HomeMy WebLinkAboutRiver Edge Blu Dot_TEMP EXITING_10-27-26BUILDING CODE: 2020 MINNESOTA BUILDING CODE (2018 IBC)
EXISTING BUILDING CODE:2020 MINNESOTA CONSERVATION CODE FOR EXISTING BUILDINGS
FUEL CODE:2020 MINNESOTA MECHANICAL AND FUEL GAS CODE
MECHANICAL CODE:2020 MINNESOTA MECHANICAL AND FUEL GAS CODE
PLUMBING CODE:2020 MINNESOTA PLUMBING CODE
ELECTRICAL CODE:2023 NATIONAL ELECTRICAL CODE
FIRE CODE:2020 MINNESOTA STATE FIRE CODE
ENERGY CODE: 2024 MINNESOTA ENERGY CODE
ACCESSIBILITY CODE:2020 MINNESOTA ACCESSIBILITY CODE
CITY:FRIDLEY COUNTY:ANOKA
APPLICABLE CODES
LIFE SAFETY PLAN LEGEND
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION
DISTANCE- COMMON PATH
OF TRAVEL
DISTANCE- EGRESS PATH
C1 11'-1"
E3 11'-1"
1. REFER TO ENGINEERING DRAWINGS FOR ALL EMERGENCY FIXTURES.
2. SMOKE AND FIRE RESISTANCE RATINGS SHOWN ARE MINIMUM RATINGS
REQUIRED. REFER TO PARTITION TYPES ON A9-2 FOR MORE INFORMATION.
3. SMOKE AND FIRE RESISTANCE RATINGS IN PARTITIONS ARE SHOWN WHERE
PARTITIONS ARE NOT CUT BY DOORS, WINDOWS, STOREFRONTS, OR OTHER
OBJECTS. RATED PARTITION MAY EXIST ABOVE OBJECTS.
FIRE EXTINGUISHER
NOTE: FIRE EXTINGUISHERS AT WAREHOUSE AREA
NOT SHOWN. PROVIDE FIRE EXTINGUISHERS AS
REQUIRED FOR MAXIMUM 75' TRAVEL DISTANCE TO
AN EXTINGUISHER
EXIT SIGN
LIFE SAFETY PLAN NOTES
FE
NOT IN CONTRACT (NIC)
DISTANCE TO RESTROOMS
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17
A
B
C
D
E
F
G
9
242931 SF
WAREHOUSES
AN-1
2
AN-1
3
207' -2"E4
A-B = 497' C-B = 531'
C-D = 498'
C
A-D = 600'
A
B
D
10 11
G
9
284 SF
ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED
363 SF
EXERCISE ROOMS
2421 SF
BUSINESS GENERAL
876 SF
ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED
29 SF
BUSINESS GENERAL
135 SF
ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED
CONFERENCE
102
EXERCISE ROOM
117
OFFICE
104
OFFICE
105
OFFICE
106
SERVER
107
WOMEN'S RESTROOM
110
MEN'S RESTROOM
111
STORAGE
116
JANITOR'S CLOSET
113
PRODUCT DISPLAY
103
OPEN OFFICE
108
WAITING
101
VESTIBULE
100
VENDING
114
HALL
112
EMPLOYEE LOUNGE
109
EMPLOYEE BREAK
115
63' -10"E2
114' -5"E1 61' -9"C1
90' -8"E3
FE
FE
A
9
472 SF
BUSINESS GENERAL
OCCUPANCY
SEPARATIONS:TYPE TO TYPE
REQUIRED
SEPARATION NOTES
OFFICE TO WAREHOUSE:B S-1 N
OFFICE TO ASSEMBLY: B A-3 N
SEE NOTE #6
SEE NOTE #6
ASSEMBLY TO WAREHOUSE:A-3 S-1 N SEE NOTE #6
1. NON-SEPARATED USES - OCCUPANCIES SEC. 508.3.
2. FIRE RATING REDUCED BY 1 HOUR FOR SPRINKLER SYSTEM (TABLE 508.4).
3. ACCESSORY AREAS OCCUPYING 10% OR LESS OF THE AREA OF ANY FLOOR AND NOT MORE THAN THE AREA OR
HEIGHT LISTED IN TABLES 504.3, 504.4 AND 506.2 ARE NOT REQUIRED TO BE SEPARATED (SEC. 508.2).
