Loading...
HomeMy WebLinkAboutRiver Edge Blu Dot_TEMP EXITING_10-27-26BUILDING CODE: 2020 MINNESOTA BUILDING CODE (2018 IBC) EXISTING BUILDING CODE:2020 MINNESOTA CONSERVATION CODE FOR EXISTING BUILDINGS FUEL CODE:2020 MINNESOTA MECHANICAL AND FUEL GAS CODE MECHANICAL CODE:2020 MINNESOTA MECHANICAL AND FUEL GAS CODE PLUMBING CODE:2020 MINNESOTA PLUMBING CODE ELECTRICAL CODE:2023 NATIONAL ELECTRICAL CODE FIRE CODE:2020 MINNESOTA STATE FIRE CODE ENERGY CODE: 2024 MINNESOTA ENERGY CODE ACCESSIBILITY CODE:2020 MINNESOTA ACCESSIBILITY CODE CITY:FRIDLEY COUNTY:ANOKA APPLICABLE CODES LIFE SAFETY PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN NEW CONSTRUCTION DISTANCE- COMMON PATH OF TRAVEL DISTANCE- EGRESS PATH C1 11'-1" E3 11'-1" 1. REFER TO ENGINEERING DRAWINGS FOR ALL EMERGENCY FIXTURES. 2. SMOKE AND FIRE RESISTANCE RATINGS SHOWN ARE MINIMUM RATINGS REQUIRED. REFER TO PARTITION TYPES ON A9-2 FOR MORE INFORMATION. 3. SMOKE AND FIRE RESISTANCE RATINGS IN PARTITIONS ARE SHOWN WHERE PARTITIONS ARE NOT CUT BY DOORS, WINDOWS, STOREFRONTS, OR OTHER OBJECTS. RATED PARTITION MAY EXIST ABOVE OBJECTS. FIRE EXTINGUISHER NOTE: FIRE EXTINGUISHERS AT WAREHOUSE AREA NOT SHOWN. PROVIDE FIRE EXTINGUISHERS AS REQUIRED FOR MAXIMUM 75' TRAVEL DISTANCE TO AN EXTINGUISHER EXIT SIGN LIFE SAFETY PLAN NOTES FE NOT IN CONTRACT (NIC) DISTANCE TO RESTROOMS 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 A B C D E F G 9 242931 SF WAREHOUSES AN-1 2 AN-1 3 207' -2"E4 A-B = 497' C-B = 531' C-D = 498' C A-D = 600' A B D 10 11 G 9 284 SF ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED 363 SF EXERCISE ROOMS 2421 SF BUSINESS GENERAL 876 SF ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED 29 SF BUSINESS GENERAL 135 SF ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED CONFERENCE 102 EXERCISE ROOM 117 OFFICE 104 OFFICE 105 OFFICE 106 SERVER 107 WOMEN'S RESTROOM 110 MEN'S RESTROOM 111 STORAGE 116 JANITOR'S CLOSET 113 PRODUCT DISPLAY 103 OPEN OFFICE 108 WAITING 101 VESTIBULE 100 VENDING 114 HALL 112 EMPLOYEE LOUNGE 109 EMPLOYEE BREAK 115 63' -10"E2 114' -5"E1 61' -9"C1 90' -8"E3 FE FE A 9 472 SF BUSINESS GENERAL OCCUPANCY SEPARATIONS:TYPE TO TYPE REQUIRED SEPARATION NOTES OFFICE TO WAREHOUSE:B S-1 N OFFICE TO ASSEMBLY: B A-3 N SEE NOTE #6 SEE NOTE #6 ASSEMBLY TO WAREHOUSE:A-3 S-1 N SEE NOTE #6 1. NON-SEPARATED USES - OCCUPANCIES SEC. 508.3. 2. FIRE RATING REDUCED BY 1 HOUR FOR SPRINKLER SYSTEM (TABLE 508.4). 3. ACCESSORY AREAS OCCUPYING 10% OR LESS OF THE AREA OF ANY FLOOR AND NOT MORE THAN THE AREA OR HEIGHT LISTED IN TABLES 504.3, 504.4 AND 506.2 ARE NOT REQUIRED TO BE SEPARATED (SEC. 508.2). 4. SQUARE FEET PER OCCUPANT DETERMINED BY TABLE 1004.5. 5. EXIT WIDTH DETERMINED BY SECTION 1005.3. 