warranty. Material Nylon 6/6 with extended UV Capabilities Flammability Rating 94V-2 Temperature Range Dynamic -4°F(-20°C)to 185°F(85°C) 1-800-526-4182•732-286-1800(NJ)•FAX:732-244-8843•www.heyco.com DRAWING NUMBER: SS NOW- BLUE RAVEN SOLAR SFM INFINITY ::� UNIRAC :r BETTER SOLAR STARTS HERE GO DING A GRCuNnRc Wr MUM MECHANICAI SYSTEM ARE f ASSIFCA-101. SYSTEM OVERVIEW 20% FEWER ATTACHMENTS PART NAME DESCRIPTION Save time and money on every project:SFM INFINITY requires fewer attachments than rail systems. 2 INSTALLS PER DAY TRIMRAIL Structural front trim provides aesthetic and aligns modules. Make two installs per day your new standard.SFM INFINITY has fewer roof attachments,one tool installation,and pre-assembled components TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. to get you off the roof 40%faster. TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof.Available for comp shingle or tile. 8 � � OF REFER HOMEOWNERS SFM INFINITY 15 Attachments MODULE CLIPS Secure modules to TRIMRAIL. BETTER AESTHETICS MICRORAIL Connects modules to SLIDERS.Provides post-install array leveling. Install the system with the aesthetics preferred by homeowners, SPLICE Connects and supports modules.Provides east-west bonding. with integrated front trim,trim end caps,dark components,and ATTACHED SPLICE also available. recessed hardware. SLIDER FLASHKIT Roof attachment and flashing.Available for comp shingle and tile. RAIL 20 Attachments MAXIMUM POWER DENSITY 30% LOGISTICS SAVINGS Easily mix module orientations to achieve optimal power density without incurring the increased bill of materials,labor,and BONDING AND ACCESSORIES With fewer and compact components,SFM INFINITY is easier to attachments required by rail. o transport, stock,easierr t to and easier to lift to the roof.Plus,make more PART NAME DESCRIPTION efficient use of your vehicle fleet. TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules U N/S BONDING CLAMP Electrically bonds rows of modules F01104 • • LE SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS, rr L FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. DRAWING NUMBER: SS sm I NOW- SUN i BLUE RAVEN FLASHKIT MOUNTING 1 8 SOLAR ■ S F M FRAME ■ � MICRORAILTM INSTALLATIUN GU10k. ; PAGE ________________________________________________________________________________________________ INSTALL SLIDERS AND ROOF ATTACHMENTS: Follow manufacturer instructions UP-SLOPE for flashing installation procedures 0 1 1 PILOT HOLES: FLASHINGS: Drill pilot holes for lag screws or Place flashings Mod NS + 1" structural screws (as necessary) at marked attachment points /UNIRAC NOTE: If N-S module edge is within 1"of the o shingle course above,you have the option to pivot/rotate slider at the attachment point to span the next course and cut shingles as required. Cut Shingles as Required I 'uy' 1 ya 1 Mod NS + 1„ Rotate Slider I Bt 1 ?tll III INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: N/5 MODULE EDGE -- --- » -' �OTE: Insert flashings per manufacturer instructions -Less Than 1 - --- -------11 _ Use Lag screw or structural fastener with a maximum diameter of 5/16" "' 0 PII • Attach sliders to rafters • Verify proper row to row spacing for module size (Mod NS + 1") II IIII III I IIII III I • Ensure that Trimrail TM roof attachments in each row have sufficient engagement with slider dovetails for proper attachment. .",. ,a DOWN-SLOPE ----------- DRAWING NUMBER: SS NOW- SUN i BLUE RAVEN Id TR MRAIL & MICRORAIL INSTALLATIONFRAME 11 SOLAR ■ ■ S F M MICRORAILTM INSTALLATION GUIDL ; PAGE -----------------------------------------------------------_____________________________________ ATTACH TRIMRAIL TO ROOF ATTACHMENT: INSTALL MODULE CLIPS ON TRIMRAIL: NOTE: module clips may be pre-installed on trimrail Attach rail using 3/8" hex bolt & Tri-drive or Attach module clips to Trimrail using 3/8" prior to attaching trimrail to roof attachments serrated flange nuts. Make sure TrimrailTM is T-bolts and Tri-drive or serrated flange nuts.A level across all TrimrailT'" roof attachments. minimum of two clips are required per module. After rail is level,tighten channel clamp Refer to SFM D&E guide and U-builder for bolts to secure TrimrailT"' roof attachments required position and quantity of module clips. to channels. _ i ......... 