4. SQUARE FEET PER OCCUPANT DETERMINED BY TABLE 1004.5.
5. EXIT WIDTH DETERMINED BY SECTION 1005.3.
6. UNLIMITED AREA BUILDING PER MN BUILDING CODE SECTION 507.4.
SUITE CIRCULATION: COMPLIANT
SUITE DOOR CLEARANCES:
SUITE RESTROOMS:
SUITE SINKS:
WORKROOM MILLWORK:
COMPLIANT
COMPLIANT
COMPLIANT
N/ASUITE COAT CLOSETS:
N/A
PROVIDED/EXISTINGREQUIRED
NUMBER REQUIRED:2 22
EXIT SEPARATION:1/3 SUITE DIAGONAL COMPLIANT
EXIT WIDTH:(2) 32"(19) 34", (3) 68"
DOOR SWING DIRECTION:OUT OUT
EXIT ACCESS TRAVEL DISTANCE:A-3, S-1: ≤ 250'
B: ≤ 300'
COMMON PATH OF EGRESS DISTANCE:A-3: ≤ 75'
B, S-1: ≤ 100'
MAXIMUM DEAD-END CORRIDOR:≤ 50'
C1: 61'-9"
E1: 114'-5" E4: 207'-2"
E2: 63'-10"
E3: 90'-8"
N/A
PLUMBING FIXTURE ANALYSIS
NOTES BASED ON EMAIL EXCHANGES WITH TONY DEFORGE, BUILDING OFFICIAL, CITY OF
FRIDLEY:
1. SINCE THE BREAK ROOM AND EXERCISE ROOM ARE USED BY EMPLOYEES ONLY
AND ARE ACCESSORY USES TO THE S-1 OCCUPANCY, THESE ROOMS CAN BE
FIGURED AT 150 SF/OCCUPANT FOR PURPOSES OF PLUMBING CALCULATIONS.
2. MAXIMUM TRAVEL DISTANCE TO RESTROOMS CAN BE INCREASED FROM 500' TO NO
MORE THAN 600' IN THE WAREHOUSE AREA PER MN BUILDING CODE, EXCEPTION
TO SECTION 2902.3.3.
I hereby certify that this plan, specification or
report was prepared by me or under my direct
supervision and that I am a duly licensed
Architect under the laws of the State of
Minnesota
NORTH
Key Plan:
RELEASED FOR CONSTRUCTION
Reviewed By:Proj #:
Mary B. Hustad
17408
8/
2
6
/
2
0
2
6
4
:
3
5
:
4
1
P
M
A
u
t
o
d
e
s
k
D
o
c
s
:
/
/
R
i
v
e
r
E
d
g
e
B
u
s
i
ne
s
s
C
e
n
t
e
r
B
l
u
D
o
t
/
C
D
0
1
_
R
i
v
e
r
E
d
g
e
B
C
B
l
u
D
o
t
.
r
v
t
AN-1
LIFE SAFETY PLAN
2 OF 20
26.0001915.001 MBH
BLU DOT
RIVER EDGE BUSINESS CENTER
7350 COMMERCE LANE
FRIDLEY, MN 55432
1/32" = 1'-0"AN-1
LIFE SAFETY PLAN1
Nelson Architecture & Interiors, Inc.
901 Marquette Avenue South
Suite 2850
Minneapolis, MN. 55402
WWW.NELSONWORLDWIDE.COM
Phone: (612) 822-1211
1/8" = 1'-0"AN-1
ENLARGED OFFICE - LIFE SAFETY PLAN2
1/8" = 1'-0"AN-1
ENLARGED WAREHOUSE OFFICE - LIFE SAFETY PLAN3
LIFE SAFETY - OCCUPANCY
OCCUPANCY SEPARATIONS
NOTES
ACCESSIBILITY
LIFE SAFETY - EXITING
OCCUPANCY SCHEDULE
USE
OCCUPANCY
CLASSIFICATION AREA
LOAD FACTOR
(SF/PERSON)
CALCULATED
OCCUPANT LOAD
ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED B 284 SF 15 NET 19
ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED A-3 876 SF 15 NET 58
ASSEMBLY W/OUT FIXED SEATS UNCONCENTRATED B 135 SF 15 NET 9
BUSINESS GENERAL B 2,421 SF 150 16
BUSINESS GENERAL B 29 SF 150 0
BUSINESS GENERAL B 472 SF 150 3
EXERCISE ROOMS B 363 SF 50 7
WAREHOUSES S-1 242,931 SF 500 486
247,509 SF 599
Issue: No: Date:
ISSUE FOR PERMIT &
CONSTRUCTION
08/26/2026
PLUMBING CALCULATIONS AS ACCEPTED BY TONY DEFORGE:
The multistall restrooms in the office area are used both by office and warehouse employees. The break room and gym are figured at 150 sf/occupant for
plumbing calculations, since these spaces are used by employees already accounted for. Plumbing calculations are as follows:
Warehouse: 486 people; 243 men/243 women. Required toilets (1:100): 2.43 each; required lavs (1:100): 2.43 each.
Office: 56 people; 28 men/28 women. Required toilets (1:25 for first 50; 1:50 thereafter): 1.12 each; required lavs (1:40 for first 50; 1:80 thereafter): 0.70 each
Total toilets required each, men and women: 2.43 + 1.12 = 3.55. Round up to 4 each.
Total lavs required each, men and women: 2.43 + 0.70 = 3.13. Round up to 4 each.
MN Building Code section 2902.1.1 states that “For calculations involving multiple occupancies, such fractional numbers for each occupancy shall first be summed
and then rounded up to the next whole number.” Totals are consistent with this method.
