HomeMy WebLinkAboutGeoLock Technical Specs GeoLock® Wall Anchor System Technical Specifications
Plate Steel: Finish:
ASTM A1011 C1008-C1010,10 gauge plate Unless noted otherwise,all components are
embossed with two(2)longitudinal ribs hot-dip galvanized in accordance with ASTM
A123 orASTM A153
Wall Plates:
Two sizes: 12"x 18" and 12"x 28" Alternate Wall Bracing Detail:
C6 x 8.2 steel channel,ASTM A36
Earth Plates: Channel secured at base with steel bracket
Fabricated from two wall plates or cast into concrete.Bracket is
welded in a cross pattern 3.75"x 1.75"x 0.25"thick x 4.5" long bent plate,
One inch on each end of wall plates ASTM A36,with(2)00.625" holes.
is bent 90 degrees (2)0112"x 3"concrete screw anchors(3�
Three sizes: 16"x 16", 16"x 26",and 26"x 26"
All-Thread Rod:
Medium Carbon Steel Standard Wall Plate Detail
80" long(assembly consists of two rods)
3/4- 10 UNC 2A
Tensile strength=85 ksi(min.) ■ • 4)
Allowable tensile capacity= 14 kips
Rod Coupler:
3" long x 0.984" diameter,AISI 1144
3/4- 10 UNC 213,oversized tap
Yield strength= 100 ksi(min.)
Tensile strength= 115 ksi(min.)
Alternate Channel Detail
Termination Hardware:
SAE J995 Grade 2 heavy square nuts
3/4- 10 UNC 213,oversized tap
Hemispherical Washer: one
Two-piece machined steel washer
ASTM A108 Grade 1018 or 1215
Yield strength= 54 ksi(min.)
Tensile strength=64 ksi(min.)
02.00"x 0.70"assembled
Bright electrozinc coating perASTM B633
41*
(1) Installation of any tieback or anchorsystem in potential landslide or hillside creep soils should be designed by a professional engineer.
(2) Referto Section 3.2.2 of the Foundation Supportworks Technical Manual for recommendations on anchorspacing,depth and location
of earth plate,and installation torque.
(3) Concrete slab should be intact and have a thickness of at least 3.5". For broken or thin slabs,contact Foundation Supportworks for
alternative installation guidelines.
02021 Supportworks® Appendix3A
All Rights Reserved 301 GeoLock®Wall Anchor System