6. UNLIMITED AREA BUILDING PER MN BUILDING CODE SECTION 507.4. SUITE CIRCULATION: COMPLIANT SUITE DOOR CLEARANCES: SUITE RESTROOMS: SUITE SINKS: WORKROOM MILLWORK: COMPLIANT COMPLIANT COMPLIANT N/ASUITE COAT CLOSETS: N/A PROVIDED/EXISTINGREQUIRED NUMBER REQUIRED:2 22 EXIT SEPARATION:1/3 SUITE DIAGONAL COMPLIANT EXIT WIDTH:(2) 32"(19) 34", (3) 68" DOOR SWING DIRECTION:OUT OUT EXIT ACCESS TRAVEL DISTANCE:A-3, S-1: ≤ 250' B: ≤ 300' COMMON PATH OF EGRESS DISTANCE:A-3: ≤ 75' B, S-1: ≤ 100' MAXIMUM DEAD-END CORRIDOR:≤ 50' C1: 61'-9" E1: 114'-5" E4: 207'-2" E2: 63'-10" E3: 90'-8" N/A PLUMBING FIXTURE ANALYSIS NOTES BASED ON EMAIL EXCHANGES WITH TONY DEFORGE, BUILDING OFFICIAL, CITY OF FRIDLEY: 1. SINCE THE BREAK ROOM AND EXERCISE ROOM ARE USED BY EMPLOYEES ONLY AND ARE ACCESSORY USES TO THE S-1 OCCUPANCY, THESE ROOMS CAN BE FIGURED AT 150 SF/OCCUPANT FOR PURPOSES OF PLUMBING CALCULATIONS. 2. MAXIMUM TRAVEL DISTANCE TO RESTROOMS CAN BE INCREASED FROM 500' TO NO MORE THAN 600' IN THE WAREHOUSE AREA PER MN BUILDING CODE, EXCEPTION TO SECTION 2902.3.3. I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed Architect under the laws of the State of Minnesota NORTH Key Plan: RELEASED FOR CONSTRUCTION Reviewed By:Proj #: Mary B. Hustad 17408 8/ 2 6 / 2 0 2 6 4 : 3 5 : 4 1 P M A u t o d e s k D o c s : / / R i v e r E d g e B u s i ne s s C e n t e r B l u D o t / C D 0 1 _ R i v e r E d g e B C B l u D o t . r v t AN-1 LIFE SAFETY PLAN 2 OF 20 26.0001915.001 MBH BLU DOT RIVER EDGE BUSINESS CENTER 7350 COMMERCE LANE FRIDLEY, MN 55432 1/32" = 1'-0"AN-1 LIFE SAFETY PLAN1 Nelson Architecture & Interiors, Inc. 901 Marquette Avenue South Suite 2850 Minneapolis, MN. 55402 WWW.NELSONWORLDWIDE.COM Phone: (612) 822-1211 1/8" = 1'-0"AN-1 ENLARGED OFFICE - LIFE SAFETY PLAN2 1/8" = 1'-0"AN-1 ENLARGED WAREHOUSE OFFICE - LIFE SAFETY PLAN3 LIFE SAFETY - OCCUPANCY OCCUPANCY SEPARATIONS NOTES ACCESSIBILITY LIFE SAFETY - EXITING OCCUPANCY SCHEDULE USE OCCUPANCY CLASSIFICATION AREA LOAD FACTOR (SF/PERSON) CALCULATED OCCUPANT LOAD ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED B 284 SF 15 NET 19 ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED A-3 876 SF 15 NET 58 ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED B 135 SF 15 NET 9 BUSINESS GENERAL B 2,421 SF 150 16 BUSINESS GENERAL B 29 SF 150 0 BUSINESS GENERAL B 472 SF 150 3 EXERCISE ROOMS B 363 SF 50 7 WAREHOUSES S-1 242,931 SF 500 486 247,509 SF 599 Issue: No: Date: ISSUE FOR PERMIT & CONSTRUCTION 08/26/2026 PLUMBING CALCULATIONS AS ACCEPTED BY TONY DEFORGE: The multistall restrooms in the office area are used both by office and warehouse employees. The break room and gym are figured at 150 sf/occupant for plumbing calculations, since these spaces are used by employees already accounted for. Plumbing calculations are as follows: Warehouse: 486 people; 243 men/243 women. Required toilets (1:100): 2.43 each; required lavs (1:100): 2.43 each. Office: 56 people; 28 men/28 women. Required toilets (1:25 for first 50; 1:50 thereafter): 1.12 each; required lavs (1:40 for first 50; 1:80 thereafter): 0.70 each Total toilets required each, men and women: 2.43 + 1.12 = 3.55. Round up to 4 each. Total lavs required each, men and women: 2.43 + 0.70 = 3.13. Round up to 4 each. MN Building Code section 2902.1.1 states that “For calculations involving multiple occupancies, such fractional numbers for each occupancy shall first be summed and then rounded