40 -40 40 BONDING PINS: ^ -Z :35 g -30 a30 \ EEZE- an POSITION MODULE CLIPS ACCORDING TO NOTE:Bonding pin on Microrails should be positioned downslope. MODULE THICKNESS: INSTALL MICRORAILS: Align notch in module clip with trimrail rib Install MicrorailTm at marked attachment points. Click according to module thickness (identified in Microrai[TM into sliders and push MicrorailT"' to top of slider. mm on faces of module clips). Rotate clip to Ensure that cap remains in upper most (40mm) position. DRAWING NUMBER: position at required location. SS SYSTEM BONDING & GROUNDING NOW- SUN i BLUE RAVEN 1 9 SOLAR ML S F M FRAME ■ ■ MICRORAILTM INSTALLATION GUIDL ; PAGE ________________________________________________________________________________________________ J1 E-W BONDING PATH: E-W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicrorailTM and splice. I I Star Washer is WEEBLUG Single Use Only Single Use Only Alternate method N-S BONDING PATH: TERMINALTOROUE, N-S module to module bonding is Install Conductor and accomplished with bonding clamp with 2 integral torque to the following: TERMINALTOROU� TERMINALTOROUE, v bond ng pi ns. (refer also to alternate method) 4-6 AWG: 35in-lbs Install Conductor and Install Conductor and 8 AWG: 25 in-lbs torque to the following: torque to the following: 10-14 AWG:20 in-lbs 4-14 AWG: 35in-lbs 6-14 AWG: 7ft-lbs LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO Ilsco Lay-In Lug (GBL-4DBT) Ilsco Flange Lug (SGB-4) Wiley WEEBLug (6.7) • 10-32 mounting hardware 0 1/4" mounting hardware 0 1/4" mounting hardware • Torque = 5 ft-lb 0 Torque = 75 in-lb 0 Torque = 10 ft-lb Alternate method • AWG 4-14-Solid or Stranded 0 AWG 4-14-Solid or Stranded 0 AWG 6-14-Solid or Stranded TRIMRAIL BONDING PATH: NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION Trimrail to module bonding is accomplished with System bonding is accomplished through modules.System grounding accomplished by attaching bonding clamp with integral bonding pin and a ground lug to any module at a location on the module specified by the module manufacturer. bonding T-bolt. (refer also to alternate method) DRAWING NUMBER: SS i NOW- SUN i BLUE RAVEN UL CODE COMPLIANCE NOTES 0 SOLAR so S F M FRAME ■ ■ MICRORAILTM INSTALLATION GUIDL ; PAGE -----------------------------------------------------------__________________________----------- SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the performance is inherent in the SFM design,and no additional mitigation measures SUNFRAME MICRORAIL (SFM) Installation Guide. SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no the system level fire portion of UL 1703. This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM. SUNFRAME MICRORAILTm components shall B & C system level performance for low slope & steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. in conjunction with type 1 and type 2 modules. Class A, B & C system level fire Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 Steep Slope & Low Slope Class A, B & C East-West Landscape OR Portrait None Required UL2703 TEST MODULES See pages 22 and 23 for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 27.76 sqft • UL2703 Design Load Ratings: a) Downward Pressure - 113 PSF / 5400 Pa b) Upward Pressure - 50 PSF / 2400 Pa c) Down-Slope Load - 21.6 PSF / 1034 Pa • Tested Loads: a) Downward Pressure - 170 PSF / 8000 Pa b) Upward Pressure - 75 PSF / 3500 Pa c) Down-Slope Load - 32.4 PSF / 1550 