Calculations based on figuring the break/lounge and gym at 150 sf/occupant since those spaces are not adding people to the suite indicate that 4 toilets/urinals
each for men and women is adequate. One urinal is substituted for one toilet, and this is less than the 67% substitution allowed. Realistically, the office space
would not generate 58 people; with 7 employees, that would allow each of them to have 7 visitors all at the same time, in addition to the 486 people accounted
for in the warehouse. Therefore, we also figured the office area occupant load based on seat count, with 7 employees plus office guest chairs, conference room
chairs and waiting seating. This results in an occupant load of 27 people in the office area, which seams more realistic. With 27 occupants in the office area, three
lavs total each for men and women would be adequate. While the code does require that fractional totals for plumbing counts be rounded up; we are requesting
that consideration be given to the realistic use of the space at 27 occupants in the office area and the fact that we are only 0.13 lav short under the calculations
above for 56 people in the office area.
TEMP STAIRS
IN PLACE
EXIT
ON
GRADE
EXIT
ON
GRADE
24
9
'
-
1
1
"
13
'
-
1
"
38'-11"
19
7
'
-
1
1
"
25
0
'
-
0
"
13
'
-
1
"
25'-11"
21
1
'
-
0
"
24
7
'
-
1
"
22
'
-
1
0
"
163'-3"
61
'
-
0
"
24
9
'
-
1
1
"
23
'
-
6
"
153'-4"
73
'
-
1
"
166'-3"
24
9
'
-
9
"
13
'
-
3
"
23'-6"
21
3
'
-
0
"
24
9
'
-
1
0
"
13
'
-
5
"
46'-7"
18
9
'
-
1
0
"
24
9
'
-
4
"
12
'
-
5
"
39'-0"
19
7
'
-
1
1
"
22
7
'
-
2
"
23
'
-
4
"
139'-6"
64
'
-
4
"
17
9
'
-
9
"
24
'
-
3
"
69'-8"
85
'
-
1
0
"
25
0
'
-
0
"
14
'
-
1
"
32'-6"
20
3
'
-
5
"
24
9
'
-
1
1
"
14
'
-
6
"
40'-3"
19
5
'
-
2
"
20
0
'
-
7
"
23
'
-
0
"
106'-1"
71
'
-
6
"
25
0
'
-
0
"
17
'
-
2
"
38'-11"
19
3
'
-
1
0
"
25
0
'
-
0
"
17
'
-
6
"
45'-11"
18
6
'
-
8
"
24
9
'
-
1
1
"
16
'
-
8
"
39'-0"
19
4
'
-
3
"
25
0
'
-
1
"
17
'
-
3
"
24'-4"
20
8
'
-
6
"
24
9
'
-
1
1
"
17
'
-
4
"
24'-10"
20
7
'
-
9
"
25
0
'
-
1
"
48
'
-
4
"
152'-8"
49
'
-
1
"
25
0
'
-
2
"
18
'
-
2
"
39'-7"
19
2
'
-
5
"
25
0
'
-
1
"
17
'
-
5
"
32'-10"
19
9
'
-
1
0
"
24
9
'
-
1
1
"
17
'
-
9
"
35'-6"
19
6
'
-
8
"
24
9
'
-
1
1
"
48
'
-
3
"
155'-11"
45
'
-
9
"
20
7
'
-
9
"
48
'
-
8
"
109'-8"
49
'
-
5
"
22
5
'
-
0
"
48
'
-
4
"
138'-8"
37
'
-
1
1
"
25
0
'
-
0
"
48
'
-
7
"
167'-8"
33
'
-
9
"
24
9
'
-
1
0
"
17
'
-
4
"
24'-6"
20
8
'
-
0
"
24
9
'
-
1
0
"
18
'
-
1
"
17'-1"
21
4
'
-
7
"
25
0
'
-
1
"
25
0
'
-
1
"
24
9
'
-
1
0
"
47
'
-
6
"
171'-9"
30
'
-
7
"
25
0
'
-
0
"
48
'
-
8
"
182'-9"
18
'
-
7
"
25
0
'
-
1
"
17
'
-
3
"
9'-9"
22
3
'
-
0
"
24
9
'
-
1
1
"
17
'
-
7
"
4'-8"
22
7
'
-
8
"
24
9
'
-
6
"
17
'
-
2
"
19'-1"
21
3
'
-
2
"
25
0
'
-
0
"
48
'
-
2
"
187'-0"
14
'
-
1
0
"
250'-0"
48
'
-
4
"
201'-8"25
0
'
-
0
"
48
'
-
9
"
196'-4"4'
-
1
1
"
THESE LOCATIONS ARE VERY
CLOSE TO BEING 250' MAX
FROM AN EXIT AS SHOWN.THIS LOCATION IS VERY
CLOSE TO BEING 250' MAX
FROM AN EXIT AS SHOWN.
THIS AREA IS NOT
WITHIN 250' OF AN EXIT.
ADD TEMP STAIRS AT
THIS LOCATION.