up to the next whole number.” Totals are consistent with this method. Calculations based on figuring the break/lounge and gym at 150 sf/occupant since those spaces are not adding people to the suite indicate that 4 toilets/urinals each for men and women is adequate. One urinal is substituted for one toilet, and this is less than the 67% substitution allowed. Realistically, the office space would not generate 58 people; with 7 employees, that would allow each of them to have 7 visitors all at the same time, in addition to the 486 people accounted for in the warehouse. Therefore, we also figured the office area occupant load based on seat count, with 7 employees plus office guest chairs, conference room chairs and waiting seating. This results in an occupant load of 27 people in the office area, which seams more realistic. With 27 occupants in the office area, three lavs total each for men and women would be adequate. While the code does require that fractional totals for plumbing counts be rounded up; we are requesting that consideration be given to the realistic use of the space at 27 occupants in the office area and the fact that we are only 0.13 lav short under the calculations above for 56 people in the office area. TEMP STAIRS IN PLACE EXIT ON GRADE EXIT ON GRADE 24 9 ' - 1 1 " 13 ' - 1 " 38'-11" 19 7 ' - 1 1 " 25 0 ' - 0 " 13 ' - 1 " 25'-11" 21 1 ' - 0 " 24 7 ' - 1 " 22 ' - 1 0 " 163'-3" 61 ' - 0 " 24 9 ' - 1 1 " 23 ' - 6 " 153'-4" 73 ' - 1 " 166'-3" 24 9 ' - 9 " 13 ' - 3 " 23'-6" 21 3 ' - 0 " 24 9 ' - 1 0 " 13 ' - 5 " 46'-7" 18 9 ' - 1 0 " 24 9 ' - 4 " 12 ' - 5 " 39'-0" 19 7 ' - 1 1 " 22 7 ' - 2 " 23 ' - 4 " 139'-6" 64 ' - 4 " 17 9 ' - 9 " 24 ' - 3 " 69'-8" 85 ' - 1 0 " 25 0 ' - 0 " 14 ' - 1 " 32'-6" 20 3 ' - 5 " 24 9 ' - 1 1 " 14 ' - 6 " 40'-3" 19 5 ' - 2 " 20 0 ' - 7 " 23 ' - 0 " 106'-1" 71 ' - 6 " 25 0 ' - 0 " 17 ' - 2 " 38'-11" 19 3 ' - 1 0 " 25 0 ' - 0 " 17 ' - 6 " 45'-11" 18 6 ' - 8 " 24 9 ' - 1 1 " 16 ' - 8 " 39'-0" 19 4 ' - 3 " 25 0 ' - 1 " 17 ' - 3 " 24'-4" 20 8 ' - 6 " 24 9 ' - 1 1 " 17 ' - 4 " 24'-10" 20 7 ' - 9 " 25 0 ' - 1 " 48 ' - 4 " 152'-8" 49 ' - 1 " 25 0 ' - 2 " 18 ' - 2 " 39'-7" 19 2 ' - 5 " 25 0 ' - 1 " 17 ' - 5 " 32'-10" 19 9 ' - 1 0 " 24 9 ' - 1 1 " 17 ' - 9 " 35'-6" 19 6 ' - 8 " 24 9 ' - 1 1 " 48 ' - 3 " 155'-11" 45 ' - 9 " 20 7 ' - 9 " 48 ' - 8 " 109'-8" 49 ' - 5 " 22 5 ' - 0 " 48 ' - 4 " 138'-8" 37 ' - 1 1 " 25 0 ' - 0 " 48 ' - 7 " 167'-8" 33 ' - 9 " 24 9 ' - 1 0 " 17 ' - 4 " 24'-6" 20 8 ' - 0 " 24 9 ' - 1 0 " 18 ' - 1 " 17'-1" 21 4 ' - 7 " 25 0 ' - 1 " 25 0 ' - 1 " 24 9 ' - 1 0 " 47 ' - 6 " 171'-9" 30 ' - 7 " 25 0 ' - 0 " 48 ' - 8 " 182'-9" 18 ' - 7 " 25 0 ' - 1 " 17 ' - 3 " 9'-9" 22 3 ' - 0 " 24 9 ' - 1 1 " 17 ' - 7 " 4'-8" 22 7 ' - 8 " 24 9 ' - 6 " 17 ' - 2 " 19'-1" 21 3 ' - 2 " 25 0 ' - 0 " 48 ' - 2 " 187'-0" 14 ' - 1 0 " 250'-0" 48 ' - 4 " 201'-8"25 0 ' - 0 " 48 ' - 9 " 196'-4"4' - 1 1 " THESE LOCATIONS ARE VERY CLOSE TO BEING 250' MAX FROM AN EXIT AS SHOWN.THIS LOCATION IS VERY CLOSE TO BEING 250' MAX FROM AN EXIT AS SHOWN. THIS AREA IS NOT WITHIN 250' OF AN EXIT. ADD TEMP STAIRS AT THIS LOCATION.