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • PV modules may have a reduced load rating, independent of the SFM load rating. Please consult the PV module manufacturer's installation guide for more information • Down-Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or less DRAWING NUMBER: SS NOW- BLUESUN RAVEN FRAME UL CODE COMPLIANCE NOTES Z1SOLAR ■ ■ S F M MICRORAILTM INSTALLATION GUIDL ; PAGE ________________________________________________________________________________________________ LABEL MARKINGS • System fire class rating: See installation instructions for installation requirements to achieve a specified system fire class rating with Unirac. • Unirac SUNFRAME MICRORAILTm is listed to UL 2703. • All splices within a system are shipped with marking indicating date and location of manufacture. ® 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 'xxaom sim Him N-N HAW 3+➢N0Nn 0.1 0SIYd 1�9W3NOfA33N NOI1Y11Y1SNI=A 411=nU1.5N1 0 EOCL aLS in oA SWLOiWaD 9d5:9MMdO 55VD1 NNOd W315AS AAAAIWW WdS OYNON01 o a o 0 a o a 0 0 0 0 0 0 0 0 0 0 2 INCH MINIMUM MODULE[ENGAGEMEN7 DRAWING NUMBER: SS i NOW- SUN TESTED / CERTIFIED MODULE LIST i 22 BLUE RAVEN I I SOLAR so S F M FRAME ■ ■ MICRORAILTM INSTALLATION GUIR ; PAGE -----------------------------------------------------------_____________________________________ Manufacture Module Model/Series Manufacture Module Model/Series Manufacture Module Model/Series i Aleo P-Series Eco SoLargy Orion 1000 &ApoLLo 1000 LGxxxN2T-A4 ET Solar ET-M672BHxxxTW LGxxx(A1C/E1C/E1K/N1C/N1K/N2T/N2W/ DNA-120-(BF/MF)26 01C/01K/S1C/S2W)-A5 Aptos Freedom Forever FF-MP-BBB-370 DNA-144-(BF/MF)26 FreeVolt Mono PERC LGxxxN2T-B5 LGxxxN1K-B6 CHSM6612P,CHSM6612P/HV,CHSM6612M, GCL GCL-P6 &GCL-M6 Series LGxxx(A1 C/M 1C/M 1 K/N 1 C/N 1 K/01 C/01 K/ Astronergy CHSM6612M/HV,CHSM6610M (BL)(BF)/(HF), Hansol TD-AN3,TD-AN4, LG Electronics OAC/OAK)-A6 CHSM72M-HC UB-AN1,UD-AN1 LGxxx(N1C/N1K/N2T/N2W)-E6 Auxin AXN6M610T,AXN6P610T, 36M,60M,60P,72M & 72P Series, LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 AXN6M612T&AXN6P612T Heliene 144HC M6 Monofacial/Bifacial Series, LGxxxN2T-J5 AXIblackpremium 60(35mm), 144HC M10 SL Bifacial LGxxx(N1K/N1W/N2T/N2W)-L5 AXIpower 60(35mm), HT Solar HT60-156(M) (NDV) (-F), LGxxx(N1C/01C/01K)-N5 Axitec AXIpower 72 (40mm), HT 72-156(M/P) LGxxx(N1C/N1K/N2W/01C/01K)-V5 AXIpremium 60(35mm), Hyundai KG,MG,TG,RI,RG,TI,MI,HI & KI Series LR4-60(HIB/HIH/HPB/HPH)-xxxM AXIpremium 72 (40mm). HiA-SxxxHG LR4-72(HIH/HPH)-xxxM Boviet BVM6610, ITEK iT,iT-HE & iT-SE Series LR6-60(BP/HBD/HIBD)-xxxM(30mm) BVM6612 Japan Solar JPS-60 &JPS-72 Series LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35mm) BYD P6K& MHK-36 Series LONG LR6-60(BK)(PE)(PB)(PH)-xxxM (40mm) CS1(H/K/U/`r)-MS JAP6 60-xxx,JAM6-60-xxx/SI,JAM6(K)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM (30mm) CS3(K/L/U),CS3K-MB-AG,CS3K-(MS/P) xxx,JAP6(k)-72-xxx/4BB,JAP72SYY-xxx/ZZ, LR6-72(HV)(BK)(PE)(PH)(PB)(HPH)-xxxM Canadian Solar CS3N-MS,CS3U-MB-AG,CS3U-(MS/P),CS3W JAP6(k)-60-xxx/4BB,JAP60SYY-xxx/ZZ, (35mm) JASolar JAM6(k)-72-xxx/ZZ,JAM72SYY-xxx/ZZ, LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM (40mm) CS5A-M,CS6(K/U),CS6K-(M/P),CS6K-MS JAM6(k)-60-xxx/ZZ,JAM60SYY-xxx/ZZ. CS6P-(M/P),CS6U-(M/P),CS6V-M,CS6X-P i.YY:01,02,03,09,10 Mission Solar Energy MSE Series CentrosoLar America C-Series & E-Series ii.ZZ:SC,PR,BP,HiT,IB,MW,MR Mitsubishi MJE & MLE Series CT2xxMxx-01,CT2xxPxx-01, JKM &JKMS Series Neo Solar Power Co. D6M & D6P Series CertainTeed CTxxxMxx-02,CTxxxM-03, CTxxxMxx-04,CTxxxHC11-04 Jinko Eagle JKMxxxM JKMxxxM-72HL-V Dehui DH-60M Kyocera KU Series • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information DRAWING NUMBER: SS i NOW- SUNTESTED / CERTIFIED MODULE LIST i 23 BLUE RAVEN SOLAR so S F M FRAME ■ ■ MICRORAILTM INSTALLATION GUIR ; PAGE -----------------------------------------------------------_____________________________________ Manufacture Module Model/Series Manufacture Module Model/Series Manufacture Module Model/Series EVPVxxx(H/K/PK), TwinPeak Series Suniva MV Series & Optimus Series VBHNxxxSA15 & SA16, TwinPeak 2 Series A-Series A400-BLK,SPR-MAX3-XXX-R, SunPower VBHNxxxSA17& SA18, REC Solar(cont.) TwinPeak 2 BLK2 Series X-Series,E-Series & P-Series Panasonic VBHNxxxSA17(E/G) & SA18E, TwinPeak 2S(M)72(XV) Suntech STP,STPXXXS-B60/Wnhb VBHNxxxKA01 & KA03 & KA04, TwinPeak 3 Series(38mm) TP572,TP596,TP654,TP660, VBHNxxxZA01,VBHNxxxZA02, TP4(Black) Talesun TP672,Hipor M,Smart VBHNxxxZA03,VBHNxxxZA04 Renesola Vitrus2 Series & 156 Series SC,SC B,SC B1,SC B2 Peimar SGxxxM FB/BF Risen RSM72-6 MDG M ,RSM60-6 Tesla ( ) ( )( ) TxxxH,TxxxS Phono Solar PS-60,PS-72 SEG Solar SEG-xxx-BMD-HV PA05,PD05,DD05,DE06,DD06,PE06, Prism Solar P72 Series SEG-xxx-BMD TB Trina PD14,PE14,DD14,DE09.05,DE14,DE15, Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) S-Energy SN72 & SN60 Series(40mm) PE15H Pro,Peak L-G2,L-G4,L-G5,L-G6,L-G7 Seraphim SEG-6 & SRP-6 Series UP-MxxxP(-B), Upsolar O.PEAK DUO BLK-G6+ Sharp NU-SA& NU-SC Series UP-MxxxM(-B) O.PEAK DUO BLK-G6+/TS Silfab BLK-G8 SLA, SLG,BC Series & SlLxxx(BL/NL/NT/HL/ D7MxxxH7A,D7(M/K)xxxH8A O.PEAK DUO + ( ) ( ) ML/BK/NX/NU/HC) United Renewable Energy FAKxxx(C8G/E8G),FAMxxxE7G-BB O.CeLLs O.PEAK DUO L-G8.3/BFF SoLarever USA SE-166*83-xxxM-120N (URE) FAMxxxE8G(-BB) O.PEAK DUO(BLK) ML-G9(+) FBMxxxMFG-BB PowerXT-xxx R-(AC/P D/B D) O.PEAK DUO XL-G9/G9.2/G9.3 Eldora, Solaria PowerXT-xxxC-PD O.PEAK DUO(BLK) ML-G10(+) PowerXT-xxxR-PM (AC) Vikram SoLivo, O.PEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Somera Sunmodule Protect, O.PEAK DUO BLK ML-G10+/t SoLarWorLd � Sunmodule Plus Waaree AC&Adiya Series Alpha (72)(Black)(Pure) SS-M-360 to 390 Series, Winaico WST&WSP Series RECxxxAA PURE-R RECxxxNP3 Black SS-M-390 to 400 Series, YingLi YGE &YLM Series N-Peak(Black) Sonali SS-M-440 to 460 Series, ZN Shine ZXM6-72, ZXM6-NH144-166 2094 - REC Solar N-Peak 2 (Black) SS-M-430 to 460 BiFacial Series, PEAK Energy Series SS 230-265 PEAK Energy BLK2 Series SunEdison F-Series,R-Series & FLEX FXS Series PEAK Energy 72 Series • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM DRAWING NUMBER: • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section,page 12 for further information SS Ne- on , SUN � BLUE RAVEN SLIDERS , G MM FRAME 1403 N RESEARCH WAY,BUILDING J SFM■■ REM,UT MICRORAILTM INSTALLATION GUIDI 'I PAGE O8 0-37744807 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE INSTALL SLIDERS AND USED FOR THE BENEFIT OF ROOF ATTACHMENTS: 4ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART Follow manufacturer instructions UP-SLOPE TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN for flashing installation procedures CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. s NABCEP CERTIFIED PV INSTALLATION IONAL PILOT HOLES: FLASHINGS: PRO Scott FEssney Drill pilot holes for lag screws or Place flashings Mod NS + 1" #PV-01 1719-015866 structural screws (as necessary) at CONTRACTOR: marked attachement points BRS FIELD OPS 385.498.6700 ti- -�; NOTE: If N ! -5 module edge is within 1"of thL r I __ shingle course above,you have the option to pivot/rotate slider at the attachment point to span the next course and cut shingles as required. Cut shingles as Required - __ I Mod NS+ 1" Rotate Slider INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: -- -N,> 1000LE EDGE !! it • InsertflashIngs per manufacturer instructions LessT1 - .�:. .,, Aimum diameter of 5/16" • Attach sliders to rafters • Verify proper row to row spacing for module size (Mod NS + 1') • Ensure that TrimrailTM roof attachments in each row have sufficient II I II I engagement with slider dovetails for proper attachment. I DOWN-SLOPE ---------- ----- SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0