HomeMy WebLinkAboutEngineering 861-E N Dean Road STARK Auburn, AL 36830 FO U N DATA O N S P: 360.566.7343 STRUCTURAL CALCULATIONS PREPARED FOR DBS REPAIR FOR RENTSCH RESIDENCE FOUNDATION REPAIR 286 RICE CREEK BLVD NE FRIDLEY, MINNESOTA PROJECT NUMBER: 23.200.DBS DATE: December 13, 2023 PROJECT MANAGER: Daniel Stark, P.E. I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.SIGNATURE: �� J--� NAME: NATHAN DANIEL W STARK DATE: 12.13.23 LICENSE NUMBER: 59100 *Its;STARK 861-E N Dean Road FOUNDATIONS Auburn, AL 36830 P: 360.566.7343 December 13, 2023 Project No.:23.200.DBS DBS Repair 5116 Jean Duluth Road Duluth, Minnesota 55803 RE: Foundation Repair - 286 Rice Creek Blvd NE, Fridley, Minnesota PROJECT BACKGROUND We understand the structure is a single-family residence with a garage supported by an 8 inch CMU walls. The homeowner wishes to permanently stabilize the rear CMU walls of the garage. It is our understanding (4) GeoLok wall anchor systems have been proposed to provide additional wall support. A recent field sketch (attached) indicates the approximate locations of repair. Image 1: Front Elevation GEOLOGIC SETTING The existing structure is located in Fridley, Minnesota. Based on the information provided by the USDA Web Soil Survey, the general site condition in the area is comprised of sand and the site is moderately sloping. We believe suitable wall reinforcement can be achieved by installing Geol-ok wall anchors. SUMMARY Based on the geologic setting and design load tables (attached), we recommend the wall anchors be spaced at a maximum of 5'. This is based on a conservative EFP of 75 psf/ft (alternate EFP may be considered depending on site conditions). Please reference design drawings for layout and connection details. Regards, D Daniel Stark, P.E. Stark Foundations FIELD SKETCH ,o house A Front Garage ~ Date: 13-Dec-23 U STARK LU Foundation Repair Designed by: SCA FOUNDATIONS ­3 286 Rice Creek Blvd NE 0 Fridley, Minnesota a Project No.: 23.200.DBS Design Criteria Code(s): 2020 Minnesota Building Code International Building Code (IBC) 2018 ASCE 7-16 Design Loads: Dead: Soil: Roof = 15 psf Allow Lateral Bearing Pressure = 100 psf/ft Chimney= 45 psf Active Pressure = 60 psf/ft Third Floor= 15 psf Second Floor= 15 psf First Floor (4" Conc. Slab) = 50 psf Walls = 8 psf 8" Foundation Wall = 100 psf Soil = 110 psf Live: Roof (Snow) = 50 psf Roof Live Load = - psf Third Floor= 40 psf Second Floor= 40 psf First Floor (4" Conc. Slab) = 40 psf Wind: (not applicable) Exposure = C Risk Category= II Wind Speed, V= 109 mph Kzt= 1 Gust Factor, G = 0.85 Kd = 0.85 Int. Pressure Coefficient, GCp; _ -0.18 KZ = 1 Ext. Pressure Coefficient, Cp= 0.8 Height, hZ = 30 ft Design Wind Pressure: Design Load Combo = D + 0.6W where: pW= qZ (GCp- GCp;) w = 0.6 qZ= 0.00256 KZ Kt Kd V2 Therefore: qZ= 25.9 psf pW= 22.2 psf Factored Wind Pressure, p'W= 13.3 psf (say 14 psf) I-- V Date: 13-Dec-23 STARK LLB Foundation Repair Designed by: SCA FOUNDATIONS O 286 Rice Creek Blvd NE 0 Fridley, Minnesota a Project No.: 23.200.DBS Wall Anchor Design Site Data: Wall Height = 6 ft Soil Description: Silt, Silty/Clayey Sand and Gravel Soil Height = 6 ft Frost Depth = 42 in Anchor Sizes: Small (16 in x 16 in) Vertical Anchor Dimension = 16 in Medium (16 in x 26 in) <-- Assumed Large (26 in x 26 in) Design Values from Design Table P =2ft P =3ft h = 10.3 ft h = 11.0 ft Avb = 4.1 ft Avb = 4.5 ft Calculated A„b for frost depth Avb = Frost Depth + Vertical Anchor Dimension Avb = 58 in Alb = 4.8 ft Calculated At from greater A„b value P = 2ft P =3ft Avb = 4.8 ft 7= 4.8 ft Avt= 42 in Avt= 42 in A,,t= 3.5 ft Avt= 3.5 ft Wall Anchor Design Table Soil Description: Silt, Silty/Clayey Sand and Gravel = 26 degrees MI Anchor Size Anchor Size Anchor Size Anchor Size Anchor Size S M/L S M/L S M/L S M/L S M/L 10 12.1 12.8 12.1 12.8 12.8 13.5 14.4 15.1 16.0 16.7 9 11.5 12.2 11.5 12.2 12.2 12.8 13.8 14.4 - - :. 8 10.9 11.5 10.9 11.5 11.5 12.2 13.1 13.8 - - a� 7 10.2 10.9 10.2 10.9 10.9 11.6 - - - - 6 9.6 10.3 9.6 10.3 10.3 F 11.0 - - - - 0 5 9.0 9.7 9.0 9.7 - - - - - - N 4 8.4 9.0 8.4 9.0 - - - - - - 3 7.7 8.4 - - - - - - - - "Alb&At" Minimum Required Depths Below Grade to Anchor(ft) Bottom - Avb 3.7 4.1 3.7 1 4.1 4.1 1 4.5 5.1 5.5 6.1 6.5 Top-Avt Depth as needed to prevent frost effects I& STARK FOUNDATIONS 861-E N DEAN ROAD AUBURN,AL 36830 19,} P:360.566.7343 v✓wvdstarkfoun dations.com (4) WALL ANCHORS ® 5' O.C. MAX " MAX MAX (N) WALL ANCHOR SEE DETAIL 1/S2.0 (TYP OF (4) ANCHORS) C-' N (E) GARAGE--' (E) HOME-, 62'± FRONT OF HOME 1 PARTIAL FOUNDATION REPAIR EL&N[—o SCALE: 1/8'=1'-0' PLAN NOTES: NORTH 1. WALL REINFORCEMENT CAN BE ADJUSTED A DISTANCE OF 1'-0"±AS LONG AS THE MAXIMUM RECOMMENDED SPACING IS NOT EXCEEDED. WHEN THE DISTANCE EXCEEDS THE MAXIMUM RECOMMENDED SPACING, CONSULT WITH THE ENGINEER OF RECORD FOR FURTHER DIRECTION. STAMP PROJECT I HEREBY CERTIFY THAT THIS PLAN, FOUNDATION REPAIR SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION RENTSCH RESIDENCE AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS 286 RICE CREEK BLVD NE k OF THE STATE OF MINNESOTA.Q n FRIDLEY, I N SIGNATURE: NO REVISIONS BY DATE NAME: NATHAN DANIEL W STARK CLIENT ISSUED: 12.13.23 PROJ NO.: 23.200.DBS DATE: 12,13.23 LICENSE NUMBER: 59100 z, DRAWN BY: TLD I CHECKED BY: IDSDBS REPAIR SHEET TITLE 5116 JEAN DULUTH RD FDN REPAIR PLAN DULUTH, MN SHEET NUMBER FRONT ELEVATION Si •0 I& STARK FOUNDATIONS 861-E N DEAN ROAD AUBURN,AL 36830 P:360.5 66.7343 v✓wvdstarkfoun dations.com Ah (SEE TABLE) SAW-CUT (E) SLAB & FILL/REPAIR WITH CONCRETE AFTER INSTALLATION f. m I DEPTH TO aTOP OF EARTH ANCHOR PLATE SHALL NOT BE LESS THAN LaLiE THAT REQUIRED FOR FROST DEPTH m o J lA Q Of W > W Li p W J Cn -H W L- O o SUPPORTWORKS GEOLOCK WALL ANCHOR KIT `o MIN ULT TENSILE RATING = 85 KIPS II (E) CMU WALL w GEOLOCK X (E) GRADE GEOLOCK DESIGN TABLE ANCHOR PLATE Pv Avb Ah 2'-0" 4'-10" 10'-4" 3'-0" 4'-10" 11'-0" 'e �1 GARAGE WALL-WALL ANCHOR DETAIL SCALE: 3/8'=1'-0' STAMP PROJECT I HEREBY CERTIFY THAT THIS PLAN, FOUNDATION REPAIR SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION RENTSCH RESIDENCE AND THAT I AM A DULY LICENSED I 9 f PROFESSIONAL ENGINEER UNDER THE LAWS 286 RICE CREEK BLVD NE OF THE STATE OF MINNESOTA. SIGNATURE: �2 FRIDLEY, MN NO REVISIONS BY DATE NAME: NATHAN DANIEL W STARK CLIENT ISSUED: 12.13.23 PROJ NO.: 23.200.DBS DATE: 12,13.23 LICENSE NUMBER: 59100 DS DBS REPAIR DRAWN BY: TLD CHECKED BY: i"r SHEET TITLE 5116 JEAN DULUTH RD DETAILS DULUTH, MN rSHEET NUMBER FRONT ELEVATION S``j •0